Technical Data - Graco 226040 Instructions-Parts List Manual

2:1 ratio standard pump
Hide thumbs Also See for 226040:
Table of Contents

Advertisement

Category
Maximum fluid working pressure
Air input pressure operating range
Pump cycles per 1 gallon (3.8 liters)
Maximum recommended pump speed for
continuous operation
Air consumption
Maximum Ambient temperature for T6
hazardous location use
Maximum operating temperature of fluid
pump
Maximum operating temperature of air
motor
Wetted parts
20
307026

Technical Data

Data
360 psi (25 bar)
30-180 psi (2-12 bar)
40 (50 for Model 223954)
100 cycles per min
approx. 3 scfm (0.09 m#/min) at 1 gpm (3.8 liters/min) at 100 psi (7
bar) air pressure
120_F (50_C)
480_F (248_C) for non–hazardous location applications only
280_F (138_C) for non–hazardous location applications only
Stainless Steel, PTFE, Polyetheretherketone (PEEK)