Clasp the filter buckle by hand, press down and pull out
6.2
Check Valve and Fan Cover Mounting and Dismounting
Step: as shown in the picture, hold the check valve or fan cover respectively, rotate until the blade
rotated to the vacant position from the board, then, the check valve or fan cover can be taken
down.
6.3
Dismantle Spotlight
Tool: Cross screwdriver
Step: first remove the transparent lamp panel in the front, then hold the incandescent lamp and rotate
inward, take out the bulb, as shown in the following picture.
- -