As shown in the picture, press the button indicated by the red arrow, smoke exhaust function of large airflow
is on; press the button indicated by the yellow arrow, switched to smoke exhaust function of middle airflow;
press the button indicated by the green arrow, switched to smoke exhaust function of small airflow; press the
button indicated by the brown arrow, all smoke exhaust functions except lamp are cancelled. All smoke
exhaust function buttons will be auto reset.
3.2.2
Toggle Switch
As shown in the picture, the button indicated by the red circle is toggle switch smoke exhaust control
button, 0,1,2,3 respectively indicate stop, low speed, middle speed and high speed; toggle the switch to the
left and right, the airflow and switch of range hood can be switched freely.
Note: please refer to the User Manual for the specific operation steps of hood function

Circuit Diagram

4.
Note: the above is the circuit diagram of basic models, please be subject to the circuit diagram in
product instruction book if there is difference.

Installation

5.
5.1

Preparation before Installation

1. Please remove the package first, then install according to the dimension in the following instruction;
(Please dispose the packaging material properly)
2. No inflammable, explosive or non-heat-resistant article should contact or approach around the range
hood.
3. The wall where the hood is hung should have sufficient strength and flatness to ensure that the product
has adequate stability.
- -