Thermo Scientific AutoPILOT PRO User Manual page 127

Six-run gas flow computer & remote telemetry unit
Table of Contents

Advertisement

Specifications
B-2
AutoPILOT PRO Flow Computer User Guide
IECEx
CSA
ATEX with AutoMITTER
SIB option
ATEX without
AutoMITTER SIB option
Brazil (INMETRO)
FCC
Electromagnetic
Compatibility
Table B–3. I/O expansion
2-DI/DO MEB
Maximum of 6 boards per unit.
DI: Provides 2 contact inputs with internal +5 Vdc wetting voltage.
DO: Provides 2 open drain FET output contact closures, externally
powered. Rated at +30 Vdc / 250 mA maximum.
4-DI MEB
Maximum of 6 boards per unit.
Provides 4 contact inputs with internal +5 Vdc wetting voltage.
4-DO MEB
Maximum of 6 boards per unit.
Provides 4 open drain FET output contact closures, externally
powered. Rated at +30 Vdc / 250 mA maximum.
2-PI MEB
Maximum of 4 boards per unit.
Provides 2 pulse inputs configurable for slot sensor, magnetic pick-
up, or dry contact inputs. Maximum 10 KHz.
2-D/A (Dual Analog
Maximum of 4 boards per unit.
Output) MEB
Provides 2 outputs, 1–5 V or 4–20 mA. Powered by battery or
external +24 Vdc.
AI Expansion
Expansion option consists of 1 AI expansion board and up to 4 AI
terminal boards. Each terminal board provides 4 inputs with 14-bit
resolution, 0–5 V.
Current input 4–20 mA can be converted to voltage input by an
external 250-ohm resistor.
Full scale ± 0.1% over operating temperature range.
IECEx CSA 13.0030X
Ex nA IIB T4 Gc
Ex nA [ia, Ga] IIB T4 Gc
-40°C to +80°C
Class I, Div. 2, Groups C & D, T3C (Tamb -40°C to +85°C)
EPSILON 08 ATEX 2440X
II 3 (1) G Ex nL [ia] IIB T4
(Tamb -40°C to +80°C)
EPSILON 08 ATEX 2440X
II 3 G Ex nL IIB T4
(Tamb -40°C to +80°C)
TÜV 11.0076X
Ex nL IIB T4 Gc
-40°C ≤ Ta ≤ +80°C)
47CFR part 15, Class A
Compliant with EN 61326-1: 2006