Thermo Scientific Orion Star A216 Benchtop Reference Manual

Ph/rdo/do meters
Hide thumbs Also See for Orion Star A216 Benchtop:
Table of Contents

Advertisement

Quick Links

Thermo Scientific Orion Star A216 Benchtop
and Star A326 Portable pH/RDO/DO Meters
Reference Guide

Advertisement

Table of Contents
loading

Summary of Contents for Thermo Scientific Orion Star A216 Benchtop

  • Page 1 Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meters Reference Guide...
  • Page 2 Ross and the COIL trade dress are trademarks of Thermo Fisher Scientific, Inc. and its subsidiaries. AQUAfast, AQUASensors, BOD AutoEZ, ionplus, KNIpHE, LogR, No Cal, ORION, perpHect, PerpHecT, pHISA, pHuture, Pure Water, Sage, ROSS, ROSS Ultra, Sure-Flow, Titrator PLUS, and TURBO2 are registered trademarks of Thermo Fisher Scientific, Inc.
  • Page 3: Table Of Contents

    Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meters Chapter 1 Introduction ............1 Chapter 2 Meter Overview.
  • Page 4 Chapter 9 Data Storage and Retrieval ..........31 Data Storage Settings .
  • Page 5 This page intentionally left blank.
  • Page 6: Chapter 1 Introduction

    Chapter 1 Introduction Thank you for your purchase of the Orion Star A216 benchtop pH/RDO/DO or Star A326 portable pH/RDO/DO meter. These meters are capable of measuring pH, mV, relative mV (RmV), ORP, dissolved oxygen and temperature in °C or °F.
  • Page 7 This page intentionally left blank. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 8: Chapter 2 Meter Overview

    (use a coin or your finger) and release the bottom portion of the battery cover. Orion Star A Series Benchtop Orion Star A Series Portable battery cover Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 9: Electrodes And Other Connections

    Star A216 Meter Back Panel ATC/ COND POWER RS232 Star A326 Meter Back Panel Orion Star A216 benchtop meters only. Orion Star A216 benchtop meters only. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 10: Connecting Electrode The Benchtop Meter

    Orion Star A series benchtop meters include an electrode arm that can be attached to either side of the meter. 2. Choose the side of the meter to attach the arm. should be on the same side as the meter display. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 11: Meter Display

    RDO/DO modes only. Salt: 0.0 Displays the salinity correction factor used to correct dissolved oxygen measurements. RDO/DO modes only. is pressed. is pressed. sample ID is pressed. channel Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 12: Meter Keypad

    (unfreeze) the measurement. Orion Star A216 benchtop meters only. Press to start or stop the stirrer probe. Orion Star A216 benchtop meters only. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 13: Meter Maintenance

    (frozen), only the 6. Press Orion Star A216 benchtop meters only. to access the calibration log and data log. Orion Star A216 benchtop meters only. Meter Maintenance meter using the proper cleaning procedure for the type of spill.
  • Page 14: Chapter 3 Meter Setup

    Channel DO/RDO Channel Settings Log View Diagnostics Method Method Mode & Settings Mode & Settings (Star A216 meters only) Temperature (RDO only) Temperature Calibration Calibration Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 15: Ph Channel Menu

    Menu used to select the resolution for the displayed measurement values. Menu used to select the buffer group used for automatic buffer recognition during pH calibrations. Buffer Group Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 16 DO probe, Temperature Calibration Temperature membrane temperature measured by a DO probe or a combination of these to be adjusted by the operator. Temperature Mem Temp Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 17: Do/Rdo Channel Menu

    Menu used to set manual salinity correction for dissolved oxygen Salinity Correct Manual Stability values is indicated. Smart Stability automatically compensates for measurement conditions and optimizes the meter response time. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 18 Menu used to select the temperature units. Temperature Calibration Temperature membrane temperature measured by a DO probe or a combination of these to be adjusted by the operator. Temperature Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 19: Settings Menu

    Menu used to set the language for all displayed meter prompts. Menu used to turn on or off the beep sound made every time a meter key is pressed. Alarm Beep Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 20: View Log Menu

    ID) and using the alphanumeric entry screen. View Log Menu Storage and Retrieval chapter for detailed information on using this setup menu. Diagnostics Menu detailed information on using this setup menu. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 21 This page intentionally left blank. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 22: Chapter 4 Ph, Rmv And Orp Calibration

    (meas) to proceed to the measurement mode or press f2 (print) to proceed to the measurement mode and export the data to a printer or computer. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 23: Calibration Editing

    Press f1 (meas) to proceed to the measurement mode or press f2 (print) to proceed to the measurement mode and export the data to a printer or computer. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 24: Orp Calibration

    Press f1 (meas) to proceed to the measurement mode or press f2 (print) to proceed to the measurement mode and export the data to a printer or computer. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 25 This page intentionally left blank. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 26: Chapter 5 Rdo/Do Calibration

    102.3 % if using a polarographic DO probe. 6. Press f3 (cal done) to export the data to the calibration log or press f2 (print) to export the data to the calibration Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 27: Water Dissolved Oxygen Calibration

    Reading is stable. Accept Auto Calibration Value and 100 %. 6. Press f3 (cal done) to export the data to the calibration log or press f2 (print) to export the data to the calibration Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 28: Manual Dissolved Oxygen Calibration

    Press f2 (accept) to accept the entered dissolved oxygen value. 6. Press f3 (cal done) to export the data to the calibration log or press f2 (print) to export the data to the Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 29: Set Zero Dissolved Oxygen Calibration

    Reading is stable. Accept Auto Calibration Value and 0.00. 6. Press f3 (cal done) to export the data to the calibration log or press f2 (print) to export the data to the Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 30: Chapter 6 Temperature Calibration

    (meas) to proceed to the measurement mode or press f2 (print) to proceed to the measurement mode and export the data to a printer or computer. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 31 This page intentionally left blank. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 32: Chapter 7 Measurement

    Star A216 meters only to turn off the stirrer probe. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 33 This page intentionally left blank. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 34: Chapter 8 Methods

    (M101) and the date, time and mode of each method (07/01/11 12:45 pH) if methods have been previously created. to highlight the method to be loaded and press f2 (load). Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 35: Editing, Copying Or Deleting An Existing Method

    (accept) measurement mode. Delete is selected – press f2 (yes) to delete the method or press f3 (no) to keep the method. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 36: Chapter 9 Data Storage And Retrieval

    (HH), minutes (MM) or seconds (SS); press f3 (edit) to access the numeric entry screen; use the numeric entry screen to change the values and press f1 (back) 6. Press to return to the measurement mode. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 37: Computer And Printer Export Settings

    Data Log and press f3 (select). to highlight Off or On and press f3 (select). f1 (back) and then press to return to the measurement mode. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 38: Viewing The Calibration Log And Data Log

    (select). Press f2 (print) to print the data point or press f1 (back) to return to the list of data points. to return to the measurement mode. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 39: Exporting The Data Log To A Computer Or Printer

    (enter) to select the highlighted vii. Press f2 (done) to exit the numeric entry screen. viii. Press f2 (accept) and then press f2 (yes) to export the data. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 40: Clearing The Data Log

    Log Clear and press f2 (accept). f2 (yes) 111111 and pressing f2 (accept) f1 (back) and then press to return to the measurement mode. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 41: Interfacing A Printer

    A complimentary copy of general data logging software is available for use with the Orion Star A200 and Star A300 series meters. This can be found on the CD included with the meter or at www.thermoscientific.com/water. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 42: Chapter 10 Customer Services

    Make sure that the electrode is connected to the appropriate meter input and the electrode Measurement Out of Range parameters are entered correctly in the setup menu. Clean the electrode according to the electrode Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 43: Meter Self Test And Checkout

    ) one at a time in any order. When the meter displays Keypad Test Passed, press f2 (next). Self Test Passed. Press to return to the measurement mode. Meter Checkout (pH) Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 44: Electrode Stability Test

    Meter Factory Reset 2. Press to highlight Diagnostics and press f3 (select). 3. Press to highlight Factory Reset and press f2 (accept). f2 (yes) to reset the meter. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 45: Meter User Reset

    About Meter and press f2 (accept). f1 (back) to return to the diagnostics menu or press to return to the measurement mode. Assistance Warranty and Registration Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 46: Ordering Information

    Orion Star A200 Series Benchtop Meters Cat. No. Description STARA2110 STARA2115 STARA2120 STARA2125 STARA2126 STARA2130 STARA2135 STARA2136 STARA2140 STARA2145 STARA2146 Storage Solution STARA2147 STARA2148 STARA2150 STARA2155 Standard STARA2160 STARA2165 Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 47 Star A322 Conductivity Portable Meter STARA3225 STARA3230 Star A323 RDO/DO Portable Meter STARA3235 STARA3240 STARA3245 STARA3250 STARA3255 Star A Meter Armor STARA3260 Star A326 pH/RDO/DO Portable Meter STARA3265 STARA3290 STARA3295 Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 48 8157BNUMD 8107UWMMD 927005MD 927007MD Stainless Steel ATC Probe 9179BNMD 9180BNMD 9512HPBNWP 9609BNWP 8611BNWP 013005MD 013010MD 013020MD 013025MD 013016MD 083005MD 083010MD 083025MD 086030MD 087010MD 087020MD 087030MD 096019 Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 49 This page intentionally left blank. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 50: Chapter 11 Meter Compliance

    (de la class A) prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des WEEE Compliance the recyclers in your country, and information on Thermo Scientific Orion products that may assist the detection of Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 51: Declaration Of Conformity

    Conforms with the following directives and standards: EN61326-1:2006 Electromagnetic Compatibility (EMC Directive) EN61010-1:2001 Safety Standards UL61010-1:2004 Safety requirements for electrical equipment for measurement, CAN/CSA C22.2 No. 61010-1-04 QA/Regulatory Manager Singapore Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 52: Meter Specifications

    Shock and Vibration Warranty 3 year meter replacement Universal Power Adapter Operating Conditions Operating Ambient Temperature Operating Relative Humidity Storage Temperature Storage Relative Humidity Pollution Degree 2 Overvoltage Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 53 ORP Mode Dissolved Oxygen Measurement Concentration - Polarographic Range Resolution Relative Accuracy % Saturation - Polarographic Range Resolution Relative Accuracy Concentration - RDO Range Resolution Relative Accuracy Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 54 Range Resolution Relative Accuracy Offset Calibration 1 point Data Logging Delete individual points, group of points or all Inputs ATC Probe Probe Output Power AC Adapter Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 55 This page intentionally left blank. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 56: Appendix 1 Advanced Meter Features

    Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 57: Electrode Condition Icon

    The electrode condition icon indicates the performance of the pH electrode, based on the last saved calibration and electrode measurement stability. Icon pH Electrode Definition of Icon troubleshoot the electrode. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 58: Multipoint Calibration Curve Feature

    The meter can also use manual barometric pressure compensation if as mm Hg. 1 mm Hg = 0.03937 inch Hg = 1.3332 hPa (mBar) = 0.01934 PSI. Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 59: Dissolved Oxygen Salinity Correction

    Salinity Conductivity Salinity Conductivity Salinity at 20 °C Correction at 20 °C Correction at 20 °C Correction (mS/cm) Value (ppt) (mS/cm) Value (ppt) (mS/cm) Value (ppt) Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable pH/RDO/DO Meter Reference Guide...
  • Page 60 This page intentionally left blank.
  • Page 61 Water Analysis Instruments North America 9 0 0 1 : 2 0 0 8 166 Cummings Center Beverly, MA 01915 USA Toll Free: 1-800-225-1480 Tel: 1-978-232-6000 info.water@thermo.com Netherlands Tel: (31) 033-2463887 info.water.uk@thermo.com India Tel: (91) 22-4157-8800 wai.asia@thermofisher.com Japan Tel: (81) 045-453-9175 wai.asia@thermofisher.com China Tel: (86) 21-68654588...

This manual is also suitable for:

Orion star a326 portable

Table of Contents