Do you have a question about the Luna Diamond Series and is the answer not in the manual?
Questions and answers
ΚΟΣΜΙΝΑ ΠΟΠΕΣΚΟΥ
January 31, 2025
Γιατι εμφανιστηκε !F08 και το τζακι δεν αναβει
1 comments:
Mr. Anderson
May 14, 2025
The provided context does not mention error code F08 specifically, so its exact meaning cannot be determined directly from the information given. However, we can infer potential causes for ignition issues based on related information in the manual:
1. Air-Fuel Mixture Issues: The flame color (blue turning yellow or burning yellow too quickly) indicates problems with combustion—either too much or too little air. If the air intake is not properly adjusted, the gas may not ignite or burn correctly, which can prevent ignition.
2. Improper Convection Setup: The manual states that error code F02 appears when proper convection (air circulation using flexible hoses and vents) is not installed. While not directly related to F08, this suggests that system errors are triggered by improper installation or airflow. F08 might similarly relate to another installation or airflow fault that prevents ignition.
3. Electronic Component Overheating or Protection Lockout: If the appliance is not set up with proper spacing (not on the floor, openings not connected with hoses), electronic components could overheat, which might trigger a system lockout and prevent ignition.
### Conclusion: While F08 is not defined in the given context, the fireplace may fail to ignite due to incorrect air intake adjustment, poor combustion, or improper convection setup. Ensuring the air-fuel mix is correct, the convection kit is properly installed, and the unit is elevated with airflow openings connected is crucial for proper ignition and avoiding error codes.
Would you like me to try to find the official definition of F08 from the full manual?
Summary of Contents for M Design Luna Diamond Series
Page 1
LUNA DIAMOND GAS 1000-1150-1300-1600-1900 DH-CL-CR-DC INSTRUCTIONS FOR INSTALLATION AND USE 11-2019 Instructions for installation and use DIAMOND Gas DH-CL-CR-DC...
Page 2
V E R Y I M P O R T A N T I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E M - D E S I G N G G A S F I R E P L A C E S T H E S U P P L I E R T A K E S N O R E S P O N S B I L I T Y F O R A N Y P O S S I B L E D A M A G E , P O O R W O R K I N G A P P L I A N C E S A N D...
SUMMARY 1. GENERAL REMARKS ............2. CONNECTION ..............3. INSTALLING THE FIREPLACE ..........3.1.1 Positioning the fireplace ..........3.1.2 Nearbox (Gasunit) ............3.1.3 The Gas connection ............ 3.1.4 Electrical connection ............ 3.1.5 Modification natural gaz to propane ......4. INSTALLING THE CHIMNEY ..........10-13 5.
Page 4
OPEN EN CLOSE THE DOOR For initial setup, you need to clean the window and clear the fireplace of any dust and grease that is left behind. This is also the only maintenance action that may be performed on the device by the user. Thanks to a patented system, the door can be easily opened at an angle of 45°...
1. General remarks This is an appliance using the closed combustion system, designed for the atmosphere and comfort of your living-room. It constitutes an efficient source of heat and gives the impression of a real fire. The balanced flue appliances are based on the principle of natural extraction from the firebox, which eliminates flue gas outside and brings in air (oxygen) from outside the house which is necessary for combustion of the gas.
3. Installing the fireplace After having checked the appliance, you are ready to install your appliance. This is done as follows 3.1.1 Positioning the appliance Place the appliance on a stable surface using the adjustable feet. Adjust the height of the appliance turning the bolt ( pic 1 ) The appliance must not be placed directly on the floor as you need to allow natural convection.
3.1.2 Nearbox (gasunit) For safety reasons, The gasbattery or “NEARBOX” is fixed with screws at the rear of the unit during transport . THE UNIT CANNOT BE INSTALLED WITH THIS NEARBOX FIXED AT THE REAR, IT IS MAN- DATORY TO UNSCREW THE BATTERY FROM THE REAR PRIOR TO INSTALLATION . unscrew 4 screws in the corners (key 8) to second burner or side burner...
3.1.3 The Gas connection After the “NEARBOX” has removed from the of the back of the fire, you can place it loosely on the ground in proximity to the opening provided in the wall of mantelpiece. The device is always con- nected with an approved gas tap 1/2, and preferably with a yellow gasflexible that is reachable at all times.
3.1.4 Electrical connection These appliances are equipped with a radiographic remote control, making an earthened 220V socket necessary. You should bear in mind that the appliance must be connected to all electrical supplies for the purposes of service. It’s obligatory to connect an earth current. 3.1.5 Modification natural gaz to propane Modification of the fireplace can only be done by the manufacturer or an approved installer.
4. Installing the chimney Install the concentric flue duct as indicated by ONTOP - METALOTERM. The only authorised pipes are ONTOP Metaloterm™. ONTOP-METALOTERM tested our appliances with their conduct and we only guarantee a good working of the appliance with those. Between the external wall of the pipe and the wall or the ceiling, you should allow for a clearance of at least 50mm and protection that is suitable against temperatures of around 130°C.
Page 11
Picture 2: ROOF EXIT VIA EXISTING CHIMNEY (C91S) Ø 150 (min) / Ø 100 Ø 150 (min) / Ø 100 Appliance C (min) C (max) Restriction (as from 4m) 1000 DH / CL / CR / DC Ø 60 1 150 DH Ø...
Page 12
Picture 3: WALL EXIT (C11) Picture 3 Ø 150/100 Ø 150/100 With reduction usvk 13 on appliance (picture 3 ) Appliance A (min) B (min) B (max) Restriction 1000 DH / CL / CR / DC 1,25*m Wall Exit =A+0,5m Ø...
Picture 4: ROOF EXIT WITH BEND Ø 150/100 Ø 150/100 With reduction usvk 13 on appliance Appliance A (min) B (max) C (min) (A+B+C )max 1000 DH / CL / CR / DC 1,25* m B-A-1m 1 150 DH 1,25* m B-A-1m 1300 DH / CL / CR / DC 1,25* m...
Attention, burner have to burn continuously evenly in the whole length included secondary burners. of hot air. For insulation of the appliance, we advise you to use M Design insulating By adjusting the flame cannot remove up from burner (cannot be plates.
7. Convenction current Please, follow this instructions. The appliance can overheat if you not apply those instructions. Errorcode F02 will appear! It is MANDATORY to equip the fireplace with a convection kit consisting of inlets and outlets which are connected to stretchable hoses from 3m to 5m. In this way is created a circualtion and evacuation of the heat by convection.
Page 16
Instructions for installation and use DIAMOND Gas DH-CL-CR-DC...
Page 17
You have to connect at least two appertures situated at the top of the appliance. For the Luna 1600, you must connect 4 appertures. The appliance may not be placed directly on the floor, without the feet. This is to allow natural convection. The appertures for the air supply are situated underneath the aplliance Every opening you make must be connected with a flexible tube dia 150MM (see pic below).
8. Positioning the logs, diamond, sapphire and white pebbles Please check that the pilot light is switched off and that the appliance has cooled down. • Move the window to the front by pulling it. The window tips open at 45°. •...
Page 19
Luna 1000DH/CL/CR/DC Gas Instructions for installation and use DIAMOND Gas DH-CL-CR-DC...
Page 20
Luna 1150DH Gas Instructions for installation and use DIAMOND Gas DH-CL-CR-DC...
Page 21
Luna 1300DH/CL/CR/DC Gas Luna 1300H Gas Instructions for installation and use DIAMOND Gas DH-CL-CR-DC...
Page 22
Luna 1600 DH/CL/CR/DC Gas Instructions for installation and use DIAMOND Gas DH-CL-CR-DC...
Page 23
Luna 1900DH Gas Instructions for installation and use DIAMOND Gas DH-CL-CR-DC...
The appliance must not be used if the door no longer has a window or with the door open. If the window is broken or cracked, the appliance must not be used until the window has been replaced. Contact your M Design reseller. 10. Safety, device and maintenance Have your appliance inspected every 2 years by a qualified technician.
11. Guarantee This page is your warranty card. The guarantee is only valid for faults caused by construction defects or defects in the parts used to build the appliance. M-Design offers a 12 month guarantee on all electronic parts and a 8 year guarantee on the appliance construction.
12. Remote control (direct ingnition) 1. First use (Connect the remote control) Keep pressing the button until 24:00 appears in the top left corner (1). Press several times on until you see “bnd” on the screen (2) Press shortly on You see the temperature on the screen.
Page 27
4. Manual control (Triple Line Burner) To light up the side burners 2, press First you see the wave settings (page 30). Press a second time and you will see a “b0” or “b0” Remark: If after a previous use of the fireplace, you turned it off in “b1” mode, next ignition, the burners 1,2 and 3 will light simultaneously.
Page 28
5. Thermostatic control In case you want to go to a thermostatic control, you follow the next steps: Press 2x the button until you see the screen with the symbols shown in picture 2. Press until the symbols are blinking (pic 2). Confirm your choise by pressing ( pic.3).
Need help?
Do you have a question about the Luna Diamond Series and is the answer not in the manual?
Questions and answers
Γιατι εμφανιστηκε !F08 και το τζακι δεν αναβει
The provided context does not mention error code F08 specifically, so its exact meaning cannot be determined directly from the information given. However, we can infer potential causes for ignition issues based on related information in the manual:
1. Air-Fuel Mixture Issues: The flame color (blue turning yellow or burning yellow too quickly) indicates problems with combustion—either too much or too little air. If the air intake is not properly adjusted, the gas may not ignite or burn correctly, which can prevent ignition.
2. Improper Convection Setup: The manual states that error code F02 appears when proper convection (air circulation using flexible hoses and vents) is not installed. While not directly related to F08, this suggests that system errors are triggered by improper installation or airflow. F08 might similarly relate to another installation or airflow fault that prevents ignition.
3. Electronic Component Overheating or Protection Lockout: If the appliance is not set up with proper spacing (not on the floor, openings not connected with hoses), electronic components could overheat, which might trigger a system lockout and prevent ignition.
### Conclusion:
While F08 is not defined in the given context, the fireplace may fail to ignite due to incorrect air intake adjustment, poor combustion, or improper convection setup. Ensuring the air-fuel mix is correct, the convection kit is properly installed, and the unit is elevated with airflow openings connected is crucial for proper ignition and avoiding error codes.
Would you like me to try to find the official definition of F08 from the full manual?