Commissioning Procedure; Commissioning Files - Siemens SINUMERIK 828D Manual

Output of setpoints to analog drives - retrofit solution
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

3 Commissioning
3.2.1

Commissioning procedure

Observe the Requirements.
Reset the SINUMERIK 828D to the factory settings using the drive wizard.
Load the commissioning files to achieve the following:
In the SINAMICS HLA, specific data of the internally used, purely fictitious
closed-loop hydraulic control are preassigned in order to avoid alarms.
All internal controllers of the SINAMICS HLA are deactivated.
3.2.2

Commissioning files

The commissioning files consist of an ACX or TEA file, both of which have the file
name "TTL_1024_SW_4_8".
You can use the files for linear and rotary axes. As soon as a TTL encoder that
supplies 1024 pulses per revolution is connected to both on-board interfaces, the
analog axis is immediately ready for operation.
If an SSI encoder, or sin/cos/EnDat encoder via SMC/SME, or a DRIVE-CLiQ
encoder is connected, you must adapt the encoder data in the commissioning
wizard.
Loading the commissioning files
Note
Create a NC/PLC/DP archive before you load the commissioning files.
Note
The procedure for loading the commissioning files is identical to that of a purely
electrical SINAMICS drive.
Load the commissioning files from a USB flashdrive:
Press the <MENU SELECT> key.
Open the "Setup" area.