Install second row of shingles Á ush at top of À rst row's rain slots. Ensure 1" overhang or Á ush to drip edge at front,
3
stagger each row.
FRONT OF
SHED
1"
(2,5 cm)
Notch
Flush with rain slots.
4
Continue installing rows of
shingles by staggering at front.
FRONT OF
5
Continue installing rows of shingles to the peak. At the peak make sure there is a maximum of 5" or less to the rain slot, as
shown below. If shingles overlap at ridge cut to peak with a utility knife.
Cut Off.
• If more than 5" to rain slot you must install another row of shingles.
6
Repeat steps 1 - 5 to shingle the opposite side of your roof. Trim shingles at ridge.
7
Once both sides are shingled you need to trim ends. Strike a chalk line 1" from edge.
8
Using your shingle hooked blade carefully cut shingles along chalk line.
FINISH
9
You have À nished shingling your roof. Proceed to capping the ridge.
SHINGLES
1"
(2,5 cm)
SHED
Notch
5"
(12,7 cm) MAX.
Top of rain slot.
continued...
CUT
29
BACK OF
SHED
Flush with rain slots.