Pc based automation, global drive control gdc, industrial pc as gateway (12 pages)
Summary of Contents for Lenze EL 1800
Page 1
Controls EDSIPCx7 L−force .N+_ System Manual Industrial PC Embedded Line (EL), Command Station (CS), Cabinet PC (CPC), L−force Controller 3241 C System structure and configuration...
13348653 10/2010 TD31 Change of generation from x700 series to x800 series 13300002 06/2009 TD14 First edition Tip! Information and auxiliary devices related to the Lenze products can be found in the download area at http://www.Lenze.com EDSIPCx7 EN 4.1...
About this documentation Conventions used Conventions used This documentation uses the following conventions to distinguish between different types of information: Spelling of numbers Decimal separator Point In general, the decimal point is used. For instance: 1234.56 Text Program name » « PC software For example: »Engineer«, »Global Drive Control«...
About this documentation Notes used Notes used The following pictographs and signal words are used in this documentation to indicate dangers and important information: Safety instructions Structure of safety instructions: Danger! (characterises the type and severity of danger) Note (describes the danger and gives information about how to prevent dangerous situations) Pictograph and signal word Meaning...
The manufacturer does not accept any liability for the suitability of the specified procedures and circuit proposals. Only qualified skilled personnel are permitted to work with or on Lenze drive and ƒ...
Page 8
Safety instructions General safety information Mechanical installation Install the product according to the regulations of the corresponding ƒ documentation. In particular observe the section "Operating conditions" in the chapter "Technical data". Provide for a careful handling and avoid mechanical overload. During handling ƒ...
Page 9
Safety instructions General safety information Disposal Recycle metals and plastic materials. Ensure professional disposal of assembled ƒ PCBs. This device contains a battery. According to European legislation you are obliged to ƒ dispose of batteries separately via the take−back systems specified. EDSIPCx7 EN 4.1...
Product description Application as directed Lenze Industrial PCs (IPCs) are used as directed if they are exclusively used for the implementation of operator concepts or the presentation of information in common industrial and commercial areas. A different use, or one beyond these purposes, is not permissible.
"Industrial PC" system "Industrial PC" system The "Industrial PC" system by Lenze offers a broad platform for the creation of devices configured in a customised manner providing corresponding hardware components for the respective application case. For the corresponding hardware components like CPU, ROM, RAM, etc.
Page 12
Product description "Industrial PC" system Centralised and decentralised solutions Depending on the requirements with regard to the installation of the Industrial PC, both centralised Panel PC solutions and decentralised (separate) solutions can be selected. Centralised solutions:The Panel PCs of the "Embedded Line (EL)" and "Command Station (CS)"...
Page 13
IPCs and operator panels, which due to their complexity cannot always be implemented by means of standard components. In these cases Lenze is the solution partner for customised developments. Typical developments are: Customised decoration foil for a consistent Corporate Design ƒ...
In the Embedded Line and Command Station types apart from the Industrial PCs also Thin Clients (EL 1800 − 9800 TC, CS 5800 − 9800 TC) and monitor panels (MP 800 − 9000 DVI, CS 5000 − 9000 DVI) are available.
Monitor panel (MP): A monitor panel is an operator terminal to use remote Industrial PCs as a built−in variant or stand−alone terminal. Like the Embedded Line devices, they feature corresponding front modules. Type EL 1800 − 9800 EL 1800 − 9800 TC MP 800 − 9000 DVI Function Thin Client Monitor panel 20.3 cm (8"), 26.4 cm...
Product description Overview of designs Command Station 3.3.2 Command Station A Command Station (CS) is a stand−alone operator station which is protected against dust and splash water at each side. The flat housing features a mounting frame on the rear side, which can be mounted on a support arm or a wall.
Product description Overview of designs Cabinet PC 3.3.3 Cabinet PC The decentralised solutions comprise separate units, the Industrial PC which is preferably placed in a protected manner in the control cabinet, and the operating unit on site. This solution has advantages with regard to cabling, operating conditions, and accessibility. The following can be used as a screen: A standard monitor.
Panel PC EL EL 1800 / EL 1800s / EL 2800 / EL 5800 / EL 9800 Thin Client EL EL 1800 TC / EL 1800s TC / EL 2800 TC / EL 5800 TC / EL 9800 TC Monitor Panel MP 800 DVI / MP 1000 DVI / MP 1000s DVI / MP 2000 DVI / MP 5000 DVI / MP 9000 DVI EL 1800 (TC): VGA touchscreen 26.4 cm (10,4")
Page 19
Product description Embedded Line (EL, MP) design Panel PC EL 5820 Thin Client EL 5820 TC Monitor Panel MP 5020 DVI XGA touchscreen 38.1 cm (15") 12 freely assignable function keys 14 freely assignable special keys Power Fail Enter Status ELx7xx−002 Panel PC EL 1850 / EL 1850s / EL 2850 / EL 5850 Thin Client EL 1850 TC / EL 1850s TC / EL 2850 TC / EL 5850 TC...
Product description Command Station (CS) design Command Station (CS) design Elements PS/2 RS232 CF Card Power MC Card Fail Status Reset ACU UPS 24 V DC CS57x0−001 Pos. Description Command Station (IPC, here CS 5800) Command Station TC (Thin Client) Command Station DVI (monitor panel) Mounting frame with VESA−100 adapter surface PC or monitor control for the monitor panel...
Page 21
Product description Command Station (CS) design Command Station CS 5810 Command Station CS 5810 TC Command Station CS 5010 DVI XGA touchscreen 38.1 cm (15") 3 freely assignable function keys Up to 7 freely assignable switching elements (^ LEERER MERKER) Emergency−off switch Power Fail...
Page 22
Product description Command Station (CS) design Add−on components (accessories) Operator console CSB 7 Up to 7 freely assignable switching elements that can be used in any combination Emergency−off switch Internal cabling for Command Station with Combicon plug CS57x0−030 Operator console CSB 14 Up to 14 freely assignable switching elements that can be used in any combination Emergency−off switch...
Product description Cabinet PC (CPC) design 3241 C Cabinet PC (CPC) design 3.6.1 3241 C System overview EPM-S701 IPC 3241 C I/O System 1000 32xxC_005 Fig. 3−3 IPC 3241 C with connected I/O system 1000 (grey) For information on the I/O system 1000, please refer to the system manual "I/O system 1000".
Page 24
Product description Cabinet PC (CPC) design 3241 C Elements 32xxC−001 Pos. Description IPC 3241 C Locking lever (DIN rail) Backplane bus contacts Guide for DIN rail with thermal connection via GapPad strips Status LEDs Reset button Contact cover EDSIPCx7 EN 4.1...
Product description Cabinet PC (CPC) design CPC 2800 3.6.2 CPC 2800 Elements CPC2700−001 Pos. Description Control cabinet PC DVD drive (optional) PS/2 LAN (Ethernet) Status LEDs Error (red): Is lit if a power supply failure has occurred; HD (yellow): Indicates access to a storage medium. Power (green): Is lit when the supply voltage is present.
Product description Cabinet PC (CPC) design CPC 5100 3.6.3 CPC 5100 Elements KEYB MOUSE COM1 < STANDBY POWER AUDIO CTRL RESET > CPC5100−001 Pos. Description Control cabinet PC Mains connection 115 ... 230 V AC Mains switch From left to right: Keyboard connection (PS/2) Mouse connection (PS/2) From left to right:...
Product description Cabinet PC (CPC) design CPC 9100 3.6.4 CPC 9100 Elements > < CPC9100−001 Pos. Description Control cabinet PC Mains connection 115 ... 230 V AC Mains switch UPS control cable (only for power supply unit with integrated UPS) from bottom to top: Keyboard connection (PS/2) Mouse connection (PS/2)
Description The optional ACU UPS control unit in connection with a battery or capacitor pack adds a UPS functionality to the Industrial PC of the EL 1800−9800, CS 5800−9800, CPC 2800, and 3241 C series. The ACU UPS control unit is either pre−equipped by the factory or can be refitted by the Lenze Service staff.
For connection to a CAN fieldbus; IPC 3241 C the card features 2 independent IPC CPC 2800 CAN interfaces IPC CS 5800 − 9800 IPC EL 1800 − 9800 MC−ETC For connection to a EtherCAT IPC 3241 C network IPC CPC 2800 IPC CS 5800 −...
For further information please see the corresponding separate manuals. 3.9.2 Other software types Industrial PC Software Description EL 1800 − 9800 TC Thin Client connection Terminal Client Manager for configuring the manager connection to the server and the desired programs. CS 5800 − 9800 TC...
Fan monitoring with "Smart Cool" and "FAN Service" (option) 3.9.3 Fan monitoring with "Smart Cool" and "FAN Service" (option) The "Smart Cool" and "Fan service" softwares can be used for the following IPCs: EL 1800 − 9800 ƒ CS 5800 − 9800 ƒ...
Index Index 3241 C, 23 Embedded Line, 18 − design, 15 ACU UPS control unit, 28 − features, 14 Application as directed, 10 Fan monitoring, 31 Battery pack, 28 FAN Service, 31 Cabinet PC I/O system 1000, 23 − 3241 C, 23 Industrial PC system, 11 −...
Page 33
Index Validity, documentation, 4 EDSIPCx7 EN 4.1...