Lenze EL 1800 Operating Instructions Manual

L?force controls
Hide thumbs Also See for EL 1800:

Advertisement

BA_ELx8xx
.NnG
L−force Controls
Industrial PC
-
+
F1
F2
F3
F4
F5
F6
F7
F8
Q
W
E
R
T
Z
U
I
@
A
S
D
F
G
H
J
K
Y
X
C
V
B
N
M
;
,
μ
EL 1800 ... EL 9800
Embedded Line Panel PC (EL)
Operating Instructions
S1
S2
S3
Power
S4
Fail
Status
F1
S5
F2
+
F3
S6
-
S7
Power
Fail
Esc
Status
/
(
)
7
8
9
-
$
&
4
5
6
+
!
"
§
1
2
3
*
=
>
,
0
<
|
/
Power
Fail
Status
Bs
Einfg
Entf
Bild
Alt Gr
Pos 1
Ende
Bild
Alt
Strg
F9
F10
F11
F12
Esc
O
P
Ü
*
~
+
L
Ö
Ä
?
Enter
ß
\
_
Q
:
.
-
Space
F1
-
+
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
Enter
A
7
8
E
4
5
I
1
2
M
.
0
Home
Ins
Bs
Ctrl
Shift
Alpha
-
+
R
S
T
U
V
W
X
Y
Z
\
@
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
l
S8
S9
S10
S11
S12
S13
S14
B
C
D
-
9
F
G
H
6
+
J
K
L
3
*
N
O
P
,
/
Pg Up
Power
Fail
Status
End
Pg Dn
Del
Esc
Alt
Menu
Space
Enter

Advertisement

Table of Contents
loading

Summary of Contents for Lenze EL 1800

  • Page 1 Power Fail Status Home Einfg Entf Bild Pg Dn Alt Gr Pos 1 Ende Bild Strg Ctrl Menu Ü Shift Space € Ö Ä Enter ß Alpha Enter Space μ EL 1800 ... EL 9800 Embedded Line Panel PC (EL)
  • Page 2 Please read these instructions before you start working! Follow the enclosed safety instructions.
  • Page 3: Table Of Contents

    5.4.1 Panel PC EL 1800(s) / EL 1850(s) ....... . .
  • Page 4 ..........7.2.1 Panel PC EL 1800 / EL 1800s / EL 2800 / EL 5800 / EL 9800 ...
  • Page 5: About This Documentation

    Qualified skilled personnel are persons who have the required qualifications to carry out all activities involved in installing, mounting, commissioning, and operating the product. Tip! Information and auxiliary devices related to the Lenze products can be found in the download area at http://www.Lenze.com...
  • Page 6: Document History

    About this documentation Document history Document history Material number Version Description .NnG 02/2014 TD06 New: UL notes (French language) Notes RJ45 cable laying 13433080 03/2013 TD29 General revision 13391236 10/2011 TD29 Supplement of the note concerning the protection against direct solar radiation, as well as revision of the sections ˆReplacing the battery˜...
  • Page 7: Conventions Used

    About this documentation Conventions used Conventions used This documentation uses the following conventions to distinguish between different types of information: Type of information Identification Examples/notes Spelling of numbers Decimal separator Point In general, the decimal point is used. For instance: 1234.56 Warnings UL warnings Given in English and French...
  • Page 8: Notes Used

    About this documentation Notes used Notes used The following pictographs and signal words are used in this documentation to indicate dangers and important information: Safety instructions Structure of safety instructions: Danger! (characterises the type and severity of danger) Note (describes the danger and gives information about how to prevent dangerous situations) Pictograph and signal word Meaning...
  • Page 9: Safety Instructions

    The manufacturer does not accept any liability for the suitability of the specified procedures and circuit proposals. Only qualified skilled personnel are permitted to work with or on Lenze drive and ƒ...
  • Page 10 Safety instructions General safety information Transport, storage Transport and storage in a dry, low−vibration environment without aggressive ƒ atmosphere; preferably in the packaging provided by the manufacturer. – Protect against dust and shocks. – Comply with climatic conditions according to the technical data. Mechanical installation Install the product according to the regulations of the corresponding ƒ...
  • Page 11 Safety instructions General safety information Maintenance and servicing The components are maintenance−free if the required operating conditions are ƒ observed. If the cooling air is polluted, the cooling surfaces may be contaminated or the air ƒ vents may be blocked. Under these operating conditions, the cooling surfaces and air vents must be cleaned at regular intervals.
  • Page 12: Product−Specific Safety Instructions

    Safety instructions Product−specific safety instructions Product−specific safety instructions Protect the device against direct solar radiation, since the housing may heat up ƒ strongly. The device is classified as a class A device and can cause radio interference in ƒ residential areas. In this case, the operator may have to take special measures. Any costs arising from these measures have to be paid by the operator.
  • Page 13: Safety Instructions For The Installation According To Ul

    Safety instructions Safety instructions for the installation according to UL Safety instructions for the installation according to UL Original − English Approval Underwriter Laboratories (UL), UL508 and CSA C22.2 No. 142−M1987, (UL File Number E236341) Ratings Input 24 V DC, 65 W ƒ...
  • Page 14 Safety instructions Safety instructions for the installation according to UL Original − French Homologation Underwriter Laboratories (UL), UL508 et CSA C22.2 n° 142−M1987, (n° de dossier UL E236341) Caractéristiques assignées Entrée 24 V CC, 65 W ƒ Température ambiante maximale : 40 °C ƒ...
  • Page 15: Product Description

    Product description Scope of supply Quanti Name Embedded Line Panel PC Screw clamp fixings EL 1800, EL 1800s, EL 1850, EL 1850s EL 2800 EL 2850, EL 5800, EL 5820, EL 5850 EL 5870 EL 9800 Connection plug for voltage supply DVD "PC based Automation"...
  • Page 16: Application As Directed

    Product description Application as directed Application as directed The industrial PC is used as directed if it is solely used for implementing control and operating concepts or for presenting information in usual industrial and commercial fields. A different use, or one beyond these purposes, is not permissible. A use that is not intended also includes a use harbouring fatal risks or dangers which, without the provision of exceptionally high safety measures, may result in death, injury or damage to material assets.
  • Page 17: Device Features

    Product description Device features Device features EL x8xx Design PC housing made of sheet steel, in the case of passive cooling partly of aluminium Front frame made of anodised and etched aluminium Front with polyester foil Mounting For installation in control cabinets, control boards or machine enclosures Electrical supply 24 V DC voltage supply Lithium battery for buffering the real time clock (RTC)
  • Page 18 Panel PC EL 1800 / EL 1800s / EL 2800 / EL 5800 / EL 9800 Thin Client EL 1800 TC / EL 1800s TC / EL 2800 TC / EL 5800 TC / EL 9800 TC EL 1800 (TC): VGA touchscreen 26.4 cm (10.4") EL 1800s (TC): SVGA touchscreen 26.4 cm (10.4")
  • Page 19 Product description Device features Panel PC EL 5870 Thin Client EL 5870 TC XGA touchscreen 38.1 cm (15") 12 freely assignable function keys MF2 keyboard & " § > < Power Fail Status Einfg Entf Bild Alt Gr Pos 1 Ende Bild Strg...
  • Page 20: Identification

    Product description Identification Identification 31855 Aerzen; Germany † Made in Germany  ‚ Type ƒ ‡ „ 107AT12345 … ˆ 107AT12345 DVIUSB−012  Type designation ‚ Type code (catalogue/order no.) ƒ Technical data „ Customised material number … Bar code with serial number †...
  • Page 21 Product description Identification ‚ Type code EL x8xx EP8GAP 00− MC card slot 1 0 = without 9 = MC−CAN2 B = MC−CAN2 (with Light API licence) 1 = MC−ETH D = MC−ISI C = MC−MPI 5 = MC−PBM 6 = MC−PBS 8 = MC−PND MC card slot 2 0 = without...
  • Page 22 Product description Identification ‚ Type code EL x8xx EP8GAP 00− Number of power tags for visualisation 0 = without 1 = 50 power tags 2 = 100 power tags 3 = 250 power tags 4 = 500 power tags 5 = 1000 power tags 6 = 2000 power tags 7 = 4000 power tags 8 = 64000 power tags...
  • Page 23: Controls And Displays

    Product description Controls and displays Controls and displays PS/2 RS232 CF Card MC Card Reset ACU UPS 24 V DC Power Fail Status ELx7xx−001 Pos. Description Panel PC / Thin Client (here Panel PC EL 5800) Front face USB port (option) Screw clamp fixings DVD drive (optional) Nameplate...
  • Page 24: Options

    Description The optional ACU UPS control unit in connection with a battery or capacitor pack adds a UPS functionality to the Industrial PC of the EL 1800−9800, CS 5800−9800, CPC 2800, and 3241 C series. The ACU UPS control unit is either pre−equipped by the factory or can be refitted by the Lenze Service staff.
  • Page 25: Baseboard

    Product description Baseboard Baseboard FLAT-PANEL-LVDS FAN0 POWER FAN3 FAN2 CR2450 FAN1 COM1 ACCU RESET POWER CF-CARD x8xx_001 Hard disk CPU module Battery ( ^ 52) ACU UPS control unit ( ^ 24) Fuse ( ^ 53) Socket connector for MC card BA_ELx8xx EN 3.0...
  • Page 26: Technical Data

    Technical data General data and operating conditions Technical data General data and operating conditions General data Conformity and approval Conformity EN 61000−6−4 EMC Directive Class A, industrial premises EN 61000−6−2 Approbation UL 508 Programmable Controllers (File−No. E236341) CSA C22.2 Other RoHS −...
  • Page 27: Operating Conditions

    Technical data General data and operating conditions Operating conditions Mounting conditions Place of installation In the control cabinet, screen protected against direct solar radiation Mounting position Connections at the bottom Ambient conditions Climatic Storage −10 ... +60 °C Transport −10 ... +60 °C Operation Depending on the equipment (^ 28) Relative humidity...
  • Page 28 Technical data General data and operating conditions Note! The failure probability of an electronic component increases with the ambient temperature to which the component is subjected. Regarding the serviceability and reliability, particular attention should be paid to the cooling of the device. For every application, you should take care to keep the heating of the device as low as possible.
  • Page 29: Electrical Data

    â â Intel Core Duoä Intel Atomä Type Type Service life [DC V] [years] EL 1800 EL 1800s EL 1850 EL 1850s EL 2800 ^ 53 ^ 52 EL 2850 24 (+18 ... 30) > 6 (25 °C) EL 5800...
  • Page 30: Mechanical Data

    Technical data Mechanical data Mechanical data Versions and weights Front frame / housing Touchscreen Mass [kg] EL 1800 EL 1800s EL 1850 EL 1850s EL 2800 EL 2850 Aluminium/sheet steel Polyester foil EL 5800 EL 5820 EL 5850 EL 5870 EL 9800 10.6...
  • Page 31 Technical data Mechanical data CD/DVD 27.5 CD/DVD ELx7xx−003 All dimensions in millimetres. Dimensions [mm] EL 1800 EL 1800s EL 1850 EL 1850s EL 2800 EL 2850 EL 5800 EL 5820 310 (7 U) EL 5850 EL 5870 399 (9 U) EL 9800 BA_ELx8xx EN 3.0...
  • Page 32: Mechanical Installation

    Mechanical installation Important notes Mechanical installation Important notes The installation must be carried out by qualified, skilled personnel familiar with the applicable national standards. Stop! Sensitive front frame gasket During mounting, the gasket of the front frame is exposed and can be damaged.
  • Page 33: Mounting Cutout

    Mechanical installation Mounting cutout Mounting cutout £ 5 ELx7xx−004 Mounting cutout Outline of front panel Control board All dimensions in millimetres. Dimensions [mm] EL 1800 305.0 − 228.0 − − − − − EL 1800s EL 1850 343.0 − 228.0 −...
  • Page 34: Mounting Steps

    Mechanical installation Mounting steps Panel PC EL 1800(s) / EL 1850(s) Mounting steps 5.3.1 Panel PC EL 1800(s) / EL 1850(s) How to perform the installation: 1. Cut the mounting cutout into the control board (¶ 33). 2. Check that the gasket under the front panel is located correctly.
  • Page 35: Panel Pc El 2800 / El 2850 / El 5800 / El 5820 / El 5850 / El 5870 / El

    Mechanical installation Mounting steps Panel PC EL 2800 / EL 2850 / EL 5800 / EL 5820 / EL 5850 / EL 5870 / EL 9800 5.3.2 Panel PC EL 2800 / EL 2850 / EL 5800 / EL 5820 / EL 5850 / EL 5870 / EL 9800 Note! Types EL 5820, EL 5850, and EL 5870 can be installed in any control panel and in 19"...
  • Page 36: Electrical Installation

    Electrical installation Important notes Electrical installation Important notes The installation must be carried out by qualified, skilled personnel familiar with the applicable national standards. Stop! Short circuit and static discharge The device contains components which are endangered in the case of short circuit or static discharge.
  • Page 37: Wiring According To Emc

    Electrical installation Wiring according to EMC Wiring according to EMC General notes The electromagnetic compatibility of the system depends on the type and accuracy of the installation. Please especially note the following: – Structure – Shielding – Earthing In the case of a differing installation it is required for evaluating the conformity to the EMC Directive to check the system with regard to compliance with the EMC limit values.
  • Page 38: Connecting The Supply And Peripheral Devices

    Electrical installation Connecting the supply and peripheral devices Terminal diagram supply Connecting the supply and peripheral devices 6.3.1 Terminal diagram supply L1 N PE +24 V Elx7xx−006 Power supply unit Battery pack (Option) Capacitor pack (Option) Note! Observe the max. permissible input voltage. ƒ...
  • Page 39: Ups−Pack Connection (X102)

    Electrical installation Connecting the supply and peripheral devices UPS−PACK connection (X102) 6.3.3 UPS−PACK connection (X102) Description Connection type Cable type In the scope of supply of the Terminal for Battery pack / 2−pin socket pack; length 2.5 m; extension Capacitor pack available IPC001 6.3.4...
  • Page 40: Usb Interface (X104, X105, X106)

    Electrical installation Connecting the supply and peripheral devices USB interface (X104, X105, X106) 6.3.7 USB interface (X104, X105, X106) Description Connection type Cable type USB 2.0 host connection USB−A socket USB cable with USB−A plug Max. load: 5 V/500 mA IPC001 6.3.8 Communication interface (MC card)
  • Page 41: Operation

    Operation Important notes Operation Important notes Stop! Sensitive touchscreen surface The touchscreen foil is very sensitive to external forces and can be damaged by improper handling. Possible consequences: The touchscreen foil becomes damaged, scratched or dull. ƒ Protective measures: Avoid contact of the touchscreen foil with pointed or hard objects. ƒ...
  • Page 42: Controls And Displays

    Operation Controls and displays Panel PC EL 1800 / EL 1800s / EL 2800 / EL 5800 / EL 9800 Controls and displays 7.2.1 Panel PC EL 1800 / EL 1800s / EL 2800 / EL 5800 / EL 9800...
  • Page 43: Panel Pc El 5820

    Operation Controls and displays Panel PC EL 5820 7.2.2 Panel PC EL 5820 Power Fail Enter Status ELx7xx010 Pos. Designation Function Standard mode Service mode Switch on mode: Press "[" for 4 s Switch off mode: Press "[" or wait for 35 s Display Application−dependent Status LEDs...
  • Page 44: Panel Pc El 1850 / El 1850S / El 2850 / El 5850

    Operation Controls and displays Panel PC EL 1850 / EL 1850s / EL 2850 / EL 5850 7.2.3 Panel PC EL 1850 / EL 1850s / EL 2850 / EL 5850 Pg Up Power Fail Status Home Pg Dn Ctrl Menu Shift Space...
  • Page 45 Operation Controls and displays Panel PC EL 1850 / EL 1850s / EL 2850 / EL 5850 Pos. Designation Function Standard mode Alpha mode Service mode Switch on mode: Press "alpha key" (LED is on) Press "menu key" Switch off mode: Press "alpha key"...
  • Page 46: Panel Pc El 5870

    Operation Controls and displays Panel PC EL 5870 7.2.4 Panel PC EL 5870 & " § > < Power Fail Status Einfg Entf Bild Alt Gr Pos 1 Ende Bild Strg Ü € Ö Ä Enter ß Space μ ELx7xx009 Pos.
  • Page 47: Maintenance

    Maintenance Regular checks Maintenance Stop! Short circuit and static discharge The device contains components which are endangered in the case of short circuit or static discharge. Possible consequences: The device or parts of it will be destroyed. ƒ Protective measures: Always switch off the voltage supply when working on the device.
  • Page 48: Cleaning

    Maintenance Cleaning Cleaning Stop! Sensitive surfaces and components The device can be damaged if it is not appropriately cleaned. Possible consequences: The housing or the screen gets scratched or dull if you use alcoholic, ƒ solvent−containing or scouring cleaning agents. Electrical components can be damaged ...
  • Page 49: Repair

    Maintenance Repair Remove the PC housing Repair 8.3.1 Remove the PC housing With DVD drive  ‚ ƒ „ ELx7xx−013 Proceed as follows when a DVD drive is mounted: 1. Remove the 24 V cable 0 (¶ 38) 2. Remove the DVD drive 1: –...
  • Page 50 Maintenance Repair Remove the PC housing Without DVD drive ƒ  ‚ ELx7xx−015 Proceed as follows when no DVD drive is mounted: 1. Remove the 24 V cable 0 (¶ 38). 2. Only for fanless devices: Loosen the three screws 1. 3.
  • Page 51: Mount The Pc Housing

    Maintenance Repair Mount the PC housing 8.3.2 Mount the PC housing With DVD drive  ‚ ƒ „ ELx7xx−014 Proceed as follows when a DVD drive is mounted: 1. Mount the housing 0: – Pass the ribbon cable 1 through the housing aperture and carefully place the housing 0 on the housing base.
  • Page 52: Battery Change

    Maintenance Repair Battery change Without DVD drive  ‚ ƒ ELx7xx−016 Proceed as follows when no DVD drive is mounted: 1. Mount the housing 0: – Carefully place the housing 0 on the housing base. – Screw in the four screws 1. 2.
  • Page 53: Fuse Change

    Maintenance Repair Fuse change FAN3 FAN2 CR2450 ACCU RESET CF-CARD POWER ELx7xx−017 How to proceed: 1. Remove the MC Card, if inserted. 2. Remove the old battery 0 from the support. 3. Insert a new approved battery 0 into the support so that the positive pole is at the top.
  • Page 54 Maintenance Repair Fuse change FAN3 FAN2 CR2450 ACCU RESET CF-CARD POWER ELx7xx−018 How to proceed: 1. Remove the MC Card, if inserted. 2. Remove the old fuse 0 from the support. 3. Insert a new approved fuse 0 into the support. BA_ELx8xx EN 3.0...
  • Page 55: Index

    Baseboard, 25 Display, 29 Fuse, change, 53 Battery, change, 52 Display elements Battery pack, 24 − EL 1800(s), 42 − EL 1850(s), 44 General data, 26 − EL 2800, 42 − EL 2850, 44 Capacitor pack, 24 − EL 5820, 43...
  • Page 56 Index Maintenance, 47 Operation, 41 Supply, 29 − Back−up battery, 52 Overview, 23 − Cleaning, 48 − Fuse, 53 Technical data, 26 − Mount the PC housing, 51 − Electrical data, 29 PC housing − Regular checks, 47 − General data, 26 −...
  • Page 57 © 02/2014 Lenze Automation GmbH Service Lenze Service GmbH Postfach 10 13 52, D−31763 Hameln Breslauer Straße 3, D−32699 Extertal Hans−Lenze−Str. 1, D−31855 Aerzen Germany Germany +49 5154 82−0 008000 2446877 (24 h helpline) Ê Ê +49 5154 82−2800 +49 5154 82−1112 š...

This manual is also suitable for:

El 9800

Table of Contents