Install Water Leak Sensor And Water Detector; Supplied Components; Mounting Location Guidelines - OneVue Sense E121 Installation Manual

Water leak sensor
Table of Contents

Advertisement

Install Water Leak Sensor and Water Detector

Supplied components

Inspect the package contents to verify the supplied components are present and no damage has occurred during
shipping.
Quantity
Component
1
Water Leak Sensor
1
Water Detector
1
AC power adapter: 5V DC USB Mini B (5 pin) connector interface, 5 ft (1.5 m) cable, Input: 100-240 VAC, 50/60 Hz, 0.4A, Output: 5V DC,
1.0A max
1
Primex 3.0v Lithium/Iron Disulfide Battery Pack (contains 2 AA 1.5V Energizer® Ultimate Lithium batteries)
2
3M™ Dual Lock Fastener & Tape, 2" x 1" strips
1
USB configuration cable; supplied with a device order only. For use with the Primex Device Configuration software to manually configure a
device or troubleshoot device network connectivity issues. It's recommended to save this cable for future use.

Mounting location guidelines

The location of the sensor and detector impacts its use and operation. Be sure to identify a location that meets the
following guidelines. For mounting illustrations, see topic Water Leak Sensor application uses [4].
Water Leak Sensor location
• Sensor is not water-resistant or waterproof. Mount at a minimum of 3 ft. (0.91 m) above floor level; avoid exposing
device to water.
• Easily accessible for maintenance and clear from obstructions. Avoid a location that would interfere with the use of
the monitored unit or area.
• Wireless Network use
It's recommended that the device is in a clear line of sight to a wireless access point. If the location is NOT in a clear
line of sight to a wireless access point, its LCD screen must be above the unit it's being mounted to.
Wireless signal strength of -60db or better at the mounting location. It's recommended to measure the strength with
a Wi-Fi analyzer app on a mobile phone.
• PoE/Ethernet use
An open, active network port in close proximity to the mounting location.
• AC power
Outlet within 5 ft. (1.5 m) from its mounting location. Devices using AC or PoE power can also use battery power as a
backup power source in the event of a power loss. During battery backup, the device operates on battery power and
continues to log and transmit readings until the primary power source is restored.