Step 1: Verify Sensor Configuration - OneVue Sense E121 Installation Manual

Water leak sensor
Table of Contents

Advertisement

CAUTION
The device is shock and vibration resistant; however, be careful not to drop or install the device in a
location where it could be exposed to excessive vibration.
Water Detector placement
A Water Detector can be placed directly on a floor surface for low-water level detection or above the floor for higher
water-level detection.
• Ensure placement surface is smooth and clean.
If the unit's metal contacts come into contact with a foreign material (oil, detergent, etc.), then contacts may repel
water and therefore will not be able to properly detect water.
• Locate in an area that does not allow the cable to be excessively pulled, bent, or placed under heavy objects.
To secure cable, standard plastic U-clip or half U-clip with an adhesive base can be used.
• Low-level water detection
Water Detector must be placed on the floor with the logo facing the ceiling and the bottom side two metal contacts
facing down on the surface.
• High-level water detection
Water Detector must be placed vertically with the logo facing you and the bottom two metal contacts facing down
towards the area being monitored.
Connecting multiple Water Detectors
For larger areas, it's recommended to daisy chain up to four Water Detectors along the entire perimeter of the floor or in
the area where the assets being monitored are located. Each Water Detector has an input that allows for connecting
multiple water detectors in a series to monitor larger areas.
• A single Water Leak Sensor allows up to four connected Water Detectors.
• To prevent damage to the Water Detector components the input plug should remain in place while not in use.

Step 1: Verify sensor configuration

Prior to installation, a sensor device must be configured for use with OneVue. A sensor is either configured prior to
shipment through Device Preconfiguration or onsite using the OWDC app.
• Device Preconfiguration completed: white label with configured settings is affixed to the backside of the sensor.
Sensor has been configured with network settings allowing its connection to OneVue and also added to OneVue.
Proceed to next install step.
• OWDC onsite configuration required: Sensor shipped with factory default settings and is not added to OneVue.
You must configure the sensor now using the OWDC app.