Manual Pam Configuration; Panel Api Communication Options - HID PIVCLASS M2000 Installation And Configuration Manual

Table of Contents

Advertisement

PLT-01628, Rev. D.2

5.4 Manual PAM configuration

This section describes how to setup the PACS Service to PAM communication path and manually add a PAM
within Reader Services.

5.4.1 Panel API communication options

Before you begin manual PAM configuration check the panel API communication options in the PACS Service
application:
1. Start the PACS Service application and select Configuration > Edit Service Settings.
2. Select Reader Services tab and ensure the Enable PAM 5 API option is selected.
Note: If the default port number 10200, is not accepted, enter a new port number in the
Port number field. Record the port number and retain it for later use to configure the PAM.
3. It is recommended that the Enable TLS encryption and Enable TLS client mutual authentication
options are selected to encrypt communication the PACS Service and API client.
For additional information on PACS Service encrypted communication and TLS parameter options,
select F1 while on the Reader Services tab to access the relevant PACS Service Online Help topic.
January 2019
PAM configuration
23

Advertisement

Table of Contents
loading