Figure 9
Note: Cover removal for certain larger models with a Terminal Cover:
-Single-Phase 200 V Class: CIMR-V BA0006 to BA0018
-Three-Phase 200 V Class: CIMR-V 2A0008 to 2A0069
-Three-Phase 400 V Class: All models
Remove the terminal cover before removing the bottom cover to install the PROFIBUS-DP Option. Replace the terminal cover
after wiring the PROFIBUS-DP Option.
Figure 10
4. Reattach the bottom cover.
5. Connect the PROFIBUS-DP Option to the drive. Properly secure the tabs on the left and right sides of the PROFIBUS-
DP Option to the drive case.
Figure 11
6. Connect the ground cable from the drive ground terminal to the PROFIBUS-DP Option ground. When wiring the
PROFIBUS-DP Option, pass the ground cable through the inside of the drive bottom cover, then pass the ground cable
into the through-hole at the front of the PROFIBUS-DP Option.
Figure 12
YASKAWA ELECTRIC SIEP C730600 23B V1000 Option PROFIBUS-DP Technical Manual
A
A – Option unit connection: screw size = M3
B – Drive-side connection: screw size = M3.5 to M6
Figure 10 Ground Cable
Figure 11 Models with Terminal Cover
Tabs should line up
Figure 12 Attach PROFIBUS-DP Option
Ground cable
Through-hole
Ground
for ground cable
cable
Figure 13 Ground Cable Connection
B
Tabs should line up
Drive ground
terminal
Pass the ground
cable through
the bottom cover
of the drive.