11.0 - DELETING PROGRAMMED DEVICES

To carry out the operation successfully, make sure the required electrical connections
(bonnet switch and ignition) are properly connected.
!
If there is no bonnet switch, ground the GREEN wire (20-pin connector, pos. 15).
All devices previously programmed can be deleted. To clear memory proceed as follows:
• With the system disarmed, open the vehicle bonnet and keep it opened or ground the GREEN wire.
The "ON-OFF" cycles must be carried out within 4 sec. otherwise the procedure is
!
• Cycle ignition key
"
ON-OFF
" "
-
ON-OFF
• At the 4th cycle, leave ignition key "ON".
• A siren chirp and
2 flashes of the turn indicators
will turn ON steady.
• Close the bonnet or remove the GREEN wire from ground (bonnet switch).
• Leave the bonnet closed for at least 8 seconds to clear the memory.
If the bonnet is opened before 8 seconds, the devices will not be
!
• The LED will switch OFF when the devices have been deleted.
• Turn ignition key "OFF".
• A flash of the turn indicators will confirm the end of the clearing procedure.

12.0 - SYSTEM RESET

By activating the following procedure, the system returns to the
!
This procedure must therefore only be used in case of need, before programming the
system or auto-learning the turn indicator flashes.
To reset the system proceed as follows:
• Disconnect the system.
• Short-circuit the RED and BLACK wires of the 2-pin LED connector.
• Connect the system; once the alarm system is powered, 4 acoustic signals will sound and the turn
indicators will flash 4 times.
• Remove the previously created short-circuit; the status LED will light up steady.
• Turn ignition key "ON"; reset is confirmed by the wailing of the siren for approx. 3 seconds.
• Turn ignition key "OFF". The LED turns OFF and there are no acoustic signals.
PAGE 12
invalidated.
" "
-
ON-OFF
" "
-
ON
"
.
will confirm the system is in delete mode.The LED
deleted.
factory default
932MHW UNIT :
Current draw (system armed + LED flashing)
Turn indicators relay contact capacity
Engine immobilizer relay contact capacity
Maximum positive current output when armed (+A)
SIREN 725W:

14.0 - WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT DIRECTIVE (WEEE)

The present device does not fall within the scope of Directive 2002/96EC on Waste Electrical and
Electronic Equipment (WEEE) as specified in art. 2.1 of L. D. No. 151 of 25/07/2005.
state.

13.0 - TECHNICAL SPECIFICATIONS

Power supply
Operating temperature range
Alarm cycle duration
Power supply
Operating temperature range
Current draw (when triggered)
Current draw (in standby)
Maximum siren output
12Vdc
15mA
@ 12Vdc
-30°C => +70°C
8A @ 20°C
8A @ 20°C
30 sec.
700mA
10 - 15 Vdc
-35°C => +80°C
1.5A @12Vdc
2.5mA @12Vdc
108dB @ 1m
PAGE 13