Status Displays - Siemens SIMOTION P320-3 Manual

With panel fronts
Table of Contents

Advertisement

3.2.4

Status displays

Status indicator
Status indicator
LED
Meaning
PWR
Power supply
WD
Watchdog status
display
SF
Group errors
RUN/STOP
RUN
STOP
SF PROFINET
Status indicator for
PROFINET onboard
SIMOTION P320-3 and Panel Fronts
Manual, 02/2012
LED
GREEN
OFF
OFF
RED: Slow flashing
(0.5 Hz)
RED: Fast flashing (2 Hz)
RED
OFF
YELLOW
GREEN
OFF
RED: Slow flashing
(0.5 Hz)
RED: Fast flashing (2 Hz)
RED
3.2 SIMOTION P320-3 PC unit
Description
Indicates correct supply voltage of 3.3 V, 5 V and 12
V from the integrated power unit.
Not relevant.
SIMOTION P is operating without error.
No license exists for technology/optional objects
under license. Carry out the licensing to correct the
error.
Further information on the licensing can be found in
the SIMOTION P320-3 and Panel Fronts
Commissioning and Hardware Installation Manual.
A fault has occurred to which the user program
cannot respond.
The following actions may be required to rectify the
fault:
Power OFF/ON
New commissioning procedure
An interrupt which can be acknowledged is present
(alarm, message, note).
(See Diagnostics Guide)
SIMOTION P Runtime is not running
SIMOTION P in STOP mode
SIMOTION P in RUN mode
SIMOTION P is operating without error.
Underlicensing
No or faulty configuration.
Acknowledgeable event
Hardware description