Siemens SIMOTION P320-3 Manual page 109

With panel fronts
Table of Contents

Advertisement

Status displays on the device
PWR
GREEN
WD
OFF
SF (Group fault)
OFF
RED: Slow flashing (0.5 Hz)
RED: Fast flashing (2 Hz)
RED
RUN/STOP
OFF
YELLOW
GREEN
SF PROFINET
OFF
RED: Slow flashing (0.5 Hz)
RED: Fast flashing (2 Hz)
RED
SIMOTION P320-3 and Panel Fronts
Manual, 02/2012
Indicates correct supply voltage of 3.3 V, 5 V and 12 V from the
integrated power unit
Not relevant.
SIMOTION P is operating without error.
No license exists for technology/optional objects under license.
Carry out the licensing to correct the error.
Further information on the licensing can be found in the
SIMOTION P320-3 and Panel Fronts Commissioning and
Hardware Installation Manual.
A fault has occurred to which the user program cannot respond.
The following actions may be required to rectify the fault:
Power OFF/ON
New commissioning procedure
An interrupt which can be acknowledged is present (alarm,
message, note).
(See Diagnostics Guide)
SIMOTION P Runtime is not running
SIMOTION P in STOP mode
SIMOTION P in RUN mode
SIMOTION P is operating without error.
Underlicensing
No or faulty configuration
Acknowledgeable event
Technical data
9.1 General specifications
109