Siemens SIMOTION P320-3 Manual

With panel fronts
Table of Contents

Advertisement

Quick Links

SIMOTION P320-3 and Panel Fronts
SIMOTION
SIMOTION P320-3 and Panel
Fronts
Manual
02/2012
___________________
Preface
___________________
Safety notes
___________________
Description
___________________
Hardware description
___________________
Application planning
___________________
Installing/Mounting
___________________
Connecting
___________________
Service and maintenance
___________________
Troubleshooting/FAQs
___________________
Technical data
___________________
Dimension drawings
___________________
Spare parts/Accessories
___________________
Standards and approvals
___________________
ESD guidelines
___________________
List of abbreviations
1
2
3
4
5
6
7
8
9
10
11
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMOTION P320-3

  • Page 1 ___________________ SIMOTION P320-3 and Panel Fronts Preface ___________________ Safety notes ___________________ Description SIMOTION ___________________ Hardware description ___________________ SIMOTION P320-3 and Panel Application planning Fronts ___________________ Installing/Mounting Manual ___________________ Connecting ___________________ Service and maintenance ___________________ Troubleshooting/FAQs ___________________ Technical data ___________________ Dimension drawings...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Preface Contents of the Product Manual This manual describes the embedded IPC for motion control SIMOTION P320-3 and the SIMOTION P panel fronts that can be connected via the Remote Panel PC Kit. The manual is part of the SIMOTION P320-3 documentation package.
  • Page 4 ● Index to locate information Scope of validity This manual is valid for the hardware of the SIMOTION P320-3 and the SIMOTION panel fronts as of SIMOTION software version V4.1.5. The type designation of your SIMOTION P is shown on the type plate.
  • Page 5 Preface Conventions The term "PC" or "device" is used to refer to the SIMOTION P320-3 in this document. Standards The SIMOTION system was developed in accordance with ISO 9001 quality guidelines. SIMOTION Documentation An overview of the SIMOTION documentation can be found in a separate list of references.
  • Page 6 Preface My Documentation Manager Click the following link for information on how to compile documentation individually on the basis of Siemens content and how to adapt this for the purpose of your own machine documentation: http://www.siemens.com/mdm Training Click the following link for information on SITRAIN - Siemens training courses for automation products, systems and solutions: http://www.siemens.com/sitrain...
  • Page 7: Table Of Contents

    HMI or ES via PROFINET......................28 SIMOTION panel fronts .......................29 2.4.1 Overview of SIMOTION panel fronts ...................29 2.4.2 SIMOTION P320-3 with panel front via Panel PC Remote Kit ............30 2.4.3 SIMOTION P320-3 without panel front (headless) ..............31 Hardware description..........................33 SIMOTION P hardware components ...................33 SIMOTION P320-3 PC unit......................35...
  • Page 8 Mounting the SIMOTION panel front ..................88 5.5.1 Overview of the mounting of SIMOTION panel fronts ..............88 5.5.2 Securing the panel front with clamps ..................88 5.5.3 Securing the panel front with screws ..................90 SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 9 Over of power supply .........................127 11.1.2 Example: SITOP smart 24 V/10 A .....................128 11.1.3 Technical data for the SITOP smart 24 V/10 A................128 11.2 UPS system ..........................130 11.2.1 UPS system overview ........................130 11.2.2 SITOP DC UPS module......................131 SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 10 Certificates ..........................139 ESD guidelines ............................141 ESD definition ........................... 141 Electrostatic charging of individuals..................142 Basic measures for protection against discharge of static electricity ........143 List of abbreviations..........................145 Index..............................147 SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 11: Safety Notes

    Contact your technical support team or where you purchased your PC to find out which system expansion devices may safely be installed. CAUTION If you install or exchange system expansions and damage your device, the warranty becomes void. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 12 ● Always pull the mains connector and disconnect the battery before installing or removing modules which are sensitive to ESD. ● Handle modules fitted with ESDs only by their edges. ● Do not touch any connector pins or conductors on modules containing ESDs. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 13: Recycling And Disposal

    The low-pollution equipment used in the products described in this manual means most of them can be recycled. To recycle and dispose your old device in an environmentally friendly way, please contact a company that specializes in the disposal of electronic waste. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 14 Safety notes 1.2 Recycling and disposal SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 15: Description

    2.1.1 Product description Technical Description The PC-based SIMOTION P320-3 motion control system runs with the Windows Embedded Standard 2009 operating system and with a real-time expansion for SIMOTION. The hardware consists of an industrial PC with innovative Intel technology. Other PC applications can run at the same time as the SIMOTION applications. The I/O systems are controlled with the PROFINET onboard controller (= permanently integrated PROFINET onboard interface module) for PROFINET.
  • Page 16: Performance Features

    SIMOTION SCOUT engineering system (ES). This can be done using text or graphic input. User data is stored on a fail-safe storage medium of the SIMOTION P320-3. The term "storage medium" is used for "fail-safe storage medium" in the rest of the document.
  • Page 17 Five LEDs to display the system states Transient voltage interruption Up to 15 ms buffer time at full load Software Operating systems Scope of delivery Windows Embedded Standard 2009  SIMATIC NET  SIMOTION P Runtime  SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 18 Not available Windows .NET Messenger Available, V 4.7 Codepages/User Locale/Keyboard Selection available Disk Management Services Available Windows Installer Service Available, V 3.1 Class Installer Available CoDevice Installer Available Windows Movie Maker Not available SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 19: System Overview

    The truly innovative aspect of SIMOTION is that it does away with the traditional separation between pure automation functions and motion functions. These functions are combined both on the hardware and on the software side. Figure 2-1 SIMOTION system environment SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 20 SCOUT engineering system and the associated runtime software modules can be used on the various SIMOTION hardware platforms. The advantage of the system architecture for the PC-based SIMOTION P320-3 solution lies in the fact that both the HMI and the runtime system run on the same hardware. This saves the cost for an additional HMI station.
  • Page 21: Simotion P Structure

    SIMOTION P structure 2.2.1 SIMOTION P (hardware) structure The following figure illustrates the integration of the SIMOTION P320-3 with the use of the PROFINET onboard controller in a target system. Figure 2-2 Hardware system overview - example with PROFINET onboard controller...
  • Page 22: Simotion P (Software) Structure

    The SIMOTION SCOUT engineering system is linked via the interfaces integrated in the SIMOTION P320-3. HMI software HMI software can be installed on the same PC, e.g. the Siemens WinCC flexible software. Other software packages can be linked by means of the OPC interface. The following sections discuss only HMI software.
  • Page 23 Figure 2-3 Local communication Scope of delivery The system software supplied with the SIMOTION P is either already installed on the SIMOTION P320-3 storage medium or is ready to be installed: ● SIMOTION Kernel ● SIMATIC NET ● UPDD Touch Driver ●...
  • Page 24: Components

    For a detailed and routinely updated list of I/O modules enabled with SIMOTION as well as application information, visit us online at: Siemens - Industry Automation and Drive Technologies - Service & Support (http://support.automation.siemens.com/WW/view/en/11886029) Further modules are integrated via the GSD file of the device's manufacturer.
  • Page 25 Enables the physical separation of the SIMOTION panel front and SIMOTION P320-3 Operator components Operator components and the programming device (PG/PC) can be connected as follows: ● Local communication via PC-internal ● PROFINET ● Ethernet SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 26: Hmi And Simotion Scout

    2.3 HMI and SIMOTION SCOUT HMI and SIMOTION SCOUT 2.3.1 HMI overview The monitoring of the operational sequences on the SIMOTION P320-3 is generally performed via the HMI system (Human Machine Interface). The HMI software can be connected using the following methods: ● Local ●...
  • Page 27: Hmi Or Es Via Ethernet (External Access)

    Ethernet interface. This makes it possible to use the intranet/Internet from any location to access data or diagnostic information in the SIMOTION devices. Note Further information is contained in the SIMOTION IT Ethernet-based HMI and Diagnostic Function Diagnostics Manual. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 28: Hmi Or Es Via Profinet

    SIMOTION device. Figure 2-6 Model: Networking via PROFINET This communication does not require any settings to be made for the SIMOTION P320-3. These are made on the central HMI/ES as described in the documentation or online help for SIMOTION SCOUT.
  • Page 29: Simotion Panel Fronts

    Overview of SIMOTION panel fronts The SIMOTION panel front is a control unit for use with SIMOTION P products. It is used in conjunction with the SIMOTION P320-3 computing unit and is designed for highly demanding tasks in PC-based automation applications.
  • Page 30: Simotion P320-3 With Panel Front Via Panel Pc Remote Kit

    The SIMOTION panel fronts can only be operated via a Panel PC Remote Kit on the SIMOTION P320-3. In this case, both units must be connected together. The SIMOTION panel front is available with different control units which differ with regard to display dimensions and the inclusion of a membrane keyboard or touch screen.
  • Page 31: Simotion P320-3 Without Panel Front (Headless)

    The SIMOTION P320-3 is operated without a SIMOTION panel front, e.g. SIMOTION P320-3 installed in a control cabinet. The maintenance/configuration of the SIMOTION P320-3 is performed via a computer that accesses the SIMOTION P320-3 by means of "Remote Desktop". SIMOTION P320-3 and Panel Fronts...
  • Page 32 Description 2.4 SIMOTION panel fronts SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 33: Hardware Description

    SIMOTION P complete system SIMOTION P (SIMOTION P320-3) SIMOTION P spare parts As standard, a SIMOTION P320-3 consists of the following hardware components: ● SIMOTION PC unit SIMOTION P320-3 ● Back-up battery for the motherboard of the SIMOTION P320-3 Optional components...
  • Page 34 I/O system. A detailed, regularly updated list of the I/O modules released for SIMOTION, as well as notes on their use, can be found on the Internet at: Siemens - Industry Automation and Drive Technologies - Service & Support (http://support.automation.siemens.com/WW/view/en/11886029).
  • Page 35: Simotion P320-3 Pc Unit

    Hardware description 3.2 SIMOTION P320-3 PC unit SIMOTION P320-3 PC unit 3.2.1 SIMOTION P320-3 representation View The following diagram shows the SIMOTION P320-3. Figure 3-1 SIMOTION P320-3 SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 36 Hardware description 3.2 SIMOTION P320-3 PC unit Connection and display elements The SIMOTION P320-3 provides the following connection and display elements. Device components Description ① Cover plate for CompactFlash module ② Connection elements ③ Status indicators SIMOTION P320-3 and Panel Fronts...
  • Page 37: Connection Components

    Hardware description 3.2 SIMOTION P320-3 PC unit 3.2.2 Connection components Interfaces and power supply Position of the connection elements Designation Description ① 24 VDC Connection for a 24 VDC power supply ② DVI/VGA DVI/VGA connection for CRT or LCD monitor with DVI interface ③...
  • Page 38: Operator Controls

    Hardware description 3.2 SIMOTION P320-3 PC unit 3.2.3 Operator controls On/Off switch CAUTION The On/Off switch does not disconnect the device from the supply voltage. Position of On/Off switch Description ① The On/Off switch turns off the output voltages of the power supply but not disconnect from the supply system.
  • Page 39: Status Displays

    Carry out the licensing to correct the error. Further information on the licensing can be found in the SIMOTION P320-3 and Panel Fronts Commissioning and Hardware Installation Manual. RED: Fast flashing (2 Hz) A fault has occurred to which the user program cannot respond.
  • Page 40: Internal Components

    Hardware description 3.2 SIMOTION P320-3 PC unit 3.2.5 Internal components SIMOTION P320-3 internal structure The basic components of the device are ● the motherboard with processor, chipset, one slot for a RAM module, internal and external interfaces, ● a DC/DC converter for the power supply of the device...
  • Page 41 Hardware description 3.2 SIMOTION P320-3 PC unit Technical features of the motherboard Component/interface Description Parameters Chipset Intel GM45+ICH-9m BIOS Insyde H20... Intel Core 2 Solo 1.2 GHz, 800 MHz FSB, 3 MB SLC Memory DDR 3 SO-DIMM module 2048 MB...
  • Page 42: Simotion P320-3 Interfaces

    Industrial Ethernet DVI-I extern DVI-I standard socket DVI-I (Page 47) Memory module slot Interna Slot for CompactFlash card (X3 connector) Slot for CompactFlash card (True IDE mode) 50-pin CF socket, types I/II (Page 48) SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 43: Com Interface

    Pin no. Short designation Meaning USB_P5V_fused (O) + 5 V (fused) for external USB interface USB_D0M (I/O) Data+, USB channel 0 USB_D0P (I/O) Data-, USB channel 0 USB_GND Ground for external USB interface SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 44: Profinet Interface

    Receive data * Output 7, 8 SYMT- Internal 75 Ohm terminating resistor Shield LED 1 Lights up green: Link LED 2 Lights up yellow: Activity * Auto negotiation and auto cross over are supported SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 45 – Grid for IRT only: 125 µs – Grid for mixed RT/IRT: 0.5 ms, 1 ms, 2 ms, 4 ms ● The SIMOTION P320-3 supports a total of max. 4 KB for each input and output. ● Controller-controller data exchange broadcast: Max.
  • Page 46: Ethernet Interface

    Bi-directional data D- Input/output Shield – LED 1 Off: 10 Mbps – Lit in green: 100 Mbps Lit in orange: 1000 Mbps LED 2 Lit: Active connection – (to a hub, for example) Flashing: Activity SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 47: Dvi-I

    TMDS Clock+ DVI clock channel (O) TMDS Clock- DVI clock channel (O) Analog Red (R) Analog Red Signal (A) Analog Green (G) Analog Green Signal (A) Analog Blue (B) Analog Blue Signal (A) SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 48: Slot For Compactflash Card

    CD1#, CD2# card detect (not connected) 33, 40 VS1#, VS2# Voltage sense (not connected) DMARQ DMA Request (input) DMACK# DMA Acknowledge (output) write enable 1, 50 Ground 13, 38 + 5 V power SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 49: Simotion P State Application

    SIMOTION platforms, are displayed in virtual form in the SIMOTION P system. This is achieved via the SIMOTION P state application. The following figure shows SIMOTION P state in the started state. Figure 3-3 SIMOTION P state SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 50: Led Display

    SIMOTION SCOUT while the mode selector is set to STOP/STOPU on the SIMOTION P320-3. You must use the mode selector for this. Further information on the mode selector function can be found in the SIMOTION P320-3 and Panel Fronts Commissioning and Hardware Installation Manual.
  • Page 51: Current Operating Status

    The status LEDs and the current operating status are also displayed in the Windows task bar. Table 3- 8 Display in the task bar RUN status: Green STOP status: Yellow NOT STARTED status: Gray SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 52: Simotion Panel Fronts

    The following figure shows the front view of the SIMOTION panel front with keys. The SIMOTION P012K panel front display has a resolution of 800 x 600 pixels. Figure 3-5 SIMOTION panel front with keys variant SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 53: Function Blocks For Panels With Keys

    The control keys are used for general editing and control functions in the various applications. Figure 3-6 Control Keys Note When using SIMOTION P with a Windows operating system, you cannot enter the euro sign using the shortcut <F +8>. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 54 Numerical keypad The numerical keypad is used to enter the numbers "0" to "9", various special characters, "+" and "-", the hyphen "-", and the decimal point ".": Figure 3-8 Numerical keypad SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 55 The keyboard layout for Windows is also set up for "English/USA international". This ensures the use of standard key codes (for example, entering a "y" on the external keyboard and a "y" on the internal keyboard produces a "y" on the display in both cases). SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 56: Integrated Mouse (Only Panels With Keys)

    The parameters can be changed in "System Settings/Mouse". Figure 3-11 Integrated mouse If required, an external mouse can be connected to the front USB interface. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 57: Panels With Touch Screen View

    The panel is operated by touching the application-specific functions shown on the touch- sensitive display with your finger (for example, by pressing a button on the display). The resistive-type touch screen permits the user to operate it wearing gloves. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 58: Panels Interface Description

    The user can read the effect on the system software on the "Latency" tab in the SIMOTION P state tool. It displays there whether the installed software violates the real-time conditions. In case of doubt, please contact your local SIEMENS sales representative. Note Using a distributed configuration with the Panel PC Remote Kit reduces the data rate at the USB interface on the SIMOTION panel front.
  • Page 59 (distributed configuration) as well as the USB cable, have to be connected to the interfaces on the remote module (see SIMOTION P320-3 and Panel Fronts Commissioning and Hardware Installation Manual). Removing this metal plate reveals the rear side of the panel front as shown in the figure.
  • Page 60: Technical Data For Simotion Panel Fronts

    - in inches 17.72 x 11.42 x 3.9 14.49 x 11.42 x 4.92 17.72 x 11.42 x 5.12 Weight Approximately 6 kg Approximately 6 kg Approximately 6 kg Depth with computer unit mounted SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 61 Supply air No corrosive gases Table 3- 12 Mechanical stress Vibration and shock stressing in operation Tested according to EN 60721-3-3, class 3M4 See also Technical specifications of additional hardware components (Page 111) SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 62: Simotion Panel Fronts Accessories

    6AV7671-2BA00-0AA0 for 12'' touch screen (10 units)  6AV7671-4BA00-0AA0 for 15'' touch screen (10 units)  Film for labeling the function keys (10 units) 6AV7672-0DA00-0AA0 Accessories can be ordered online at http://www.siemens.com/automation/mall SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 63: Distributed Configuration With The Panel Pc Remote Kit

    The Panel PC Remote Kit for a distributed configuration enables spatial separation between SIMOTION panel fronts and the SIMOTION P320-3. After power-up, you can operate the SIMOTION P320-3 in the same manner as with the operator panel connected directly to the SIMOTION P320-3. All keys have the same action as for the directly connected operator panel.
  • Page 64: Configurations

    Using a distributed configuration with the Panel PC Remote Kit reduces the data rate at the USB interface on the SIMOTION panel front. Configuration for distances up to 5 m Figure 3-15 Configuration: Panel front using the Panel PC Remote Kit on the SIMOTION P320-3 (≤ 5 SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 65 3.6 Distributed configuration with the Panel PC Remote Kit Configuration for distances between 5 m and 30 m Figure 3-16 Configuration: Panel front using the Panel PC Remote Kit on the SIMOTION P320-3 (> 5 m) SIMOTION P320-3 and Panel Fronts...
  • Page 66: Interface Description For The Panel Pc Remote Kit

    (24 + 5)-pin socket ⑥ I/O USB interface 2 x 13-pin plug connector USB 2.0 interface USB-A LVDS display interface X300 2 x 10-pin plug connector For the connection of a panel front SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 67: Technical Data For The Panel Pc Remote Kit

    20-pin plug connector for the LVDS display cable K2 for connecting the panel front Unless explicitly specified, you can obtain the pin assignment for the connections from section: SIMOTION P320-3 interfaces (Page 42). 3.6.4 Technical data for the Panel PC Remote Kit...
  • Page 68: Accessories For The Panel Pc Remote Kit

    Order No. Mounting SIMOTION P320-3 Mounting brackets for the 1 set A5E00417699 bracket SIMOTION P320-3 in the control cabinet (2 units) Book mounting kit for the 6ES7648–1AA20–0YB0 SIMOTION P320-3 in the control cabinet Cable Cable set for 5 m; DVI-D and USB cable 6AV7671–1EX10-5AA0...
  • Page 69: Application Planning

    ● Check the packaging and the package content for any visible transport damage. ● Verify that the shipment contains the complete device and your separately ordered accessories. Please inform your local dealer of any disagreements or transport damages. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 70 (<F2> key) at Main > Hardware Options ● Microsoft Windows "Product Key" from the "Certificate of Authenticity" (COA): The COA label is attached to the rear side of the device. Figure 4-1 COA Label Windows Embedded Standard 2009 SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 71: Ambient And Environmental Conditions

    ● Do not cover the ventilation slots of the device. ● Always observe the mounting positions permitted for this device. ● The connected or installed I/O must not generate a reverse voltage greater than 0.5 V in the device. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 72: Mounting Positions And Fastening

     Below at least 100 mm  Above at least 50 mm Mounting positions Table 4- 1 Permissible mounting positions for the SIMOTION P320-3 Mounting position Permitted temperatures / notes Horizontal (preferred position) in RAL: 0 to +55° C...
  • Page 73: Permissible Mounting Positions Of The Panel Front

    In the event of deviations from it, you might need to have additional tests carried out to verify compliance with the general conditions applicable for the components used (e.g. temperature). Siemens can provide appropriate support on request. SIMOTION P320-3 and Panel Fronts...
  • Page 74: Type Of Fixation

    Degree of protection IP65 The IP65 degree of protection is only provided for a clamp mounting together with a ring seal. Degree of protection IP54 This degree of protection is provided for screw mounting. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 75: Installing/Mounting

    Control Equipment (UL508). A UL508 conform enclosure is therefore a mandatory requirement for approval or operation according to UL508. Types of installation The following SIMOTION P320-3 installation types are permitted and described in the following sections: ● Mounting onto standard rail (Page 76) ●...
  • Page 76: Mounting On Din Rails

    5.1.2 Mounting on DIN rails Mounting the device on standard rails Note Use of Siemens 35 mm standard mounting rail is recommended. Steps for mounting on standard rail Set the device inclined on the standard rails. Swing the device fully onto the rails until both clamps completely latch.
  • Page 77: Mounting With Mounting Brackets

    Two mounting clamps are factory installed on the device for mounting onto standard rail. These need to be removed before mounting the mounting brackets. Steps for removing the mounting clamps ② Remove the four screws ① the two mounting clamps from the back of the device. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 78 Metal screws M 4: 4 mm diameter (min. 2 mm thick) 15 mm length WARNING Ensure that the wall or ceiling can hold four times the total weight of the device (including the mounting brackets and additional expansion modules). SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 79: Upright Mounting

    Table 5- 1 Spare parts and accessories Parts for the SIMOTION P320-3 Order No. Scope of Accessories delivery Book mounting kit 6ES7648-1AA20-0YB0 You can order the book mounting kit via the Siemens A&D Mall (http://www.siemens.com/automation/mall). SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 80: Installing/Removing An Accessible Compactflash Card

    CF card. Exit the running software applications via the menu Start > Shut down, switch the device off via the ON/OFF switch and disconnect the device from the power supply. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 81 ESD guidelines (Page 141). Opening the module receptacle To open the module receptacle, turn the ① cover plate of the module receptacle 180 degrees counter-clockwise. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 82 If the CF card meets resistance, flip it over. Never insert the CF card with force. Removing the CompactFlash card Steps for removing a CF card Open the module receptacle. ① Press the eject button and remove the CF card. Close the module receptacle again. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 83 Installing/Mounting 5.2 Installing/removing an accessible CompactFlash card See also Slot for CompactFlash card (Page 48) Available spare parts and accessories (Page 133) SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 84: Assembly Forms Overview

    The installation is in a distributed configuration, i.e. the panel is connected to the SIMOTION P320-3 in different physical locations. This requires several additional components that must be attached to the panel front or the SIMOTION P320-3. As an alternative, the SIMOTION P320-3 can be installed without panel front (headless).
  • Page 85: Distributed Configuration

    The distributed configuration makes it possible to connect SIMOTION panel fronts in different physical locations to a SIMOTION P320-3. The greater flexibility in terms of location allows the SIMOTION P320-3 to be positioned in non-critical areas of a plant (e.g. control cabinet).
  • Page 86: Components For Decentralized Structure

    ● USB transmitter module for cable lengths > 5 m ● Installation-specific mounting kits, such as – Flat mounting brackets for fastening the SIMOTION P320-3 in the control cabinet – Book mounting brackets for fastening the SIMOTION P320-3 in the control cabinet 5.4.3...
  • Page 87 Ready-mounted remote module on the SIMOTION panel front See also Interface description for the Panel PC Remote Kit (Page 66) Accessories for the Panel PC Remote Kit (Page 68) Panels interface description (Page 58) Connection components (Page 37) SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 88: Mounting The Simotion Panel Front

    The SIMOTION P012T panel front can only be installed using latch fasteners. Tension jacks with setscrews The side view of the mounting brackets shows the projections that hook into the mounting slots on the panel front. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 89 Consequently, you should ensure strict compliance with the specified values. Note The mounting depth increases by 21 mm when an optical drive is installed in the device. Take the dimensions from the dimension drawings. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 90: Securing The Panel Front With Screws

    Skip this step if you have selected "Fasten panel front with clamps" (Page 88). NOTICE Securing with screws is not possible with the 12" touch screen variant (SIMOTION P012T). Requirement The mounting cutout has been opened. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 91 5. Secure the control unit by inserting suitable screws through the holes and attaching nuts (torque 0.4 ... 0.5 Nm). Note The mounting depth increases by 21 mm when an optical drive is installed in the device. Take the dimensions from the dimension drawings. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 92 Installing/Mounting 5.5 Mounting the SIMOTION panel front SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 93: Connecting

    ● Install the device in such a way that it poses no danger, for example, by falling over. ● The clearance around the SIMOTION P320-3 must be at least 50 mm above and 100 mm below to ensure adequate ventilation.
  • Page 94: Overview Of Connections

    Figure 6-1 Hardware system overview - example with PROFINET onboard controller The figure shows the SIMOTION P320-3 interfaces to which appropriate I/Os can be connected. Any cabling made to all elements and components of the complete system may be done only when disconnected from the mains.
  • Page 95: Connecting Peripheral Equipment

    Generation of reverse voltage greater than 0.5 V to ground on + 3.3 VDC / + 5 VDC / + 12 VDC at a connected or installed component can prevent normal operation or destroy components of the device. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 96: Connecting The 24 V Dc Power Supply

    1. Switch off the 24 VDC power source. 2. Connect the power supply using the plug (included in the package). 3. Connect the PE conductor. Figure 6-2 Connecting the device to the 24 VDC power supply SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 97: Protective Ground Connection

    (large contact surface) to the PE conductor on the cabinet or system in which the PC will be installed. The minimum conductor cross-section may not be less than 5 mm Figure 6-3 Connecting the protective earth SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 98: Usb Strain-Relief

    1. Fasten the USB strain-relief to the device housing with an oval-head screw (M4 thread). ② 2. Thread the cable tie through the comb of the USB strain-relief to fasten the USB cable. Figure 6-4 USB strain-relief SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 99: Profinet Strain Relief

    One cable tie (not included in the package) is required for each interface. To fix the PROFINET strain relief, you will need a TORX T10 screwdriver. Attaching the PROFINET strain relief Attach the PROFINET strain relief. Attach the cable using the cable tie. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 100 Connecting 6.7 PROFINET strain relief SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 101: Service And Maintenance

    Note A backup battery maintains the contents of the SRAM data on the SIMOTION P320-3 after the power supply is switched off. SIMOTION P320-3 and Panel Fronts...
  • Page 102 1. If necessary, note any specific BIOS setup settings if changes have been made. 2. Isolate the device from the power supply and disconnect all connecting cables. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 103 As a result of replacing the battery (SRAM not backed up during this time), data loss may occur in the SRAM of the SIMOTION P320-3. 1. To avoid a lengthy repeat of the commissioning procedure, ensure that a backup of the non-volatile data is available before changing the battery.
  • Page 104 30 seconds when the device is switched off, the BIOS settings will be retained. The SRAM and CMOS data of the SIMOTION P320-3 is certainly deleted only when the battery is disconnected for a longer period of time (more than 15 minutes) and in the switched-off state.
  • Page 105: Troubleshooting/Faqs

    OK, the time and date dead. (Page 101)). are still wrong. If the problem is not corrected by replacing the battery, then contact your technical support team in this case (see Hotline and Internet addresses (Page 5)). SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 106 The EWF for Windows Embedded Standard 2009 must first be disabled for this purpose. IP address assigned twice Default IP address for Assign a new IP address for Windows (see SIMOTION P320-3 (e.g. through series Windows (see and Panel Fronts Commissioning and Hardware Installation commissioning).
  • Page 107: Technical Data

     Relative humidity Tested acc. to IEC 60068-2-78, IEC 60068-2-30 During operation 5% to 80% at 25° C (no condensation)   Storage/transport 5% to 95% at 25° C (no condensation)   SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 108 400, 10/100 Mbps electrically isolated Ethernet 1x Ethernet interface (RJ45) Intel 82574L 100/1000 Mbps, electrically isolated For unambiguous labeling, the LAN interfaces are numbered on the housing. The numbering by the operating system can differ. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 109 No license exists for technology/optional objects under license. Carry out the licensing to correct the error. Further information on the licensing can be found in the SIMOTION P320-3 and Panel Fronts Commissioning and Hardware Installation Manual. RED: Fast flashing (2 Hz) A fault has occurred to which the user program cannot respond.
  • Page 110: Power Requirements Of The Components

    Note Inrush current A minimum of 4.5 A inrush current for 15 ms is required for starting the SIMOTION P320-3. The peak value of the inrush current depends on the input voltage and the impedance of the 24 V source; peak values higher than 4.5 A are possible. This will not inhibit the operation of the SIMOTION P320-3.
  • Page 111: Technical Specifications Of Additional Hardware Components

    Technical data of additional hardware components can be found at: ● Technical data for SIMOTION panel fronts (Page 60) ● Technical data for the SITOP smart 24 V / 10 A (Page 128) SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 112: Keyboard Table (For Keyboard Panel Version Only)

    0x06 0x38/s 0x05 0x27/s 0x04 0x26/s 0x42 0x40/s F19 (Shift F7) 0x0f 11a1 0x35 ‘ 0x0e 12a1 0x34/a ’ 0x0d 13a1 0x34 ’ 0x0c 14a1 0x34/s " 0x0b 15a1 0x30 0x0a 16a1 0x2f SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 113 0x18 30a1 0x33/s 0x17 31a1 0x33 0x16 32a1 0x36 0x3f 0x3d/s F16 (Shift F4) 0x23 35a1 0x23/s 0x22 36a1 0x37/s > 0x21 37a1 0x36/s < 0x1b 0x1a 0x19 0x3e 0x3c/s F15 (Shift F3) SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 114 (CURSOR RIGHT) 0x4a (HOME) 0x50 (CURSOR LEFT) 0x4c (DELETE) 0x3a 0x44 0x3a/a (ACK - ALT F1) 0x28 (ENTER) 0x51 (CURSOR DOWN) 0x0b/a (HELP) 0x2b (TAB) 80A1 0x2b/s (SHIFT TAB) 0x00/c (CONTROL) 0x00/s (SHIFT) SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 115 S8 (Control F4) 0x3e/c,9 S9 (Control F5) 0x3f/c,10 S10 (Control F6) 0x40/c,11 S11 (Control F7) 0x41/c,12 S12 (Control F8) 0x42/c,13 S13 (Control F9) 0x43/c,14 S14 (Control F10) 0x44/c,15 S15 (Control F11) 0x45/c,16 S16 (Control F12) SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 116 Technical data 9.5 Keyboard table (for keyboard panel version only) SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 117: Dimension Drawings

    ● Dimensional drawings of the device with book mounting bracket (Page 121) Note The dimensions are always given in mm and inch (top: Millimeter, bottom: Inch) 10.1.2 Dimension drawings of the device Figure 10-1 Dimension drawing of the device: Front view SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 118 Dimension drawings 10.1 SIMOTION P320-3 dimensions Figure 10-2 Dimension drawing of the device: Side view See also Panel front dimensions (Page 122) SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 119: Dimension Drawings Of The Device With Mounting Brackets

    Dimension drawings 10.1 SIMOTION P320-3 dimensions 10.1.3 Dimension drawings of the device with mounting brackets Figure 10-3 Dimension drawing of the device with mounting brackets: Front view and top view SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 120 Dimension drawings 10.1 SIMOTION P320-3 dimensions Figure 10-4 Dimension drawing of the device with mounting brackets: Side view SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 121: Dimensional Drawings Of The Device With Vertical Mounting Angles

    Dimension drawings 10.1 SIMOTION P320-3 dimensions 10.1.4 Dimensional drawings of the device with vertical mounting angles Figure 10-5 Dimension drawings of the device with book mounting brackets SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 122: Panel Front Dimensions

    The following dimension drawing shows the device dimensions of the SIMOTION panel fronts in [mm]. All dimensions are specified without screw protrusions. Figure 10-6 SIMOTION panel fronts device dimensions Panel fronts With keys: P012K With touch screen: P012T P015T SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 123: Simotion Panel Fronts Installation Dimensions

    The following dimension drawings show the installation dimensions of the panel fronts in [mm]. Installation dimensions for SIMOTION P012K Figure 10-7 Installation dimensions for SIMOTION P012K SIMOTION P012T installation dimensions Figure 10-8 SIMOTION P012T installation dimensions - dimensions in [mm] SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 124 Dimension drawings 10.3 SIMOTION panel fronts installation dimensions SIMOTION P015T installation dimensions Figure 10-9 SIMOTION P015T installation dimensions SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 125: Dimensional Drawing Of Simotion Panel Front With Panel Pc Remote Kit

    101,5 47,0 35,8 82,3 37,8 15" Touch 310,3 482,6 288,3 273,0 265,2 447,2 171,0 99,2 47,0 33,1 79,6 48,1 12" Keys 310,3 482,6 288,3 273,0 265,2 447,2 171,0 83,0 48,0 16,3 63,8 29,3 SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 126 Dimension drawings 10.4 Dimensional drawing of SIMOTION panel front with Panel PC Remote Kit SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 127: Spare Parts/Accessories

    Power supply 11.1.1 Over of power supply An external power supply is needed to connect the SIMOTION P320-3 to the network. The power supply must provide the following values for the SIMOTION P320-3: Output voltage: 20.4 ... 28.8 VDC, typically 24 V Output power: Typically 40 W (SIMOTION P320-3 alone), max.
  • Page 128: Example: Sitop Smart 24 V/10 A

    11.1 Power supply 11.1.2 Example: SITOP smart 24 V/10 A The SITOP smart 24 V / 10 A power supply meets all requirements of a SIMOTION P320-3 and is therefore ideal for this application. Figure 11-1 View of the SITOP smart 24 V/10 A 11.1.3...
  • Page 129 UL 508 (Listed, File E197259); CSA C22.2 No. 14, No. 60950-1-03 Shipbuilding Germanischer Lloyd Directive 94/9/EC Declaration of conformity acc. to EN 60079-15: ATEX94/9/EC Cat.3;Eex, nA, II, T4 U C-Tick AS/NZS 2064:1997 Order numbers 6EP1334-2AA01, 6EP1334-2BA01 SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 130: Ups System

    UPS system is strongly advised. Otherwise, there is a risk of the Windows installation sustaining damage, and it may no longer be possible to execute SIMOTION P. Figure 11-2 SITOP DC UPS module with accumulator module SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 131: Sitop Dc Ups Module

    The UPS module uses the USB data interface to forward information to the SIMOTION P; this can subsequently be displayed with the UPS monitoring application. Figure 11-4 Power supply overview SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 132: Accessory Kit

    24 V power supply connector 11.4 Accessories for the hardware components The accessories of the SIMOTION P320-3 hardware components are described in the following sections: ● SIMOTION panel fronts accessories (Page 62) ● Accessories for the Panel PC Remote Kit (Page 68)
  • Page 133: Available Spare Parts And Accessories

    6ES7648-1AA20-0YB0 Note Only SIMATIC PC CompactFlash cards with product version 02 (ES 02) can be used for this device. You can order the accessories via the Siemens A&D Mall (http://www.siemens.com/automation/mall). Spares On Web Spares On Web (http://workplace.automation.siemens.de/sparesonweb) is an information system that enables you to find out which spare parts are available for your device.
  • Page 134 Spare parts/Accessories 11.5 Available spare parts and accessories SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 135: Standards And Approvals

    Shielded Cables Shielded cables must be used with this equipment to maintain compliance with FCC regulations. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 136 There is a risk of injury or of damage to assets. In hazardous areas, personal injury or damage to assets can occur if plug-in connections are disconnected during operation. Make sure that your system is always de-energized before disconnecting plug-in connections in hazardous areas. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 137: Safety Of Electronic Controllers

    In this respect, the basic measures listed above are no longer adequate once the hazard exceeds a certain potential. Additional measures (e.g. double redundancy, tests, checksums, etc.) for the controller must implemented and certified (DIN VDE 0801). SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 138 5. Release of environmental pollutants or emissions as a result of improper operation of the system and/or failure to dispose of components safely and correctly SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 139: Certificates

    A.3 Certificates Certificates DIN ISO 9001 certificate The Siemens quality management system for all production processes (development, production and sales) meets DIN ISO 9001:2000 requirements. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 140 Standards and approvals A.3 Certificates SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 141: Esd Guidelines

    Any damage that occurs to a module as a result of overvoltage is generally not recognized immediately and only comes to light after the equipment has been operating for some time. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 142: Electrostatic Charging Of Individuals

    This figure indicates the maximum electrostatic charges that can accumulate on an operator when he comes into contact with the indicated materials. These values comply with the specifications in IEC 801-2. Figure B-2 Electrostatic voltage that can accumulate on operating personnel SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 143: Basic Measures For Protection Against Discharge Of Static Electricity

    If you have to take measurements on a module, make sure that you first discharge any static that may have accumulated in your body. To do this, touch a grounded metal object. Only use grounded measuring instruments. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 144 ESD guidelines B.3 Basic measures for protection against discharge of static electricity SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 145: List Of Abbreviations

    Human Machine Interface User interface Hardware Input/Output Data input/output on computers Integrated Device Electronics International Electronical Commission Ingress Protection Degree of protection Local Area Network Computer network that is limited to a local area. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 146 User Mode Driver Framework Universal Serial Bus Uninterruptible power supply (UPS) Positive supply voltage of integrated circuits Video Graphics Array Video adapter which meets industrial standard Watchdog Program monitoring with error detection and alarming. SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 147: Index

    Clamp, 88 Connection via PROFINET, 24 COM interface, 43 Drives, 108 CompactFlash card DVI-I interface, 47 Installing, 82 Removal, 82 Replacing, 80 Components Electromagnetic compatibility, 135 SIMOTION P320-3, 33 Electrostatic sensitive devices, 12 Connecting SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 148 Panel PC Remote Kit, 66 Operating status Interfaces, 37, 108 SIMOTION P state, 51 COM, 37, 43 Operator components, 25 CompactFlash card, 48 Optional components, 25 DVI/VGA, 37 Order No., 70 DVI-I, 47 Overview of connections, 94 SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 149 SIMOTION P state, 49 USB interface, 43 LED displays, 50 USB strain-relief, 98 Mode selector, 50 USER profile Operating status, 51 BIOS Setup, 104 SIMOTION P320-3 Layout, 36 SIMOTION P320-3 backup battery, 101 SIMOTION P320-3 and Panel Fronts Manual, 02/2012...
  • Page 150 Index Vent slots, 71 View Panel with keys, 52 Panel with touch screen., 57 Warranty, 11 Weight, 60, 107 Windows Embedded Standard 2009 Device functions, 18 SIMOTION P320-3 and Panel Fronts Manual, 02/2012...

Table of Contents