Nortel Ethernet Routing Switch 8600 Installation Manual page 60

Chassis
Hide thumbs Also See for Ethernet Routing Switch 8600:
Table of Contents

Advertisement

60 8010co chassis installation
Procedure steps
Step
1
2
3
4
5
6
7
Copyright © 2008 Nortel Networks
.
Action
Place the installation shelf at the bottom of the rack inside the
rails.
Hold the installation shelf in position and align the mounting rail
with the two holes on each side of the vertical rack support.
Insert a Phillips screw through each installation shelf mounting
hole and into the corresponding hole in the rack.
For more information about installing the shelf, see
"Installing the installation shelf in a 19-in. equipment rack" (page
60).
Figure 31
Installing the installation shelf in a 19-in. equipment rack
Add a hex nut to each screw and tighten by using a hex wrench.
Tighten each screw with a Phillips screwdriver.
If the holes in the vertical supports require clip nuts, insert a clip
nut in each of the 12 locations.
WARNING
Risk of personal injury
It requires three people to lift the 8010co chassis. To
make the chassis lighter, remove the modules and
power supplies before you lift it.
Lift the 8010co chassis onto the installation shelf.
Nortel Ethernet Routing Switch 8600
Installation — Chassis
NN46205-303 02.01 Standard
30 May 2008
Figure 31