Page 2
While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.
Read the information in this section to learn about regulatory conformities and compliances. International Regulatory Statements of Conformity This is to certify that the Nortel 8000 Series chassis and components installed within the chassis were evaluated to the international regulatory standards for electromagnetic compliance (EMC) and safety and were...
Page 8
EN 55 024 Statement This is to certify that the Nortel 8000 Series chassis is shielded against the susceptibility to radio interference in accordance with the application of Council Directive 2004/108/EC. Conformity is declared by the application of EN 55 024 (CISPR 24).
Page 9
Class A requirements of the Republic of Korea Ministry of Information and Communications (MIC). This device may not be sold for use in a non-business application. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
CE Marking Statement (Europe only) EN 60 950 Statement This is to certify that the Nortel 8000 Series chassis and components installed within the chassis are in compliance with the requirements of EN 60 950 in accordance with the Low Voltage Directive. Additional national differences for all European Union countries have been evaluated for compliance.
This section describes the different precautionary notices used in this document. This section also contains precautionary notices that you must read for safe operation of the Nortel Ethernet Routing Switch 8600. Notices Notice paragraphs alert you about issues that require your attention.
Page 14
14 Regulatory Information and Safety Precautions CAUTION ATTENZIONE ESD Le indicazioni ESD forniscono informazioni per evitare scariche di elettricità statica e i danni correlati per i prodotti Nortel. Caution Notice CAUTION Caution notices provide information about how to avoid possible service disruption or damage to Nortel products.
Page 15
Nortel. WARNING AVISO Os avisos oferecem informações sobre como evitar ferimentos ao trabalhar com os produtos da Nortel. WARNING AVVISO Le indicazioni di avviso forniscono informazioni per evitare danni alle persone durante l’utilizzo dei prodotti Nortel.
30 days of purchase to obtain a credit for the full purchase price. "Software" is owned or licensed by Nortel Networks, its parent or one of its subsidiaries or affiliates, and is copyrighted and licensed, not sold. Software consists of machine-readable instructions, its components, data, audio-visual content (such as images, text, recordings or pictures) and related licensed materials including all whole or partial copies.
Page 20
Upon termination or breach of the license by Customer or in the event designated hardware or CFE is no longer in use, Customer will promptly return the Software to Nortel Networks or certify its destruction. Nortel Networks may audit by remote polling or other reasonable means to determine Customer’s Software activation or usage levels.
Page 21
Customer fails to comply with the terms and conditions of this license. In either event, upon termination, Customer must either return the Software to Nortel Networks or certify its destruction. Customer is responsible for payment of any taxes, including personal property taxes, resulting from Customer’s use of the Software.
New in this release The following sections detail what’s new in Nortel Ethernet Routing Switch 8600 Installation — Chassis, NN45205-303 for Release 5.0: • “Features” (page 23) • “Other changes” (page 24) Features For information about changes that are feature-related, see the following sections: •...
Air filter Information about the air filter in the 8010co chassis is removed. For more information about installing an air filter, see Nortel Ethernet Routing Switch 8600 Installation — 8010co Chassis Air Filter, NN46205-318. For more information about replacing an air filter, see Nortel Ethernet Routing Switch 8600 Routine Maintenance , NN46205-312.
This document provides the instructions to install the Ethernet Routing Switch 8600 chassis in an equipment rack. This document also describes some of the routine tasks to operate the Ethernet Routing Switch 8600 and includes technical specifications for the chassis and modules.
Chassis installation fundamentals Each Ethernet Routing Switch 8600 chassis consists of a sheet metal enclosure, a backplane, and a fan interface backplane. The number of bays for power supplies and the number of fan trays and cooling modules depends on the chassis type.
Slots are numbered from left to right. You can install Ethernet Routing Switch 8600 interface modules in slots 1 through 4 and in slots 7 through 10. Slots 5 and 6 are reserved for Ethernet Routing Switch 8600 SF/CPU modules.
The 8010co chassis supports the following DC power supplies: • 8004DC • 8005DC If your Ethernet Routing Switch 8600 is operating in a redundant power configuration, you can upgrade the Ethernet Routing Switch 8600 for additional power while the Ethernet Routing Switch 8600 remains in operation. CAUTION The output power ratings differ between power supply models.
Page 30
R or RS modules installed in the 8006, 8010, or 8010co chassis require a minimum of one 8005AC, 8005DI AC, or 8005DC power supply. If your Ethernet Routing Switch 8600 is operating in a redundant power configuration, you can upgrade the Ethernet Routing Switch 8600 for additional power while the Ethernet Routing Switch 8600 remains in operation.
For information about power supply installation, see Nortel Ethernet Routing Switch 8600 Installation — AC Power Supply, NN46205-306 or Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply, NN46205-307. The 8010 chassis uses two fan trays for cooling. For information about fan trays, see Nortel Ethernet Routing Switch 8600 Routine Maintenance, NN46205-312.
R or RS modules installed in the 8006, 8010, or 8010co chassis require a minimum of one 8005AC, 8005DI AC, or 8005DC power supply. If your Ethernet Routing Switch 8600 is operating in a redundant power configuration, you can upgrade the Ethernet Routing Switch 8600 for additional power while the Ethernet Routing Switch 8600 remains in operation.
The 8003 chassis uses two bays for 8003AC power supplies and a single 8003 fan tray for cooling. For more information about the power supply and fan tray, see Nortel Ethernet Routing Switch 8600 Installation — AC Power Supply, NN46205-306 and Nortel Ethernet Routing Switch 8600 Routine Maintenance, NN46205-312.
34 Chassis installation fundamentals If your Ethernet Routing Switch 8600 is operating in a redundant power configuration, you can upgrade the Ethernet Routing Switch 8600 for additional power while the Ethernet Routing Switch 8600 remains in operation. CAUTION The output power ratings differ between power supply models.
For fan trays, a control or monitor circuit board in the fan tray reports temperature and the status of fan operation to the network management software. A green light emitting diode (LED) indicates correct fan operation. For information about installing fan trays, see Nortel Ethernet Routing Switch 8600 Routine Maintenance, NN46205-312. Site requirements Ensure that the installation site meets the space requirements listed in this section.
Page 38
AT-compatible modem to allow dial-in access to startup configuration and diagnostics. Cables Unless you specifically order them, Nortel does not include the cables required for your network configuration in the chassis accessory package. If you need the proper cables, contact your network administrator.
Page 40
The following sections describe these items. Before you install the 8010co hardware, ensure that you obtain all the cables, tools, and other equipment you need. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
If the rack does not use threaded rail holes, you must use the supplied clip nuts with the clip nut screws. Cables Unless you specifically order them, Nortel does not include the cables required for your network configuration in the 8010co chassis accessory package. If you require the proper cables, contact your network administrator.
Page 42
Contact your network administrator to verify that the Ethernet Routing Switch 8600 is now connected to the network. If the LEDs do not light in this sequence, contact your local Nortel Technical Solutions Center. Nortel Ethernet Routing Switch 8600 Installation —...
Prerequisites to chassis installation • Inspect all items for shipping damage. If you find items that are damaged, do not install the chassis. Call the Nortel Technical Solutions Center in your area. • Verify that the items in the shipping container match those on the shipment packing list.
5 in. (12.7 cm) at the front for power cord clearance. Attach rubber feet to each marked location on the bottom of the chassis. The rubber feet are optional but Nortel recommends that you use them to help keep the unit from moving. --End-- Mounting the chassis in an equipment rack Mount the chassis in a standard 19 in.
Prerequisites to chassis installation • Inspect all items for shipping damage. If you find items that are damaged, do not install the chassis. Call the Nortel Technical Solutions Center in your area. • Verify that the items in the shipping container match those on the shipment packing list.
Page 60
It requires three people to lift the 8010co chassis. To make the chassis lighter, remove the modules and power supplies before you lift it. Lift the 8010co chassis onto the installation shelf. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
Page 61
Installing the 8010co chassis in a 19-in. two-post rack Make sure that the hole pairs on either side of the vertical support match horizontally. Tighten each screw with a Phillips screwdriver. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
Page 62
Figure 33 "Two 8010co chassis with BIP in a two-post rack" (page shows two 8010co chassis with a BIP installed in a two-post rack. Figure 33 Two 8010co chassis with BIP in a two-post rack Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
Insert eight screws through the cable management bracket and tighten into chassis. For more information, see the following figure. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
Page 64
To install side cable management brackets, slide the keyed attachments into slots on either side of the card cage. Figure 34 "Installing cable management brackets" (page 64). Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
Action Install the 8010co chassis as described in previous procedures. Install the 8004DC power supplies as described in Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply, NN46205-307. Install the BIP as described in Nortel Ethernet Routing Switch 8600 Installation — Breaker Interface Panel, NN46205-313.
Page 69
The following figure shows an example of how to ground two 8010co chassis. In this example, each chassis uses three AC power supplies. Figure 38 Chassis and AC power supply grounding example Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
Switch operations This section describes some of the routine tasks you perform to operate the Ethernet Routing Switch 8600. Switch operations navigation • “Powering on DC power supplies” (page 71) • “Powering on AC power supplies” (page 73) • “Resetting the switch” (page 73) •...
Resetting the switch 73 If the problem persists, contact the Nortel Technical Solutions Center. --End-- Powering on AC power supplies Power on the AC power supplies to provide power to the switch. Procedure steps Step Action Verify that the AC power cords connect to AC power outlets.
Removing removable flash memory cards Remove a flash memory card from the 8691 SF/CPU module or the 8692 SF/CPU module to stop using it as a storage medium. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
Typically, you do not operate a Ethernet Routing Switch 8600 with a write-protected memory card. Make a copy of your configuration on another memory card, write-protect the second card, and store it in a safe place.
Page 78
Insert the card into the card receptacle. Gently push in the card until it fits tightly in place. --End-- Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
Remove the power supply filler panels. For more information, see Nortel Ethernet Routing Switch 8600 Installation — AC Power Supply, NN46205-306 or Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply, NN46205-307. Remove the module filler panels. For more information, see Nortel Ethernet Routing Switch 8600 Installation —...
Part numbers The following table lists Ethernet Routing Switch 8600 hardware and part numbers. Part number Item Additional details DS1400001 8010co chassis Breaker Interface Support for one or two 8010co Panel (BIP) chassis. Includes rack level alarms and cabling from BIP to chassis.
(MIL-std 217 standard) Model 8005AC power supply This section provides power ratings for the 8005AC power supply. The following table lists the AC input power specifications. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
1850 BTU/hour If you install a Breaker Interface Panel (BIP), the installation site must meet the electrical requirements for DC power shown in the following table. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
You can also calculate chassis and module power consumption using the Nortel ERS 8600 Power Supply Calculator (NN48500-519), available on the Nortel Technical Support Web site. You can find the calculator at www.nortel.com/documentation. Choose Routers & Routing Switches, and then Ethernet Routing Switch 8600.
Power supply selection The following table lists the power available from each power supply supported with the Ethernet Routing Switch 8600. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard...
8010co chassis 91 Release 5.0 of the Ethernet Routing Switch 8600 offers improved power management. Power management identifies the available power in the chassis, called the power budget, and determines if enough power is available to operate the installed components. For a complete description of the power management feature and configuration instructions, see Nortel Ethernet Routing Switch 8600 Administration, NN46205-605.
área residencial provavelmente causará interferência prejudicial; neste caso, espera-se que os usuários tomem as medidas necessárias para corrigir a interferência por sua própria conta. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
(ESD) quando estiver realizando a manutenção deste produto. Certifique-se de que a pulseira esteja em contato com sua pele. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
Nunca mire un puerto de fibra óptica o conector. Siempre asuma que los cables de fibra óptica están conectados a una fuente de luz. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
Riesgo de lesiones Se necesitan tres personas para levantar el chasis de 8010co. Para alivianar el peso, retire los módulos y las fuentes de alimentación antes de levantarlo. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
Page 107
Rischio di lesioni personali Per sollevare lo chassis 8010co, sono necessarie tre persone. Per alleggerire lo chassis, rimuovere i moduli e gli alimentatori prima di sollevarlo. Nortel Ethernet Routing Switch 8600 Installation — Chassis NN46205-303 02.01 Standard 30 May 2008...
Page 112
While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.
Need help?
Do you have a question about the Ethernet Routing Switch 8600 and is the answer not in the manual?
Questions and answers