Testmode; System; Dram; Speaker - Canon MF4500 Series Service Manual

Table of Contents

Advertisement

TESTMODE

SYSTEM

■ DRAM

TESTMODE>SYSTEM>DRAM
Sub item
TEST1
Data read/write check for DRAM (except system work area)

■ SPEAKER

TESTMODE>SYSTEM>SPEAKER
Sub item
Description
ON
Volume level is stepped up by 1 from minimum to maximum
every time pressing OK key. When the volume level is reached
to maximum, it changes to silence and minimum volume.
MIN
Play with minimum volume by pressing OK key.
MAX
Play with maximum volume by pressing OK key.
8
Service Mode > TESTMODE > SCAN > SENSOR
Description
T-8-41
FAX model only
Yes
Yes
Yes
T-8-42
8
Service Mode > TESTMODE > SCAN > SENSOR

SCAN

■ ADJUST

● ADF-ADJ
TESTMODE>SCAN>ADJUST>ADF-ADJ
Sub item
Description
DF-SPEED
Enter the adjustment value for the magnification ratio in vertical
scanning direction in stream feeding
Setting range: -200 ~ 200
DF-OFFSET
Enter for the adjustment of DF original stop position
Setting value: -30 ~ 30

■ SENSOR

TESTMODE>SCAN>ADJUST>SENSOR
Sub item
TRAY PAPER SENS
Display the status of Multi Pickup Sensor
1: Paper existing
0: No paper
REGI SENS
Display the status of Leading Edge Sensor
1: Paper existing
0: No paper
ESS DOOR SENS
Display the status of Delivery Tray Open/ Close Switch
1: ON
0: OFF
8-15
ADF model only
Yes
Yes
T-8-43
Description
T-8-44
8-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D500 seriesMf4400 series

Table of Contents