Introduction; About This Manual; New Features; Main Features - Paradox 728ULT Reference & Installation Manual

Hide thumbs Also See for 728ULT:
Table of Contents

Advertisement

1.1

About This Manual

This manual provides all the information you will need to understand panel operation, features and functions. If you are familiar
with other security control panels, we recommend that you read this manual at least once to familiarize yourself with panel
features and programming. Please refer to the index for a complete list of this manual's contents.
Programming method used to program
this feature
6.15
Report Zone Restore Options
Feature Select Programming
Default: Zone Restore Codes Transmit on Bell Cut-Off
With the [
BYP
transmit if the zone has returned to normal after bell cut-off (see Bell Cut-Off Time on page 34). With the [
codes will transmit as soon as the zone returns to normal (zone closure).
Key [
] OFF: Report on Bell Cut-Off
BYP
Key [
] ON: Report on Zone Closure
BYP
[
] + Installer code + [0] [8] [8] + [
ENTER
Section #
Description of feature
1.2

New Features

Feature
2-wire smoke detector
Serial or parallel wiring for ATZ connections (see page 27)
Master Code Lock (see page 11)
New Pager reporting options: Pager Delay, Pager Format Options and
Pager Report Event Options (page 21)
Closing Delinquency Timer and Time options (see page 34)
Auto Test Report Time Option (see page 23)
Restrict Arming on Battery Failure (see page 34) and Restrict Arming on
Tamper Trouble (see page 34)
New on-board green
Timed Test Transmission (see page 24)
Bypassed zones reported to monitoring station on arming (see page 19)
1.3

Main Features

• 4 zone inputs (8 zones with ATZ) + 2 keypad zones (728 Ultra)
• 8 zone inputs (16 zones with ATZ) + 2 keypad zones (738 Ultra)
• 2 partitions
• 49 user codes
• 256 event buffer
• 1 PGM output for 728 Ultra and 2 PGM outputs for 738 Ultra (50mA transistor output)
• 1.1A switching power supply
• 1 supervised auxiliary output (728 Ultra: 450mA, fuseless shutdown at 650mA; 738 Ultra: 500mA, fuseless shutdown at 700mA)
• 1 supervised bell output (fuseless shutdown at 3A)
• 1 supervised telephone line (supports Ademco Contact ID, Pager and slow report formats)
• CTR-21 approved dialer
• On-board connectors for backup battery and serial port
• Compatible with all Esprit keypads
1.4

Specifications

• AC power:
• Battery:
• Aux. power:
• Bell output:
• PGM outputs:
• Serial data output:
† Please refer to Warnings on page 45 for UL Specifications. Specifications may change without prior notice.
Part 1: Introduction
Section title
Address 088; Key [
] key OFF, the report codes programmed at addresses 424 to 447 (see Restore Codes on page 22) will only
BYP
LED (see page 11)
STATUS
16.5Vac transformer with minimum 20VA rating (40VA recommended), 50-60Hz
12Vdc, 4Ah/7Ah†
450mA, fuseless shutdown at 650mA for 728 Ultra; 500mA, fuseless shutdown at 700mA for 738 Ultra)†
1A (fuseless shutdown at 3A)
One 50mA PGM transistor output (728 Ultra); Two 50mA PGM transistor output (738 Ultra)
(1200, 1, N) for use with accessory modules (not for use with UL systems)
Where the feature is
programmed
]
BYP
] ON/OFF + [
]
ENTER
How to program
728 Ultra
Factory default
Option
728 Ultra
738 Ultra
V4.10
V4.20 - 4.40
Esprit 728 Ultra & 738 Ultra
] key ON, the
BYP
738 Ultra V4.1
V4.0
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

738ult

Table of Contents