6.4

System Account Codes

Streamline - Section 08
All report codes are preceded by a 3- or 4-digit system account code to ensure correct identification to the monitoring station,
identifying from which security system the event originated. For example, if a zone opens, the control panel will first send the
account code followed by the appropriate report code. In a partitioned system, the control panel can send a separate account code
for each system. This will identify to the monitoring station from which partition the report code originated. To do so, program a
different number into each account code, where Account code #1 represents System A and Account code #2 represents System B.
If partitioning is disabled, program the same value for both account numbers.
There are no defaults and you can enter any hex digit from 0 to F. Please note, that if required, system account codes can have 3
digits. To do so, press the [2
[
] + Installer code + [7] + [0] [8] + 4-digit Account code #1 + 4-digit Account code #2 + [
ENTER
[
] + Installer code + [7] + [0] [8] + [2
ENTER
6.5

Communicator Formats

Streamline - Section 09
Default: Ademco Slow for both numbers
The following option will determine which format the control panel will use to communicate with the monitoring station. You can
select a different Communicator Format for each Monitoring Station Telephone Number. Using Table 6, select the appropriate
Communicator Format. The first digit represents the Communication Format for Monitoring Station Telephone Number 1
(MSTN1) and the second digit represents the Communication Format for Monitoring Station Telephone Number 2 (MSTN2).
Below you will find a brief description of all available Communicator Formats.
[
] + Installer code + [0] [3] [8] + First digit = (MSTN1) + Second digit = (MSTN2) + [
ENTER
Key
[2
] = ADEMCO slow (1400Hz, 1900Hz, 10bps)
ND
[1]
= (1400Hz, 1800Hz, 10bps)
[2]
= SILENT KNIGHT fast (1400Hz, 1900Hz, 20bps)
[3]
= SESCOA (2300Hz, 1800Hz, 20bps)
[4]
= RADIONICS (40Bps with 1400Hz handshake)
[5]
= RADIONICS (40Bps with 2300Hz handshake)
6.5.1

Ademco Contact ID (All Codes)

Please note that this format must use a 4-digit system account code (see section 6.4). Ademco Contact ID is a fast
communicator format that uses tone transmission instead of pulse transmission. This communicator format also uses a
pre-defined list of industry standard messages and event codes that should suit most of your basic installation needs.
Using the All Codes format, the control panel will automatically generate the Contact ID event codes (see Table 7) for
every event in addresses 300 to 527. Therefore, you do not need to program addresses 300 to 527.
Bypassed zones can automatically be reported to the monitoring station upon arming (738 Ultra only). If the first and
second digits of Address 038 (Communicator Formats 1 & 2) are both programmed with [0], the next time the system
is armed, the control panel will report to the monitoring station which zone(s) are bypassed.
System Event
Alarms/Restores
Alarm/Restore on Zone 3 if 24Hr fire or 2-wire
Alarm/Restore on Zone 5 if 2-wire enabled † (728 Ultra only)
Arm/Disarm
Zone Shutdown
Zone Tamper
Zone Tamper Reset
Auxiliary Power Trouble
Bell Disconnect/Max. Current Trouble
Low Battery
AC Fail
Fire Loop Trouble
If 2-wire smoke with ATZ
Hex Programming - Addresses 032 to 035
] key followed by the 3-digit account number.
ND
] + 3-digit Account code #1 + [2
ND
Hex Programming - Address 038
Table 6: Communicator Formats
Table 7: Contact ID Event Codes
Event Code Addresses Contact ID Message
301 to 349 / 351 to 399
] 3-digit Account code #2 + [
ND
Key
[6]
= RADIONICS with PARITY (1400Hz, 40Bps)
[7]
= RADIONICS with PARITY (2300Hz, 40Bps)
[8]
= * ADEMCO express
[9]
= * ADEMCO contact ID (programmable codes)
[0]
= * ADEMCO contact ID (all codes)
[
]/[
] = * PAGER FORMAT - (personal dialing)
TBL
TRBL
* = 4-digit account codes only
400 to 447
Burglary Zone #
402, 426
Fire Alarm
404, 428
Fire Alarm
Open/Close By User #
448 to 471
Burglary Bypass #
472 to 495
Sensor Tamper
510
Sensor Tamper
496 and 504
System Trouble
497 and 505
Bell 1 Trouble
498 and 506
Low System Battery
499 and 507
AC Loss
500 and 508
Fire Loop Trouble
]
ENTER
]
ENTER
]
ENTER
Contact ID Code #
130
110
110
401
573
383
383
300
321
302
301
373
Esprit 728 Ultra & 738 Ultra
19