Service and maintenance
5.3 FB error messages
Byte
Description
0
1
2
Cxh
80h
92h
A type other than BYTE has been specified in an ANY reference.
Cxh
80h
93h
The area identifier contained in the configuration (SDB1, SDB2x) of the logical address is not
permitted for these SFCs. Permitted:
Cxh
80h
A0h
Negative acknowledgment when reading from module; Ident profile fetches acknowledgment although
no acknowledgment is ready
A user who is not using the Ident profile wants to fetch DS 101 (or DS 102 to DS 104) although no
acknowledgment is available.
Cxh
80h
A1h
Negative acknowledgment when writing to the module; Ident profile sends command although a
communications module cannot receive a command
Cxh
80h
A2h
DP protocol error in layer 2 could be a hardware defect
Cxh
80h
A3h
DP protocol error in Direct-Data-Link-Mapper or User-Interface/User could be a hardware defect
Cxh
80h
B0h
Cxh
80h
B1h
The length specified in the RECORD parameter is wrong.
Cxh
80h
B2h
The configured slot is not occupied.
Cxh
80h
B3h
Actual module type is not the module type specified in SDB1
Cxh
80h
C0h
Cxh
80h
C1h
The data of the preceding write job on the module for the same data record have not yet been
processed by the module.
Cxh
80h
C2h
The module is currently processing the maximum possible number of jobs for a CPU.
Cxh
80h
C3h
Required resources (memory, etc.) are currently in use.
This error is not reported by the Ident profile. If this error occurs, the Ident profile waits until the
system is able to provide resources again.
Cxh
80h
C4h
Communication Errors
Checksum error on module side
Cxh
80h
C5h
Distributed I/O not available.
Dxh
8xh
xxh
A Dx8xxxh error is identical to the corresponding Cx8xxxh error (see Cx8xxxh).
Byte 3 contains additional warning information.
60
0 = S7-400
1 = S7-300
2, 7 = DP modules and backplane bus
Perform an init_run to resynchronize communications module and application
SFC not possible for module type.
Data record unknown to module.
Data record number ≥ 241 is not allowed.
Data records 0 and 1 are not permitted for SFC 58 "WR_REC".
RDREC:
The module has the data record, but there is not yet any data to be read.
WRREC:
Communications module is not ready to receive new data
Wait until the cyclic counter has been incremented
Parity error
SW ready not set
Error in block length management
Checksum error on CPU side
Communications module RF120C with application blocks for S7-1200 and S7-1500