Table 4- 8
Hex value
4.3.2.4

SLG D10S

Table 4- 9
SLG D10S
Parameter
RF power
Transponder type
4.3.2.5

SLG D11S/D12S

Table 4- 10
SLG D11S/D12S
Parameter
Transponder type
Communications module RF120C with application blocks for S7-1200 and S7-1500
Operating Instructions, 07/2013, C79000-G8976-C328-01
Transmit / radiated power of the antennas
RF630R
transmit power
dBm / (mW)
0
18 / (63)
1
19 / (79)
...
...
4
22 / (158)
...
...
9
27 / (501)
A
27 / (501)
B (...F)
27 / (501)
Parameter value
0.50 - 10.00 W
ISO
I-Code (e.g.
MDS D139)
Parameter value
ISO
I-Code (e.g.
MDS D139)
4.3 Parameter assignment with the device configuration
RF620R
radiated power (internal antenna)
ETSI
dBm / (mW)
dBm / (mW)
ERP
EIRP
18 / (63)
20 / (100)
19 / (79)
21 / (126)
...
22 / (158)
24 / (251)
...
27 / (501)
29 / (794)
28 / (631)
30 / (1000)
29 / (794)
31 / (1259)
Default value
Description
1.00 W
Setting for the output power of the reader.
ISO
Selection of the transponders used.
Default value
Description
ISO
Selection of the transponders used.
Parameter assignment and configuration
FCC
CMIIT
dBm / (mW)
ERP
18 / (65)
19 / (79)
...
...
22 / (158)
...
...
27 / (501)
28 / (631)
29 / (794)
RF620R
transmit power
dBm / (mW)
18 / (63)
19 / (79)
...
22 / (158)
...
27 / (501)
27 / (501)
27 / (501)
27