Ident Instructions - Siemens SIMATIC RF120C Operating Instructions Manual

Rfid systems communications module with application blocks for s7-1200 and s7-1500
Hide thumbs Also See for SIMATIC RF120C:
Table of Contents

Advertisement

Parameter assignment and configuration

4.4 Ident instructions

4.4
Ident instructions
To be able to operate the RF120C with various Ident systems, the TIA Portal provides you
with a global library. This library contains various Ident instructions.
The following table lists all the Ident instructions and program elements of the library.
Table 4- 14
Overview of the Ident instructions
Position
Ident
Ident application
instructions
blocks
(global library)
Ident profile
30
Type
Symbolic name
Function block
Reset_Reader
Read
Write
Read_EPC-ID
Write_EPC-ID
Set_Ant
PLC data type
HW_CONNECT_VAR
Function block
AdvancedCmd
Function block
Ident profile
PLC data type
PIB_COMMAND
PLC tags
PIB constants
Communications module RF120C with application blocks for S7-1200 and S7-1500
Description
These Ident instructions are available
so that the communication with the
Ident systems can be programmed as
simply as possible.
Separate data type for all Ident
application blocks for physical
addressing of communications
modules and readers and for
synchronizing the function blocks used
for each reader.
Advanced command set. With the
Ident application block
"AdvancedCmd" it is possible to
access other commands from the Ident
command set.
One instruction, full flexibility. This
block is available for experts to be able
to include complex command
structures in their own program
sequence.
Data type for the Ident profile for
setting the command parameters.
Constants of the Ident profile
Operating Instructions, 07/2013, C79000-G8976-C328-01