Service and maintenance
5.3 FB error messages
Byte
Description
0
1
2
E6h
FEh
04h
E6h
FEh
05h
An error has occurred that makes a Reset_Reader (WRITE-CONFIG with Config = 3) necessary.
E6h
FEh
06h
The timer for "Reset_Reader" has elapsed
E7h
FEh
01h
In this state, only the "Reset_Reader" command is permitted.
E7h
FEh
02h
The CMD command code is not permissible.
E7h
FEh
03h
The length parameter of the command is too long.
It does not match the global data reserved in the send data buffer (TXBUF).
E7h
FEh
04h
Overflow of the receive data buffer (RXBUF)
More data was received than memory available in the RXBUF
E7h
FEh
05h
This error tells the user that only an INIT command is permissible as the next command. All other
commands are rejected.
E7h
FEh
06h
Wrong index (outside range of 101 to 108)
E7h
FEh
07h
Communications module does not respond to INIT (INIT_ACTIVE is expected in the cyclic status
message).
E7h
FEh
08h
Time exceeded during INIT
(60 seconds according to TC3WG9)
E7h
FEh
09h
Command repetition is not supported.
Fxh
FEh
xxh
An FxFExxh error is identical to the corresponding ExFExxh error (see ExFExxh).
Byte 3 contains additional warning information.
58
Presence error: A transponder has passed by a reader without being processed by a command.
This error message is not reported immediately. Instead, the communications module is waiting
for the next command (read, write). This command is immediately replied to with this error. This
means that a read or write command is not processed. The next command is executed normally
again by the communications module.
An init_run from the Ident profile also resets this error status.
Bit 2 is set in the OPT1 parameter and there is no transponder in the transmission window.
Error(s) in the WRITE-CONFIG command
Start init_run command after error correction
Check the HW_CONNECT parameter.