Table 2.5
Installation specifications of the PRIMEPOWER650 rack-mount type
(8U) server (2/3)
Item
Temperature Operating
(Note 4)
Not operating
Humidity
Operating
Not operating
Heat
4 CPU
dissipation
8 CPU
Vibration
Operating
Not operating
Noise level (Note 5)
Installation type
Note 3: In model names, x is any letter from A to Z. And y is any letter from A to Z
or any digit from 0 to 9.
Note 4: A warning message appears during operation if the ambient temperature
exceeds 35 °C (95°F). Take immediate corrective action.
Note 5: The indicated noise level is the mean value of noise measured when the
main unit is installed in an 1800-mm rack in a low-noise anechoic chamber.
The actual noise level measured at the installation site may be greater than
the indicated value because of background noise and echoes.
U41261-J-Z816-4-76
(Model name: PW0RCRyyyx,
PW0RDRyyyx, PW0RFRyyyx,
PW0RGRyyyx) (Note 3)
5 - 35 °C ( +41 ~ +95 °F)
[When installed at height of 0 to 1500 m (0 to 4921.2 ft) above sea
level]
5 - 33 °C ( +41 ~ +91.4 °F)
[When installed at height of 1500 to 2000 m (4921.2 to 6561.6 ft) above
sea level]
5 - 32 °C ( +41 ~ +89.6 °F)
[When installed at height of 2000 to 2500 m (6561.6 to 8202 ft) above
sea level]
5 - 30 °C ( +41 ~ +86 °F)
[When installed at height of 2500 to 3000 m (8202 to 9842.4 ft) above
sea level]
0 - 50 °C ( +32 ~ +122 °F)
20 ~ 80 % RH (Non-Condensing)
8 ~ 80 % RH (Non-Condensing)
5,580 kJ/hr (5,228 BTU/hr)
7,380 kJ/hr (6,995 BTU/hr)
0.2 G
0.4 G
58 dBA
Rack-mount (8 pitch)
2.3 Preparing for Operation
Specifications
(Model name: PW0R0CR1x,
PW0R0CR6x, PW0R0DR1x,
PW0R0DR6x, PW0R0AR2x,
PW0R0AR7x)
4,212 kJ/hr (3,992 BTU/hr)
5,832 kJ/hr (5,528 BTU/hr)
50 dBA
23