COLLEGAMENTO ELETTRICO

18
Controllare che la tensione dell'impianto elettrico corrisponda a quella
indicata sulla targhetta caratteristiche posta sul lato sinistro in basso nella
parte interna dello scomparto congelatore.
Se la presa a muro è priva di contatto a terra, o se la spina non è adatta al vo-
stro impianto vi consigliamo di rivolgervi ad un elettricista specializzato.
Non impiegare adattatori o derivatori che potrebbero causare riscaldamenti
e bruciature.

ELECTRICAL CONNECTION

Check that the main voltage corresponds to that indicated on the rating plate
in the lower left side inside the freezer compartment.
If the wall socket does not have an earth terminal, or if the plug does not fi t
into the socket, it is advisable to consult a qualifi ed electrician. Do not use
multiple plugs or adapters as they could cause heating and burning.
WARNING: THIS APPLIANCE MUST BE EARTHED
If this appliance is fi tted with a non rewirable plug for which your socket is unsuitable,
the plug should be cut off and an appropriate plug fi tted. The removed plug must be
disposed of Insertion of the plug into a 13 Amp socket is likely to cause an electrical
hazard When a nonrewirable plug ora rewirable 13 Amp (BS1363) plug is used it must
be fi tted with a 13 Amp ASTA approved (BS1362) fuse. If any other type of plug is used
it must be protected by a 15 Amp fuse either in the plug or at the distribution board
13 amp
Fuse
Brown
to Live
Cord
Clamp
IMPORTANT: THE WIRES IN THE MAIN LEADS ARE COLOURED IN AC-
CORDANCE WITH THE FOLLOWING CODE:
GREEN AND YELLOW - EARTH BLUE - NEUTRAL - BROWN - LIVE
As the colours of the wires in the main lead of your appliance may not cor-
respond with the coloured marking identifying the terminals in your plug,
proceed as follows.
CONNECT GREEN & YELLOW coloured wire to plug terminal marked letter
"E" or earth symbol
or coloured green or green & yellow.
CONNECT BLUE coloured wire to plug terminal marked letter "N" or coloured black.
CONNECT BROWN coloured wire to plug terminal marked letter "L" or
coloured red.