Accessories; Locating The Boiler; Installing Elastomer Cube Isolation Mounts - FULTON PulseHW Series Installation, Operation And Maintenance Manual

Gas pulse combustion hydronic heating boilers
Table of Contents

Advertisement

5. Other Accessories
a) Condensate Drain - one condensate drain kit can
accommodate the condensate from up to eight (8)
Pulse boilers.
b) Spring Mounts - standard spring isolators as well as
seismic spring isolators are available from the
factory. The springs are an alternative to the
elastomer coated fiberglass cubes.
c) Mufflers

6. Locating the Boiler

a) Be sure to familiarize yourself with and consider all connections on the boiler before
starting the installation procedure. Include air supply and exhaust piping (as per
requirements specified on page 33 of this manual), water piping, gas piping, placement of
elastomer cubes/springs, condensate drain, and electrical connections in your review.
Verify that all minimum clearances as per factory requirements in Figure 1 below are
observed, as well as any local codes that pertain to the geographic location where the
boiler is being installed.
Figure 1
The Fulton Pulse Hot Water (PHW) Series boiler is designed for use in closed loop
heating systems. It is not designed for use in systems where water is replenished.
Mineral build up can occur on the heat transfer surfaces and result in equipment
failure.

7. Installing Elastomer Cube Isolation Mounts

a) All pulse combustion boilers must be installed with vibration isolators. No pulse
combustion boiler shall be lagged directly to the concrete floor due to the transfer of
vibration. In the box of trim shipped with each Pulse boiler, Fulton supplies 4 elastomer
cubes used for vibration isolation. For all non-critical installations these 3" x 3" x 2"
cubes must be under each foot of the boiler. Flex connectors must be installed on the gas
Fulton Heating Solutions, Inc. -- PHW Manual -- 2010-0713
Note
(Figure 2a)
Page 21