Call
diagnostics
Read
diagnostics
.
.
.
Fig. 3-8
Request and read diagnostics
Important
For the slave IM 328–N the following diagnostics are of considerable
diagnostics for
importance:
IM 328–N, slave
Structure and
The diagnostics are loaded and transferred with the following instructions:
requesting
L KY (station number), (code)
diagnostics
T PW 252
Eight words in each slave station are reserved for station status, device–
oriented (station diagnostics) and ID–oriented diagnostics (module
diagnostics).
Siemens AG 1996 All Rights Reserved
SINUMERIK 805SM / 840C (BS)
Diagnostics word
Station status
Device–oriented diagnostics (station diagnostics)
Code
Diagnostics address
0
Station status 1
1
Station status 3
2
3
Header
4
Header
5
Unused
6
Unused
7
Unused
6ZB5 430–0BH02–1AA0
3.2 Description of the DP standard slaves
Diagnostics data
Station number 3 to 124
Code: 0 to 7
After that, the station diagnostics are
transferred to the diagnostics word
Diagnostics address + 1
Station status 2
Master address
Manufacturer ID
Device–oriented diagnostics
(station diagnostics)
ID–oriented diagnostics
(module diagnostics)
Unused
Unused
Unused
Description