Siemens IM 328–N Description page 15

Sinumerik 805sm/840c link to sinec l2–dp
Table of Contents

Advertisement

07.96
Note
The switches not required for the 8, 16 and 32-byte address ranges are irrele-
vant and any setting is permissible.
Switch S2.1 = OFF and S2.2 = OFF
Base address for
4–byte address range
Base address
Base address for
Switch S2.1 = OFF and S2.2 = ON
8–byte address range
Base address
x: Switch position of no significance
Siemens AG 1996 All Rights Reserved
SINUMERIK 805SM / 840C (BS)
2.1 Hardware of the module 6FC5 012–0CA03–0AA0
S3.8
S3.7
0
ON
ON
4
ON
ON
8
ON
ON
12
ON
ON
16
ON
ON
:
:
:
1020
OFF
OFF
9
8
Significance
2
2
=512
=256
S3.8
S3.7
0
ON
ON
8
ON
ON
16
ON
ON
24
ON
ON
32
ON
ON
:
:
:
1016
OFF
OFF
9
8
Significance
2
2
=512
=256
6ZB5 430–0BH02–1AA0
S3.6
S3.5
S3.4
S3.3
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
:
:
:
:
OFF
OFF
OFF
OFF
7
6
5
4
2
2
2
2
=128
=64
=32
=16
S3.6
S3.5
S3.4
S3.3
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
:
:
:
:
OFF
OFF
OFF
OFF
7
6
5
4
2
2
2
2
=128
=64
=32
=16
Description
S3.2
S3.1
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
:
:
OFF
OFF
3
2
2
2
=8
=4
S3.2
S3.1
ON
x
OFF
x
ON
x
OFF
x
ON
x
:
OFF
x
3
2
=8
2-3
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Im 329–n

Table of Contents