Culligan Premier Series Installation, Operation And Service Instructions page 47

Automatic deionizer water treatment systems models from 2012
Table of Contents

Advertisement

Check Inputs
The Check Inputs diagnostic displays the status of the switch(es) based on water quality. If the water quality meets the
minimum requirements then SW1 (and SW2 if duplex alternating) will be open and water will flow through the system. If
the water quality does not meet the minimum requirements then SW1 (and SW2) will be closed and water will not flow
through the system.
SERVICE
FEB-01-13 12:11P
10.0GPM 161PPM
3)SET DATE/TIME
4)ADV. SETUP
5)ACCESSORIES
>6)DIAGNOSTICS
1)MANUAL CONTROL
>2)CHECK INPUTS
3)TEST PHONELIN
4)TEST PROGFLOW
CHECK INPUTS
SW1: OP
FLOW METER
6
PULS/SEC
SERVICE
FEB-01-13 12:11P
10.0GPM 161PPM
Cat. No. 01024000
1.
From the default home screen, press
2.
Press
tion and settings.
3.
Press
to select 2) CHECK INPUTS.
4.
The screen displays the open or closed state of auxiliary switch SW1 (and SW2
if a duplex alternating system). OP means that water quality meets the minimum
requirements so the switch is open. CL indicates water quality that does not meet
the minimum requirements—the switch is closed. Press any key to view the next
diagnostic screen.
5.
If a flow meter is installed, the screen displays the flow meter pulse count (pulses
per second). Press any key to return to the home screen.
6.
The controller automatically returns to the home screen after a few moments.
to display the main menu.
to select 6) DIAGNOSTICS, the diagnostics informa-