Cat. No. 01022940
Rev. E 02/14/14
DCO # 014260
Installation,
Operation and
Service
Instructions
CULLIGAN
®
M1 Series
Reverse Osmosis Water Treatment
Systems
Models from 2011
©2014 Culligan International Com pa ny

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M1 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Culligan M1 Series

  • Page 1 Cat. No. 01022940 Rev. E 02/14/14 DCO # 014260 Installation, Operation and Service Instructions CULLIGAN ® M1 Series Reverse Osmosis Water Treatment Systems Models from 2011 ©2014 Culligan International Com pa ny...
  • Page 2 We encourage Culligan users to learn about Culligan products, but we believe that product knowledge is best obtained by consulting with your Culligan dealer. Untrained individuals who use this manual assume the risk of any resulting property damage or personal injury.
  • Page 3: Table Of Contents

    Reverse Osmosis Water Treatment Systems Using the CP Plus Controller Models From 2011 Contents Introduction ................ Features ................M1 Series Specifications ........... Unit Configurations ............M1 RO Installation ............. Operation ................. Initial Startup..............Accessories ..............Service and Maintenance ..........Flow Diagram ..............
  • Page 4 (psi) 0.0689 degrees Fahrenheit (F) degrees Centigrade (C ) (F-32) x 0.556 pounds (lbs) kilograms (kg) 0.4536 Inches (in) millimeters (mm) 25.4 parts per million (ppm) mg/l 1.00 Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 5: Introduction

    ® device and its capabilities. Culligan M1 Series reverse osmosis systems are designed to meet the needs of applications for high quality water. This ® manual contains important information about the unit, including information needed for installation, operating, and mainte- nance procedures.
  • Page 6: Features

    M1 Series Reverse Osmosis systems are the direct result of Culligan’s long-time experience in membrane ® applications around the world. From process water for any size business to treating water for an entire city, Culligan has the knowledge and the range of products you need to get the job done.
  • Page 7: M1 Series Specifications

    M1 Series Specifications NOTE Specifications for M1 RO 230V (international) are in “M1 RO International Specifications” on page Nominal Capacity, GPD [m³/hr]* 1000 1200 1700 2200 2000 4000 [0.04] [0.08] [0.12] [0.16] [0.19] [0.27] [0.35] [0.32] [0.63] Dimensional, Series M1 Units Width - in [mm] 34.5 [876]...
  • Page 8: Unit Configurations

    Membranes Recirculation Control Power ON/OFF RUN NOW Waste Switch Button Control Prefilter Figure 1. M1 RO front view. Mounting Brackets Pump Motor Pressure Switch Inlet Solenoid Figure 2. M1 RO back view. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 9: M1 Ro Installation

    M1 RO Installation Unpacking the M1 RO This manual, the warranty, and registration card are packed in the control assembly box. Please complete the registration card and mail it promptly. NOTICE Examine each unit component carefully to check for loose or damaged parts. Report any apparent or concealed shipping damage to the freight carrier immediately.
  • Page 10 Drill the holes in the wall and mount the unit. Horizontal holes are on 16" centers. Verti- cal holes are on 2" centers. Figure 3. RO wall assembly bracket kit (included with unit). Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 11 Wall Mounting Kit (optional) If the wall is not concrete and wall mounting is necessary, a wall mounting bracket kit is available. The bracket has holes for mounting on 18” and 20”centers. Use bracket P/N 01023017 for all models. Place the bracket adapter on the wall with the flat side towards the wall. Level the bracket adapter and mark the wall through the appropriate holes.
  • Page 12 Remove the paper wrapper from the cartridge, place the cartridge in the bowl, and screw the bowl onto the head. Pressure Inlet Relief Button Outlet Filter Cartridge Figure 7. Installing the Prefilter. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 13 Membranes Before mounting the membrane housings, the membranes must be inserted into the housings. Take care to not damage the end cap O-rings or membrane brine seal. The membranes are shipped in a sealed package. Use extreme caution when opening the package with a sharp instru- ment.
  • Page 14 To Membrane Feed (1/2" Tube) Pressure Gauge Tube From Membrane Product Tube (1/2" Tube) Return Assembly Tube From Membrane Concentrate (3/8" Tube) System Inlet (1/2" Tube) Figure 9. M1 Series tubing configuration. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 15 Plumbing Installation Refer to the tubing assembly instructions in Figure 10 on page 12 through Figure 15 on page 17 and the hydraulic schematic/flow diagram on page 42 for further information. Feed Water Connections Connect tubing to the Feed water inlet. Observe the following: To minimize pressure loss, the tubing size should be at least 1/2”.
  • Page 16 INSERT 1/2"X3/8" ELBOW OVER 3/8" STEM REMOVE CAPS ON 3/8" STEMS REMOVE CAPS ON 3/8" STEMS 3/8" TUBE FOR RECIRCULATION/WASTE INSERT 3/8" FITTING ASSEMBLY OVER 3/8" STEM Figure 10. RO 1S tubing assembly instructions. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 17 2S/2L Tubing Assembly Instructions 1/2" TUBE FOR FEED INSERT 1/2"X3/8" ELBOW USED FOR FLOOR OVER 3/8" STEM STAND APPLICATION 3/8" TUBE FOR RECIRCULATION/WASTE 1/2" TUBE FOR PRODUCT INSERT 3/8"X3/8" ELBOW OVER 3/8" STEM REMOVE CAPS ON 3/8" STEMS INSERT PRODUCT FITTING ASSEMBLY OVER 3/8"...
  • Page 18 3S/3L Tubing Assembly Instructions Figure 12. RO 3S/3L tubing assembly instructions. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 19 4S/4L Tubing Assembly Instructions Figure 13. RO 4S/4L tubing assembly instructions. Cat. No. 01022940 M1 RO Installation...
  • Page 20 ON 1/2" STEMS ASSEMBLY ON MOTOR PANEL M1/G1-1F UNITS ONLY USED ONLY IN INSERT FITTING ASSEMBLY M1/G1-1F UNITS OVER 1/2" STEM 3/8" TUBE FOR RECIRCULATION/WASTE Figure 14. RO 1F tubing assembly instructions. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 21 2F Tubing Assembly Instructions USED FOR FLOOR STAND APPLICATION 1/2" TUBE FOR PRODUCT 1/2" TUBE FOR FEED INSERT 1/2"X1/2" ELBOW OVER 1/2" STEM 3/8" TUBE FOR RECIRCULATION/WASTE INSERT 3/8"X1/2" ELBOW OVER 1/2" STEM INSERT PRODUCT FITTING ASSEMBLY OVER 1/2" STEMS REMOVE CAPS ON 1/2"...
  • Page 22 Valve SV4 closes when the RO pump runs; SV4 opens when the pump stops, allowing all membrane back proessure to be relieved. NOTICE Product back pressure will decrease the net pressure pushing water through the reverse osmosis elements. Therefore, the flow of product water will decrease. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 23 Electrical Installation WARNING! The system must be grounded. Do not remove grounding prong! An improperly grounded unit could cause injury from electrical shock! CAUTION! Observe the cautions listed below before the electrical installation of the controller. Failure to do so might cause permanent damage to the RO controller. CAUTION! Before performing any electrical wiring refer to the electrical schematics.
  • Page 24 Dry Contact Connections The dry contact terminal strip is located on the bottom right of the circuit board (see Figure 18). Do not apply any voltage to these terminals. Use dry contacts only. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 25: Operation

    OPEN Figure 19. CP Plus controller front panel. The CP Plus controller monitors the Culligan E1 Plus, M1, and E2 Plus commercial RO product lines. The controller re- quires no programming and has the following capabilities: • Control for 115 VAC or 230 VAC single-phase motor (refer to...
  • Page 26: Initial Startup

    Depending on the feed water quality, it may be possible to operate the unit with a lower concen- trate flow rate, which would decrease operating costs. Refer to the printout from the Culligan® CAAP® (Computer Aided Application Program) software, which indicates maximum allowable recovery.
  • Page 27 Once all the desired flows are set, allow the system to run for approximately 30 minutes, and then record the following measurements using the units gauges (U) and your instruments (I): a. Feed Water Temperature, °F (I) b. Feed Water SDI (I) c.
  • Page 28 DIP switch settings are not designed to perform accurately when multiple DIP switches are in the ON position. Setting more than one switch to the ON position will result in a reading less than either switch setting. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 29 100 gpd, or 18% (100/570) = 0.18. The elements should be cleaned. 10. If the problem cannot be corrected with the troubleshooting guide and assistance is required, please have the following information available when calling the Culligan dealer: • Product flow rate •...
  • Page 30 Smart (GBE) Controller SW6 Dip Switch Battery Motor Comm CP Plus Controller P9 Power 2.5VAC 24V Aux1 Aux2 P7 Sol Flow Aqua Valve Sensor Meter Relay Figure 20. MVP to CP Plus relays. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 31 Wiring for Hi-Flo® 22, Hi-Flo® 55e, CSM Softeners and Filters with GBE Controls For these systems, you must add a 24 VAC relay, part number 01016156, to provide the pretreatment contact. GBE to Relay: Connect a wire from terminal 5 of the relay to the left terminal of Aux 4 on the GBE softener/filter circuit board.
  • Page 32 When using pressurized storage, you must use a pressure switch that provides a closed signal when the tank is below the specified shut off pressure, such as the switch provided in the Pressurized Water Storage Kit. CAUTION! Do not apply power to these terminals. Use dry contacts only. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 33: Accessories

    Accessories TDS Probe (Optional: Order Separately) An optional TDS probe (P/N 01021876) monitors the water quality in the system. If the total dissolved solids measured by the TDS probe exceeds the required quality level set by the DIP switches, the system will stop producing treated water. The probe is connected to the CP Plus board via an MT board (P/N 01022143): see Figure 23.
  • Page 34: Service And Maintenance

    Service and Maintenance Serial Numbers The Culligan M1 units have a serial number located directly behind the electronic controller on the side panel. Do not remove or destroy these serial number labels. They must be referenced if you require repairs or parts replacement under warranty.
  • Page 35 Unit running but poor quality A. Low pump pressure. A. See 2. (less than 95% rejection) B. Module failure. B. Replace modules. Check product line over pressurization. C. Concentrate throttling valve C. Throttle valve down. open. D. Poor seal on endcap or D.
  • Page 36 Refer to the section on Initial Startup for information on flushing the shipping solution form the new elements. NOTE Do not forget to enter the new values for flow, pressure, temperature, and TDS. NOTICE The RO elements (membranes) require a 24 hour pre-service flush. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 37 Screws Retaining Rings End Cap O-Rings Housing Membrane Brine Seal Figure 24. M Series membrane. Cat. No. 01022940 Service and Maintenance...
  • Page 38 NOTICE Some replacement motors may be prewired for 230 Volt operation at shipment. Refer to wiring schematic on the motor label and verify that the motor is wired for 110 Volt operation. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 39 Sanitizing Modules The modules may need sanitizing if either of the following conditions exist: • The RO system is subject to biofouling and the operator wants to reduce the cleaning frequency. • The water treatment application limits the microbial count in the product water. CAUTION! The bottom of the tank must be higher than the pump on the RO unit to prevent cavita- tion of the pump when solution is drawn from the tank.
  • Page 40 Apply power to the unit, and then press the RUN NOW button. Slowly close the recirculation and drain valves until the system operating pressure increases to normal pressure. NOTE Increase the pressure no faster than 5 psi per second. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 41 Allow the unit to run for at least 30 minutes. Check the product water until the pH for the concentrate and prod- uct remains stable for five (5) minutes and the TDS is greater than 95 percent rejection. Turn the unit power off. Connect the concentrate tubing from the membrane to the motor panel.
  • Page 42 Tank stand, to elevate solution tank to level above pump. Tubing 1/2” O.D. to connect cleaning adapter ahead of Pre-filter. A pH meter. A pre-filter cartridge (P/N 00955004). Before proceeding record the “NOW” values in Table Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 43 Prepare the Equipment for Cleaning Turn the unit power off. Place the solution tank on the tank stand. Connect the tubing to the cleaning adapter then place the other end of the tubing at the bottom of the solution tank. NOTICE The tubing length should be as short as possible to prevent excessive pressure drop.
  • Page 44 The temperature of the chemical solution will rise as it is recirculated. If the temper- ature exceeds 95°F, turn the unit power off and allow the solution to cool to prevent damage to the RO elements. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 45 Compare these values with the “new” and “now” values to determine if cleaning has been successful. If cleaning has not been successful, contact the service department at Culligan International Company for suggestions on alternate cleaning chemicals. If cleaning has been successful, note which chemicals were effective. Use the same chemical(s) when the unit is cleaned again.
  • Page 46: Flow Diagram

    Flow Diagram Reverse Osmosis Process Flow Diagram Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 47: Wiring Diagram

    Wiring Diagram Series M1 Wiring Diagram GREEN GREEN PRESSURIZED 115V/60Hz/1PH STORAGE KIT WHITE INCOMING POWER D1013880 BLACK WHITE BLACK POWER CORD, MOTOR WHITE BLACK CABLE, SOLENOID PRETREATMENT LOCKOUT SWITCH A NORMALLY CLOSED switch is required. This A NORMALLY CLOSED switch is OPEN during regeneration, but is Level Switch is required.
  • Page 48: M1 Ro Parts Diagrams And Lists

    To Membrane Feed (1/2" Tube) Pressure Gauge Tube From Membrane Product Tube (1/2" Tube) From Membrane Return Assembly Tube Concentrate (3/8" Tube) System Inlet (1/2" Tube) Figure 27. M1 RO rear view. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 49 M1 RO Series Item Part No. Description Qty Qty Qty Qty Qty Qty Qty Qty Qty 01024485 Motor Panel Assembly, M1-1S, M1- 2S, M1-3S, M1-4S 01024504 Motor Panel Assembly, M1-2L, M1-3L 01024505 Motor Panel Assembly, M1-4L 01024506 Motor Panel Assembly, M1-1F, M1-2F 01021992 Assembly, Feed 01021993...
  • Page 50 Solenoid Assy, 120V/60Hz with bullet connectors 01023070 Solenoid Coil, Repl, 110-120V/50–60Hz 01007604 Pressure Gauge, 1/4" NPT, 0–200 PSI, Liquid filled — Tee, 1/2" Socket, PVC Sch. 80 — Plug, 1/2", Spig 01024477 Cable, Solenoid, E1/M1/G1 Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 51 Return/Recycle Assembly and Pressure Transducer To Pump Inlet Figure 29. Return/Recycle assembly with pressure transducer. Item Part No. Description Quantity 01021993 Assembly, Return (items 1–11) — 1/2" Sch.80 Pipe, 3.5" length — Tee, 1/2” Socket, PVC Sch.80 — Tee, 1/2", Threaded, PVC Sch.80 —...
  • Page 52 — Tee,3/8",Socket,PVC Sch.80 — Bushing,3/8x1/4,SxT,PVC Sch.80 — Pipe, 3/8", SCH 80, Length 1.75" — Bushing,3/8x1/4,SxS,PVC Sch.80 — Connector,Male,1/4 NPTx3/8 Tube,PI,PP — Nipple,1/4x1-3/4,PVC Sch.80,TOE — Plug, 3/8" Cap, Socket — Stem Adapter,1/4Tx3/8 Stem,PP Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 53 System Pressure Gauge Assembly Figure 31. Pressure Gauge Assmbly. Item Part No. Description Quantity 01021997 System Pressure Gauge Asembly — Bushing, 1/2"x1/4", TxT, PVC Sch. 80 — Tee, 1/2”, Threaded, PVC Sch. 80 — 1/2”-1/2” NPT Tube, Male Connector 01007604 Pressure Gauge Cat.
  • Page 54 The amount listed for the units refers to the number of individual o-rings required NOT the number of packets required for an entire unit; i.e. an entire M1-2S unit requires 4 individual o-rings NOT 4 packages of o-rings. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 55 1S Sub-Assembly FEED Top View PRODUCT Note Direction of Flow A = to Feed Port B = to Recirculating Assy Bottom View C = to Center Port (Product) Figure 33. M1-1S sub-assembly. Item Part No. Description Quantity 01023412 Assembly, Membrane, Single, 2.5"x21" 01023904 Kit, Tube and Fittings, 1S (includes items 1–5) —...
  • Page 56 Elbow, Union, Reducing, 1/2 x 3/8, PI, Polypropylene 2 EA — Tee, Union, Reducing, 1/2 Ends, 3/8 Branch, PI, 1 EA Polypropylene — Elbow,1/2 Stem x 1/2T,PI 1 EA — Plug, 1/4" NPT, PVC Sch 80 2 EA Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 57 3S/3L Sub-Assembly Top View Used Only When Mounting on Floor FEED Stand PRODUCT Note orientation of flow A = to Feed Port B = to Recirculating Assy C = to Center Port (Product) Bottom View Figure 35. M1-3S/3L sub-assembly. Item Part No. Description Item Part No.
  • Page 58 Elbow, Union, 3/8 Tube, PI, 7 EA Polypropylene — Plug, 1/4” NPT, PVC, Sch 80 4 EA — Tube, 3/8", cut length 4.4" 3 EA — Tube, 1/2", Length 4.25" 3 EA Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 59 1F Sub-Assembly FEED PRODUCT Note Direction of Flow A = to Feed Port Top View B = to Recirculating Assy C = to Center Port (Product) Bottom View Figure 37. M1-1F sub-assembly. Item Part No. Description Quantity 01022875 Assembly, Membrane Housing, Single, 4.0"x40" 01023922 Kit, Tube and Fittings, 1F (includes items 1–7) —...
  • Page 60 Plug, 1/2" NPT, PVC Sch 80 2 EA — BUSHING,3/4x1/2,TxT,PVC SCH.80, 4 EA — Tee, Union, 1/2 Tube, PI, Polypropylene 1 EA — Elbow,1/2 Stem x 1/2T,PI 1 EA — Tube, 1/2", Length 7.5" 2 EA Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 61 CP Plus Controller Assembly Figure 39. CP Plus Controller assembly. Item Part No. Description Quantity — 01024478 Controller, CP Plus, complete 01025746 Assembly, Cable, Rocker Switch 01024282 Assembly, Cable, Push Button 01024139 Circuit Board, CP Plus Controller 01024179 Power Cord, CP Plus Controller Cat.
  • Page 62: Appendix A M1 Ro International

    FV-1 Flame Rating. Type H05VV-F/H07RN-F or equivalent, 3x1.5 mm wire size, 10.5x12.5 cable OD. The supply cord shall have a green/yellow core that is connected to the grounding terminal of the appli- ance and to the grounding contact of the plug. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 63 CP Plus Circuit Board 230V WARNING! The 115/230V Voltage Selector Switch must be set at 230V. Setting the CP Plus board to incorrect voltage will cause permanent damage to equipment. Fuse: 250 VAC 125 mA, 115V/230V Voltage 5mm x 20mm Selector Switch GREEN/YELLOW BLUE...
  • Page 64 *Nominal capacity based on new RO membranes operating on a properly pretreated feed water of 500 ppm TDS as NaCl, 77 °F (25 °C), Silt Density Index (SDI) below 3, and supplying water to atmosphere. Productivity will vary depending on the actual feed water quality and temperature. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 65 1S Tubing Assembly Instructions, 230V 10mm TUBE FOR FEED INSERT 10mm ELBOW USED FOR FLOOR OVER 10mm STEM STAND APPLICATION 10mm TUBE FOR RECIRCULATION/WASTE 10mm TUBE FOR PRODUCT INSERT 10mm ELBOW OVER 10mm STEM INSERT PRODUCT FITTING ASSEMBLY OVER 10mm STEMS REMOVE CAPS ON 10mm STEMS NOTE DIRECTION OF FLOW...
  • Page 66 REMOVE CAPS ON 10mm STEMS NOTE DIRECTION OF FLOW REMOVE CAPS ON 10mm STEMS INSERT FEED FITTING ASSEMBLY OVER 10mm STEMS (BOTTOM SIDE OF MEMBRANES) Figure 43. RO 2S/2L tubing assembly instructions, 230V. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 67 3S/3L Tubing Assembly Instructions, 230V Figure 44. RO 3S/3L tubing assembly instructions, 230V. Cat. No. 01022940 M1 RO International...
  • Page 68 REMOVE CAPS ON 10mm STEMS NOTE DIRECTION OF FLOW REMOVE CAPS ON 10mm STEMS INSERT FEED FITTING ASSEMBLIES OVER 3/8" STEMS (BOTTOM SIDE OF MEMBRANES) Figure 45. RO 4S/4L tubing assembly instructions, 230V. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 69 M1 RO International Parts Figure 46. M1 RO front view. System To Membrane System Waste Tube Feed Tube Product Tube Concentrate from Membrane Assy Product from Membrane Assy System Inlet Tube Figure 47. M1 RO rear view. Cat. No. 01022940 M1 RO International...
  • Page 70 CP Plus board to incorrect voltage will cause permanent damage to equipment. WARNING! Motors must be wired to the appropriate voltage and Hz. Connecting to incorrect voltage will cause permanent damage to equipment. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 71 M1 RO International Feed Assembly Figure 48. Feed Assembly. Item Part No. Description Quantity 01024238 Assembly, Feed, 220V, M1 (items 1–8) — Tee, 1/2", Threaded, PVC Sch. 80 — Male Adapter, 1/2" Spigot x NPT, Sch. 80 — Elbow, 1/2" Soc, PVC Sch. 80 —...
  • Page 72 — Elbow, Union, 10mm 3 EA — Elbow, Stem, 10mm 1 EA — Stem Adapter, 1/4 BSPP, 10mm 3 EA — Connector, 1/4 BSPP, 10mm 1 EA — Plug, 10mm 1 EA Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 73 2S/2L Sub-Assembly, 230V Used Only When Mounting on Floor Stand FEED PRODUCT Note orientation of flow Top View A = to Feed Port B = to Recirculating Assy C = to Center Port (Product) Bottom View Figure 50. 2S/2L sub-assembly, 230V. Item Part No.
  • Page 74 (includes items 1–9) 3S, 3L — Elbow, Union, 10mm 7 EA — Tube, 10mm 2 EA — Tube, 10mm 2 EA — Stem Adapter, 1/4BSPP, 10mm 9 EA — Connector, 1/4BSPP, 10mm 3 EA Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 75 4L Sub-Assembly, 230V Top View Used Only When Mounting on Floor Stand FEED PRODUCT Note Orientation of Flow A = to Feed Port B = to Recirculating Assy C = to Center Port (Product) Bottom View Figure 52. 4L sub-assembly, 230V. Item Part No.
  • Page 76 The amount listed for the units refers to the number of individual o-rings required NOT the number of packets required for an entire unit; i.e. an entire M1-2S unit requires 4 individual o-rings NOT 4 packages of o-rings. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 77 CP Plus Controller Assembly, 230V Figure 54. CP Plus Controller assembly. Item Part No. Description Quantity — 01024558 Controller, CP Plus, 220V, complete 01025746 Assembly, Cable, Rocker Switch 01024282 Assembly, Cable, Push Button 01024139 Circuit Board, CP Plus Controller Cat. No. 01022940 M1 RO International...
  • Page 78 Part No. Description Quantity — 01021987 Floor Stand Assembly, 1 Series RO — Stand, Side Rail Assembly 2 EA — Trim, Edge, Length 17" 1 EA — Bracket, Membrane Hanger Mount 1 EA Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 79: Appendix B Basic Principles

    Appendix B Basic Principles Reverse Osmosis In order to understand reverse osmosis, we must first define osmosis. Osmosis is the passage of a liquid through a semi-permeable membrane. A semi-permeable membrane is a membrane which allows one component of a solution to pass through it and not the others.
  • Page 80 As the feed water temperature decreases so will the product water production. The rated product flow (gallons per minute, gpm) as shown for the various models on page 3 is based upon the feed water temperature equal to 77° F. Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 81 *Short term cleaning is acceptable for pH ranges between 2.0/12.0. Additional treatment is required when chloramines are present and the pH levels exceed 9.0. NOTICE In some applications, a water softener is not required. Consult an independently operated Culligan dealer for further information on these special applications. Cat. No. 01022940...
  • Page 82: Index

    Wiring 26, 27, 43, Electrical Installation Parts 44, Plumbing Installation Prefilter Cartridge 8, Features Pressure Gauge Feed Assembly 46, Pressure Switch Feed Water Connections Pressure Transducer Feed Water Limits Pressurized Storage Tank Filter Pretreatment Lockout Cat. No. 01022940 Culligan® M1 Series Reverse Osmosis...
  • Page 83 Notes Cat. No. 01022940 Notes...