WARNING
Personal Injury. Stop immediately if the mast hangs
up or the winch cable develops slack. Excess slack
could cause the mast to collapse, resulting in personal
injury or equipment damage.
4. Rotate the mast by loosening the mast rotation
knob at the bottom of the mast (D). Turn the mast
until the lights face in the desired direction and
then tighten the knob to secure the mast in
position.
WARNING
Tipping hazard. Do not extend the mast beyond the
colored mark on the second mast section. The unit
can become unstable and tip or fall, causing injury.

Preparing for Start-Up

NOTE: If the engine was run out of fuel or the fuel tank was
drained, it may be necessary to bleed the fuel lines before
starting. Refer to the engine manual supplied with the unit.

Select AUTO or MANUAL Mode

See
Figure
3-3. Using the arrows on the Power Zone–
DLA, select either AUTO or MANUAL on the Home
screen.
AUTO
mode
is
automatic start and stop times (see
Screen), or enabling the "Night Watchman" sensor
(see
Scheduler
Screen.)
MANUAL mode is used for on-demand control of
the lights and convenience outlets.
Figure 3-3. Selecting MANUAL or AUTO Mode
Owner's Manual for MLT4200IVF4 Light Tower
(000265)
(000262)
required
for
programming
Scheduler
002354

Configure for Intended Use

As described in "General Information", the engine in this
unit runs at low speed when the LED lights are operating
and no loads are connected to the 120 or 240V
convenience outlets. The engine runs at high speed
when the LED lights are turned off. Therefore, before
starting, determine if auxiliary equipment will be
connected to the convenience outlets. Then set up the
unit based on the intended use:
LED Lights Only
Turn the 240V outlet breaker OFF. The engine will run at
low speed while operating, greatly reducing sound
emissions and fuel consumption.
LED Lights and Export Power
Turn the 240V outlet breaker ON and Load Sense OFF.
The engine will run at high speed for powering high
amperage equipment.
LED Lights and Export Power with Load Sense
Turn the 240V outlet breaker ON and Load Sense ON.
The engine will run at high speed when detecting applied
load(s) such as hand tools and low amperage equipment.
Table 3-1
illustrates the four possible combinations of
240V outlet breaker and Load Sense switch positions.
Table 3-1. Engine Speed Selection
ON
240VAC
Outlet
Breaker
OFF
*Engine will speed up automatically when more
power is drawn from receptacles.

Emergency Stop Switch

See
Figure
3-4. The unit is equipped with one
emergency stop switch. For location of the emergency
stop switch, refer to
Component
switch is clearly labeled EMERGENCY STOP. The switch
can be accessed and activated with all doors closed and
locked.
Activate the emergency stop switch by pushing the red
button in until it locks down. This will trip the main circuit
breaker which will open the contact, disconnecting the
load to the connection lugs. This will also open the fuel
circuit, shutting down the engine.
Operation
Load Sense Switch
ON
OFF
Load
dependent—
High speed
variable speed*
Low speed
Low speed