RIGOL Installation Guide RM-DS-1 Rackmount Kit DS1000 Series, DS1000CA Series, DS1000E Series, DS1000D Series Digital Oscilloscope May 2009 RIGOL Technologies, Inc.
Page 2
Notices RIGOL products are protected by patent law in and outside of P.R.C.. RIGOL Technologies, Inc. reserves the right to modify or change parts of or all the specifications and pricing policies at company’s sole decision. Information in this publication replaces all previously corresponding material.
Symbols on the Product. These symbols may appear on the product: Protective Hazardous Refer to Chassis Test Earth Voltage Instructions Ground Ground Terminal Installation Guide for RM-DS-1 Rackmount Kit...
The machine cabinet should be a standard 19-inch. At least 4U spaces (177.8mm) have to be provided by machine cabinet. The depth inside the machine cabinet should not be less than 165mm. Figure 3: Dimension of Instrument with Rack Adapter Installed Installation Guide for RM-DS-1 Rackmount Kit...
Install the left and right plate: aim the detents of both right and left plate at the openings on support board and insert selectively, then fix them using four M4 bolts. Figure 4: Installation of Left and Right Plate Installation Guide for RM-DS-1 Rackmount Kit...
Page 7
Place the instrument: first, put the instrument onto the support board and then generally slide it into right position down the baby hem on either side, exposing the front of instrument from the opening of front panel. Figure 6: Place the Instrument Installation Guide for RM-DS-1 Rackmount Kit...
Page 8
Loading into machine cabinet: mount the rack with instrument-fixed onto a standard 19-inch machine cabinet respectively using 4 M6 bolts and square nuts and then put the hanging ring back in position. Figure 8: Loading into machine cabinet Installation Guide for RM-DS-1 Rackmount Kit...
Page 9
A ship type switch is used to turn ON or OFF the instrument once the power switch above the instrument has been pressed down. Power input Ship type switch Power source Figure 10: Power Cord Connection of Rack Installation Guide for RM-DS-1 Rackmount Kit...
Page 10
RIGOL Contact Us If you have any problem or requirement during using our products, please contact RIGOL Technologies, Inc. or your local distributors. Domestic: Please call Tel: (86-10) 8070 6688 Fax: (86-10) 8070 5070 Service & Support Hotline: 800 810 0002 9:00 am –5: 00 pm from Monday to Friday...