First Commissioning; Touch Calibration; Fig. 9-3: Touch Calibration Of The Indracontrol Vep - Bosch Rexroth IndraControl VEP .2 Series Project Planning Manual

The embedded terminals are pc-based machine operator terminals
Table of Contents

Advertisement

9-2
Software
9.2

First Commissioning

9.3

Touch Calibration

To be able to configure the IndraControl VEP devices comfortably during
the first commissioning, the configuration applications touch calibration
and the Rexroth CE Settings start automatically. For just delivered
devices these settings are already made ex works.
Note:
To reset the IndraControl VEP to its original status, (e. g. the
device cannot be operated because of wrong touch
calibration), file boot.boo can be deleted in the main directory
of the CompactFlash card. If you restart the IndraControl VEP
the device behaves like after the first start.
Touch exactly the 4 calibration points one after each other with a touch
pen (red point at the arrowhead). After having actuated the last calibration
point, the display changes to the Windows desktop after a waiting time of
approx. 5 seconds. Now, the proper calibration of the touch can be tested
and can be confirmed with "OK".
If the touch calibration shall be repeated later, it can be started via the
desktop icon "Touch Calibration" or via the start menu Start – Program
Files – Tools – Touch Calibration.
Fig. 9-3:
Touch calibration of the IndraControl VEP
After the touch calibration the configuration tool "Rexroth CE Settings"
starts automatically.
IndraControl VEP30.2 40.2 and 50.2
DOK-SUPPL*-VEP**.2****-PR01-EN-P
Calibration.bmp