Used Standards; Fig. 4-8: Used Standards - Bosch Rexroth IndraControl VEP .2 Series Project Planning Manual

The embedded terminals are pc-based machine operator terminals
Table of Contents

Advertisement

4-4
Technical Data
4.6

Used Standards

UL/CSA Certification
The system components of the embedded terminals IndraControl VEP
correspond to the following standards:
Standard
EN 60 204-1
EN 50 081-2
EN 50 082-2
EN 60 742
EN 60 950
EN 61 131
EN 61 131-2
EN 418
EN 60 529
EN 60 068-2-6
EN 60068-2-27
Fig. 4-8:
Used standards
Note:
Concerning
requirements are fulfilled. After plugging-in extension cards,
however, a new CE test has to be executed.
The devices of the IndraControl VEP family are basically certificated
according to
• UL508 (Industrial Control Equipment) and
• C22.2 No. 14-M95 (CSA)
However, it is possible that there are combinations or extension stages
with restricted or missing certification. Thus, verify the registration
according to the UL marking on the device.
Note:
To guarantee an UL/CSA-compliant operation, you have to
fulfill the following conditions:
• Use 60/75 °C copper wire only.
• Use Class 1 wire only or equivalent.
Note:
The UL/CSA marking is only valid for the device in its delivery
status. After having modified the device, e. g. after plugging-in
additional extension cards, the UL compliancy has to be
verified.
IndraControl VEP30.2 40.2 and 50.2
Meaning
Electrical equipment of machines
Basic technical standard, emitted interference
(industrial environment)
Basic technical standard, noise immunity (industrial
environment)
Transformer for 24 V power supply unit, protective
separation
Overvoltage category II
Requirements concerning the 24 V outputs
Requirements concerning the 24 power supply
Machine safety, EMERGENCY STOP devices
Degrees of protection (incl. housings and installation
compartments)
Vibration test
Shock test
delivered
embedded
DOK-SUPPL*-VEP**.2****-PR01-EN-P
terminals
all
CE