Software; General Information; First Commissioning; Touch Screen Calibration - Bosch Rexroth IndraControl VEH 30.1 Project Planning Manual

Hand-held terminal
Hide thumbs Also See for Rexroth IndraControl VEH 30.1:
Table of Contents

Advertisement

Project Planning Manual | Rexroth IndraControl VEH 30.1
9

Software

9.1

General Information

Ordering designation
FWA-VEH*01-CWN-01VRS-EN
Ordering designation
SWS-WINSTU-RUN-06VRS-D0-WCE1K5
SWS-WINSTU-RUN-06VRS-D0-WCE4K
9.2

First Commissioning

9.3

Touch Screen Calibration

The IndraControl VEH 30.1 is delivered with the embedded operating system
Microsoft Windows CE .NET 4.2. The operating system is contained in the
firmware (FWA) that you must order in addition to the IndraControl VEH 30.1.
Furthermore, this firmware (FWA) contains the visualization software WinStu‐
dio "lite". The functional range of the visualization software WinStudio "lite" is
restricted. For extended functionality range you must order a license.
The following tables provide an overview of the available licenses.
Part number
R911310833
Fig.9-1:
Firmware type of the IndraControl VEH 30.1
Part number
R911306954
R911306951
Fig.9-2:
Software options
Do all required settings of the IndraControl VEH 30.1, especially the
network settings, with the configuration dialog "Rexroth CE Set‐
tings". Settings directly made in the control panel of Windows CE
are overwritten by the Rexroth CE Settings!
All settings made under Windows CE are saved in the Windows CE
registration database. Therefore you must save them after each
modification:
With the desktop icon "Save Registry"
or
With Start Programs Tools Save Registry
For the IndraControl VEH 30.1 default values are set and the touch screen is
precalibrated ex works. If you have executed a system update, the application
to calibrate the touch screen is automatically started during the first commis‐
sioning. See
chapter 9.3 "Touch Screen Calibration" on page
tool to set the network and application data is automatically set. See
9.4 "Rexroth CE Settings" on page
If the position of the mouse pointer differs from the point that is touched on the
display, you can recalibrate the touch screen. You can start the calibration pro‐
Electric Drives
| Bosch Rexroth AG
and Controls
Description
IndraControl VEH 30.1: Windows CE
4.2 .NET with preinstalled WinStudio
"lite".
Description
WinStudio Runtime license
Max. 1,500 variables, 256 array ele‐
ments, 32 class elements
WinStudio Runtime license
Max. 4,000 variables, 512 array ele‐
ments, 32 class elements
48.
47/68
Software
47. Then the
chapter