Troubleshooting

Fault
Desk does not move
Desk only lowers
slowly
Desk only moves
slowly
Desk only moves
briefly on one side
and then remains
stationary
9051_Bedienungsanleitung_C1_Rev2_EN_UK – Stand 08.08.2018 TS / MB
Cause
No power supply
No connection or loose
connection to the
drives/side panels
No connection to the
hand-switch
Max. lifting force
exceeded
Max. operating time
exceeded
Drive defective
Controller defective
Actuator defective
Controller expects a
reinitialisation
Max. lifting force
exceeded
No connection or loose
connection to the
drives/side panels
Drive defective
Repair
Plug in mains cable;
if applicable, check the plug connector on the controller.
Check, if applicable fix plug connector connection from the
motor cable to the controller and the drives.
Check, plug-in plug connector to the controller.
Reduce weight.
The controller will independently reactivate
after approx. 3 minutes.
ATTENTION!
The max. travel time of 2 minutes is only available after an
idle time of at least 18 minutes.
Please contact Customer Service.
Please contact Customer Service.
Replace actuator
See Section 5 Reinitialisation.
Reduce weight.
Check, if applicable fix plug connector connection from the
motor cable to the controller and the drives.
Please contact Customer Service.