Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
fireplace is to be vented out the top or out the rear.
NOTICE: Some fireplaces cannot be vented out the rear of the
fireplace.
Determine how the vent system will be terminated out the side of
the house or through the roof. Verify clearances for the termination.
See Empire Comfort Systems Retail Price List for Simpson Duravent part numbers and pricing.
DVVk-4VP
Direct-Vent Fireplace Vent kit - Vertical, Includes SD46DVA-VCH, SD46DVA-SC and SD46DVA-F6
Direct-Vent Fireplace Vent kit for Top Vent, Thru-the-wall, 8 to 11 inch wall thickness, Includes SD46DVA-08A,
DVVk-4TP
SD46DVA-09, SD46DVA-HC, SD46DVA-E90 and SD46DVA-WT
Direct-Vent Fireplace Vent kit for Top Vent, Thru-the-wall, 5 to 7 inch wall thickness, Includes SD46DVA-06,
DVVk-4TSP
SD46DVA-HC, SD46DVA-E90 and SD46DVA-WT
DVVk-4FV *
Direct-Vent Fireplace Vertical Flex Vent kit
DVVk-4RE *
Direct-Vent Fireplace Vent kit, Thru-the-wall, 5 to 13 3/4 inch wall thickness
Direct-Vent Fireplace Vent kit for Rear Vent, 6 to 12 inch wall thickness, Includes SD58DVA-06, SD58DVAWTEC,
DVVk-5RP
and SD58DVAHC
Direct-Vent Fireplace Vent kit for Top Vent, Thru-the-wall, 4 to 6 inch wall thickness, Includes SD58DVA-E90,
DVVk-5TP
SD58DVA-HC, SD58DVA-06, and SD58DVAWTEC
DVVk-5VP
Direct Vent Fireplace Vent kit - Vertical, Includes SD58DVA-VCH, SD58DVA-SC, and SD58DVA-F6
DVVk-5F *
Horizontal Flex Vent Kit (4' Flex) (1.22m)
NOTE: DVx42FP appliances can use the DVVk-4 vent systems only if using a DVA47 adaptor.
* Empire Flex-Vent kits
39357-0-1018

VENT SYSTEM IDENTIFICATION

Special Venting Components (Simpson Duravent)
Special Dv vent Kits for DvX42
Available from Empire Comfort Systems, Inc. dealers.
When selecting a vent system for use with the fireplace, refer to
the "Special Vent Systems" section in this manual to determine
what systems are acceptable. Check all clearances and venting
components. Identify if any problems existing in the vent system.
Use Figure 20 on page 18 for top venting to eliminate issues after
installation. Check pipe diameter on vent system and fireplace to
verify the size is the same.
NOTICE: All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.
*NOTE: If using three 90° elbows during horizontal
termination, see Figure 28.