Sirona CEREC MC XL Operating Instructions Manual

Sirona CEREC MC XL Operating Instructions Manual

Dental cad/cam system
Table of Contents

Advertisement

MRKOMNN
kÉï=~ë=çÑW=
páêçå~=aÉåí~ä=`^aL`^j=póëíÉã
`bob`=j`=ui
léÉê~íáåÖ=fåëíêìÅíáçåë
båÖäáëÜ=ErpF
Operating instructions

Advertisement

Table of Contents
loading

Summary of Contents for Sirona CEREC MC XL

  • Page 1 MRKOMNN kÉï=~ë=çÑW= páêçå~=aÉåí~ä=`^aL`^j=póëíÉã `bob`=j`=ui léÉê~íáåÖ=fåëíêìÅíáçåë båÖäáëÜ=ErpF Operating instructions...
  • Page 2: Table Of Contents

    Note PC / Acquisition Unit ................Warranty......................General description ....................Certification ....................Intended use ....................Further use of Sirona Dental CAD/CAM System .......... Safety ........................Basic safety information ................4.1.1 Prerequisites ..................4.1.2 Maintenance and repair ..............4.1.3 Changes to the product..............
  • Page 3 Sirona Dental Systems GmbH Operating Instructions Sirona Dental CAD/CAM System 5.4.6.1Connecting to the PC via LAN ............5.4.6.2Connecting the milling unit to the power supply ........ 5.4.6.3Installing the unit ................5.4.6.4Connecting to the PC via WLAN (option) .......... 5.4.6.5Operating several milling units over one access point ......
  • Page 4 Sirona Dental Systems GmbH Operating Instructions Sirona Dental CAD/CAM System System requirements ..................Milling unit ..................... 8.2.1 General technical description............. 8.2.2 Technical data..................8.2.3 Controller board ................. Disposal........................Index......................... 63 33 608 D 3439 D 3439.201.02.14.23 05.2011...
  • Page 5: Dear Customer

    Dear Customer, Dear Customer, General description ® Thank you for purchasing your CEREC MC XL from Sirona. This device enables you to produce dental restorations, e.g. from ceramic material with a natural appearance (CEramic REConstruction). Improper use and handling can create hazards and cause damage.
  • Page 6: General Information

    2 General information Sirona Dental Systems GmbH 2.1 Identification of danger levels Operating Instructions Sirona Dental CAD/CAM System General information General information CAUTION Be sure to observe all warnings! Please observe the warning and safety information provided to prevent personal injury and material damage. Any such information is highlighted by a signal word, i.e.
  • Page 7: Formats And Symbols Used

    Sirona Dental Systems GmbH 2 General information Operating Instructions Sirona Dental CAD/CAM System Formats and symbols used Formats and symbols used The symbols and character formats used in the present manual have the following meaning: ✔ Requests you to do something.
  • Page 8: General Description

    3 General description Sirona Dental Systems GmbH 3.1 Certification Operating Instructions Sirona Dental CAD/CAM System General description General description Certification Certification CE mark This product bears the CE mark in accordance with the provisions of directives 2006/95/EC (Low Voltage Directive) and 2004/108/EC (EMC Directive).
  • Page 9: Intended Use

    Intended use Intended use Indications for use The Sirona Dental CAD/CAM System is intended for use in partially or fully edentulous mandibles and maxillae in support of single or multiple- unit cement retained restorations. The system consists of three major parts: TiBase, inCoris mesostructure, and CAD/CAM software.
  • Page 10: Safety

    ● The Maintenance and repair of this unit may be performed only by Sirona or by agencies authorized by Sirona. ● Components which have failed and influence the safety of the unit must be replaced with original (OEM) spare parts.
  • Page 11: Accessories

    Disturbance of data transmission Disturbance of data transmission Note on wireless communication Data communication between the acquisition unit and the CEREC MC XL milling unit should preferably be implemented via the wireless H&W interface or WLAN. As for all wireless connections (e.g. mobile telephones) heavy utilization of the available radio channels or shielding caused by building installations (e.g.
  • Page 12: Installation And Startup

    Transport and unpacking Transport and unpacking Transport and unpacking All Sirona products are carefully checked prior to shipment. Please perform an incoming inspection immediately after delivery. 1. Check the delivery note to ensure that the consignment is complete. 2. Check whether the product shows any visible signs of damage.
  • Page 13: Installation Site

    Sirona Dental Systems GmbH 5 Installation and startup Operating Instructions Sirona Dental CAD/CAM System Installation site Installation site CAUTION Install out of the reach of patients! Do not install or operate the milling unit in the vicinity of the patient (place it at least 1.5 m away from the patient).
  • Page 14: Functional Elements

    5 Installation and startup Sirona Dental Systems GmbH 5.4 Initial startup Operating Instructions Sirona Dental CAD/CAM System 5.4.1 Functional elements Functional elements Unit overview Overview of the milling unit Milling chamber ON/OFF switch Milling chamber Drawer door catch Display Water tank...
  • Page 15 Sirona Dental Systems GmbH 5 Installation and startup Operating Instructions Sirona Dental CAD/CAM System CEREC milling chamber Milling chamber Milling chamber Bur set 1 Ceramic block Bur set 2 (optional) Workpiece spindle Motor mount 63 33 608 D 3439 D 3439.201.02.14.23 05.2011...
  • Page 16: Display Description

    5 Installation and startup Sirona Dental Systems GmbH 5.4 Initial startup Operating Instructions Sirona Dental CAD/CAM System 5.4.2 Display description Display description These operating instructions describe how to operate the unit by executing and confirming commands via your PC. "Start"...
  • Page 17: Inserting The Milling Chamber Sieve

    Sirona Dental Systems GmbH 5 Installation and startup Operating Instructions Sirona Dental CAD/CAM System 5.4.4 Inserting the milling chamber sieve Inserting the milling chamber sieve CAUTION Risk of injury on milling instruments Be careful not to brush against the milling instruments with your hand.
  • Page 18: Installation

    5 Installation and startup Sirona Dental Systems GmbH 5.4 Initial startup Operating Instructions Sirona Dental CAD/CAM System 5. Insert the block clamp tool on the left and the bar code reader on the right. 6. If you want to turn the tool holder, take the tools out again, remove the holder, turn and reposition it.
  • Page 19: 2Connecting The Milling Unit To The Power Supply

    Sirona Dental Systems GmbH 5 Installation and startup Operating Instructions Sirona Dental CAD/CAM System 5.4.6.2 Connecting the milling unit to the power supply Connecting the milling unit to the power supply NOTICE Grounded power outlet The milling unit must be connected to a grounded power outlet.
  • Page 20: 4Connecting To The Pc Via Wlan (Option)

    5 Installation and startup Sirona Dental Systems GmbH 5.4 Initial startup Operating Instructions Sirona Dental CAD/CAM System NOTICE IP address You will find the IP address on your unit's display. ✔ The unit is connected to the power supply. ➢ Switch the unit on, see the chapter on "Switching the unit on and off“...
  • Page 21 Sirona Dental Systems GmbH 5 Installation and startup Operating Instructions Sirona Dental CAD/CAM System 2. Perform a communication test as described in the separate instructions (see "Operating MC XL via WLAN in infrastructure mode", chapter "Final work, analyzing connection quality"). If applicable, follow the instructions on changing channels.
  • Page 22: 5Operating Several Milling Units Over One Access Point

    ● 1x LAN switch (e.g. Netgear ProSave 5 Port Gigabit Switch, Model GS105) ● 1x LAN network cable (10m, Sirona Order No.: 61 51 521). LAN switch, connection example with 2 milling units 1. Connect the LAN port (A) of the MC XL milling unit with the LAN switch using the included 10m LAN network cable.
  • Page 23: Filling The Water Tank

    Sirona Dental Systems GmbH 5 Installation and startup Operating Instructions Sirona Dental CAD/CAM System 5.4.7 Filling the water tank Filling the water tank Note on the tank cap opener NOTICE Using the tank cap opener If you find the tank cap, tank drain or filter insert hard to open by hand, use the tank cap opener (see "Using the tank cap opener"...
  • Page 24: Switching The Unit On And Off

    5 Installation and startup Sirona Dental Systems GmbH 5.4 Initial startup Operating Instructions Sirona Dental CAD/CAM System 7. Push the water tank back into the housing. 8. Switch the unit on (see Switching the unit ON and OFF [ → 24]).
  • Page 25: Repacking

    Sirona Dental Systems GmbH 5 Installation and startup Operating Instructions Sirona Dental CAD/CAM System "Pump" You can start or stop the water pump by pressing the button (C). This enables you to drain the water circuit without connecting to the PC (e.g.
  • Page 26: Operation

    6 Operation Sirona Dental Systems GmbH 6.1 Configuration (CEREC MC XL) Operating Instructions Sirona Dental CAD/CAM System Operation Operation CAUTION Risk of injury on calibration pins/milling instruments If you reach into the milling chamber (e.g.: when inserting/removing a ceramic block, changing milling instruments, or inserting/removing a calibration phantom), you may injure your hand on the calibration pins/ milling instruments.
  • Page 27: Calibrating The Unit

    Sirona Dental Systems GmbH 6 Operation Operating Instructions Sirona Dental CAD/CAM System In all of these cases, you can deactivate sets 1 and 2 separately in the "Device Configuration" dialog box. A deactivated set will simply be ignored during milling, calibration etc.
  • Page 28 6 Operation Sirona Dental Systems GmbH 6.2 Calibrating the unit Operating Instructions Sirona Dental CAD/CAM System NOTICE Faulty milling result If the unit is not calibrated, the milling result may be faulty. ✔ Take the calibration pins and calibration phantom out of the drawer of the unit.
  • Page 29: Starting The Milling Process

    Sirona Dental Systems GmbH 6 Operation Operating Instructions Sirona Dental CAD/CAM System 7. To insert the calibration phantom in the block clamp, grasp it by its narrow surfaces (B). 8. Clamp the calibration phantom with the ball pressure screw. Use the block clamp tool for this purpose.
  • Page 30 6 Operation Sirona Dental Systems GmbH 6.3 Starting the milling process Operating Instructions Sirona Dental CAD/CAM System Starting the milling process NOTICE Selecting the milling instruments Following installation, the inserted combination of milling instruments may still be unknown to the software. In this case, a dialog box will...
  • Page 31: Entering The Bar Code

    Sirona Dental Systems GmbH 6 Operation Operating Instructions Sirona Dental CAD/CAM System 10. Remove the restoration. WARNING Risk of injury on the remainder of the ceramic block The remaining portion of the ceramic block may have sharp edges (e.g. A) that could injure you if it is not removed carefully.
  • Page 32: Using The Manual Block Clamp

    6 Operation Sirona Dental Systems GmbH 6.4 Using the manual block clamp Operating Instructions Sirona Dental CAD/CAM System Using the manual block clamp Using the manual block clamp Store the block clamp tool in the corresponding holder (see also "Gluing on the tool holder"...
  • Page 33 Sirona Dental Systems GmbH 6 Operation Operating Instructions Sirona Dental CAD/CAM System Blocks with 6 mm diameter block holders Fastening the block NOTICE Fasten the block tightly If the block is not tightened sufficiently, this may result in falsification of the milling result and fracturing of its ceramic material.
  • Page 34: Maintenance

    NOTICE Do not confuse the block screw with the ball pressure screw When operating a CEREC 3 milling unit and a CEREC MC XL milling unit in the same room, be careful not to confuse the block screw of the CEREC 3 with the ball pressure screw of the CEREC MC XL.
  • Page 35: Changing The Water

    Sirona Dental Systems GmbH 7 Maintenance Operating Instructions Sirona Dental CAD/CAM System Changing the water Changing the water 7.1.1 General information General information NOTICE Damage to the pump and milling drives! An excessively high ceramic content in the cooling water will damage the pump and milling drives.
  • Page 36: Changing The Water

    7 Maintenance Sirona Dental Systems GmbH 7.1 Changing the water Operating Instructions Sirona Dental CAD/CAM System 7.1.2 Changing the water Changing the water To change the water, proceed as follows: ✔ The unit is switched on. ✔ No milling/scanning process is running.
  • Page 37: Milling Instruments

    Sirona Dental Systems GmbH 7 Maintenance Operating Instructions Sirona Dental CAD/CAM System Milling instruments Milling instruments Second bur set NOTICE Second burr set The following information on the two but sets is only applicable if the second but set (optional) is also installed.
  • Page 38: Changing Milling Instruments (Burs)

    7 Maintenance Sirona Dental Systems GmbH 7.2 Milling instruments Operating Instructions Sirona Dental CAD/CAM System 7.2.2 Changing milling instruments (burs) Changing milling instruments (burs) NOTICE Milling instruments without chuck In order to ensure that no grease residues from previously used chucks remain in the clamping cone when using milling instruments without a chuck, we urgently recommend degreasing the clamping cone.
  • Page 39 Sirona Dental Systems GmbH 7 Maintenance Operating Instructions Sirona Dental CAD/CAM System 6. NOTICE!Do not grease the milling instrument without chuck! Insert the new milling instrument into the motor mount by hand. Tighten the corresponding chuck with the torque wrench until a clicking sound can be heard.
  • Page 40: Care And Cleaning Agents

    Cleaning surfaces NOTICE Care and cleaning agents Use only cleaning and care agents which have been approved by Sirona, see Cleaning and care agents [ → 40]. NOTICE Do not allow liquids to run into the ventilation slots! 7.4.1 Disinfecting Disinfecting Wipe surfaces down with a surface disinfectant (wiping disinfectant).
  • Page 41: Replacing The Main Fuses

    Sirona Dental Systems GmbH 7 Maintenance Operating Instructions Sirona Dental CAD/CAM System Replacing the main fuses Replacing the main fuses Warning: main fuse WARNING Electric shock Disconnect the power plug at the unit end before replacing the fuses. NOTICE Fuse type...
  • Page 42: Changing The Filter

    7 Maintenance Sirona Dental Systems GmbH 7.6 Changing the filter Operating Instructions Sirona Dental CAD/CAM System Changing the filter Changing the filter NOTICE Change the filter regularly! Clean the filter regularly and change it immediately when damaged. Otherwise, change it every 3 months.
  • Page 43: Removing Water From The Unit

    Sirona Dental Systems GmbH 7 Maintenance Operating Instructions Sirona Dental CAD/CAM System Removing water from the unit Removing water from the unit You must remove water from the unit if you will not be using it for a longer period of time or wish to transport it.
  • Page 44 7 Maintenance Sirona Dental Systems GmbH 7.8 Using the tank cap opener Operating Instructions Sirona Dental CAD/CAM System Opening the filter cap ✔ The water tank has been pulled out and drained. ➢ Place the tank cap opener on the filter cap as shown, and take off the filter cap by unscrewing it counter-clockwise.
  • Page 45: Technical Description

    Sirona Dental Systems GmbH 8 Technical description Operating Instructions Sirona Dental CAD/CAM System Technical description Technical description System requirements System requirements Working without the acquisition unit An inLab system PC is required to run this software. The hardware version must be PC Hardware A or higher.
  • Page 46: Technical Data

    8 Technical description Sirona Dental Systems GmbH 8.2 Milling unit Operating Instructions Sirona Dental CAD/CAM System 8.2.2 Technical data Technical data Type designation Milling unit CEREC MC XL Rated line voltage 100V - 230V AC Rated power frequency 50/60 Hz Rated current 1.5 - 3.5 A...
  • Page 47: Disposal

    Sirona Dental Systems GmbH 9 Disposal Operating Instructions Sirona Dental CAD/CAM System Disposal Your product is marked with the adjacent symbol. Within the European Disposal Economic Area, this product is subject to Directive 2002/96/EC as well as the corresponding national laws. This directive requires environmentally sound recycling/disposal of the product.
  • Page 48: Index

    Sirona Dental Systems GmbH Operating Instructions Sirona Dental CAD/CAM System Index Barcode reader, 14 Filter Building installation, 10 change, 42 Order Number, 42 floor space, 13 Calibration tools Fuse, 14 Calibration phantom, 27 Fuse type, 41 Calibration pins, 27 Order No., 41...
  • Page 49 Sirona Dental Systems GmbH Operating Instructions Sirona Dental CAD/CAM System Packaging, 12 Warranty, 7 Packing, 25 water, 46 port Water tank WLAN, 20 Change water, 36 Ports, 14 Filling the, 23 Power connection, 14 Odors, 35 Product safety, 11 Overview, 23, 42...
  • Page 50 tÉ=êÉëÉêîÉ=íÜÉ=êáÖÜí=íç=ã~âÉ=~åó=~äíÉê~íáçåë=ïÜáÅÜ=ã~ó=ÄÉ=êÉèìáêÉÇ=ÇìÉ=íç=íÉÅÜåáÅ~ä=áãéêçîÉãÉåíëK «=páêçå~=aÉåí~ä=póëíÉãë=dãÄe=OMNMJOMNN péê~ÅÜÉW ÉåÖäáëÅÜ=ErpF mêáåíÉÇ=áå=dÉêã~åó a=PQPVKOMNKMOKNQKOP MRKOMNN ûKJkêKW= NNQ=NSM páêçå~=aÉåí~ä=póëíÉãë=dãÄe áå=íÜÉ=rp^W SP=PP=SMU=a=PQPV c~Äêáâëíê~≈É=PN páêçå~=aÉåí~ä=póëíÉãë=ii` lêÇÉê=kç SQSOR=_ÉåëÜÉáã QUPR=páêçå~=aêáîÉI=pìáíÉ=NMM dÉêã~åó `Ü~êäçííÉI=k`=OUOTP ïïïKëáêçå~KÅçã...