Laser Power Supply And Laser Module; Liquid Cooling System; Conductor Cross-Sections - Leister NOVOLAS Basic AT System Manual

Table of Contents

Advertisement

10.4 Laser power supply and laser module

Up to 4 laser modules and power supplies can be installed. Maximum ratings for the
individual modules are given below.
Laser safety class (system)
High power diode laser
Aiming laser
High power diode laser
wavelength
Aiming laser wavelength
High power diode laser
power
Aiming laser power
Type of operation
Min. bending radius of fiber

10.5 Liquid Cooling System

Cooling medium
Capacity
Filter unit
Water tube

10.6 Conductor cross-sections

0.25
2.5
1.6
Technical Data
Version 2.1
09/2010
Laser Class 4 according to EN60825-1
Laser Class 4 according to EN60825-1
Laser Class 2M according to EN60825-1
800-1000 nm
620-680 nm
Fiber coupled lasers: max. 400 W cw at aperture of
each laser module
max. 5 mW cw at aperture of each laser module
controlled current operation
Min.200 mm: for SMA fiber
Min. 250 mm for HiYAG fiber
de-ionized water
(conductivity: 5-10 µS, filtered < 20 µm)
approx. 3.5 liter (total incl. pump, filter and tubes)
20 µm
use only the tubes supplied by Leister!
Wires mm2
NOVOLAS Basic AT
Analog and digital signals such as
EMERGENCY STOP, Reset etc.
230 VAC (mains cable before fuse)
230 VAC (mains cable behind fuses)
Remark
61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents