3.
MB Circuit Board
(Time required: About 4 minutes)
3-1.
Remove the bottom MB assembly. (See procedure 2)
3-2.
Remove the eight (8) screws marked [30]. The MB
circuit board can then be removed. (Fig. 2)
*
Be careful not to move the circuit board excessively
as such movement will apply a stress to the LED.
*
When installing the MB circuit board, tighten screws
in the order of z to , as shown in Fig. 2.
v
b
4.
DSUB-PH Connector Assembly
(Time required: About 5 minutes)
4-1.
Remove the bottom MB assembly. (See procedure 2)
4-2.
Remove the four (4) screws marked [50A]. The sheet
protect plate can then be removed. (Fig. 3)
4-3.
Remove the two (2) screws marked [50B]. The earth
clamp can then be removed. (Fig. 4)
4-4.
Remove the DSUB-PH connector assembly. (Fig. 4)
SHEET PROTECT PLATE
(基盤保護プレート)
Fig. 3  ( 図 3)
[30]
c
MB
x
Fig. 2  ( 図 2)
3. 
MB シート
(所要時間:約 4 分)
3-1. 
ボトム MB Ass y を外します。 (2 項参照)
3-2. 
[30] のネジ 8 本を外して、MB シートを外します。
(図 2)
※ 
ネジ締め無しの状態でシートを著しく動かして LED にス
トレスをかけないように注意してください。
MB シートを取り付ける際は、図 2 に示す z 〜 , の順
※ 
にネジを締めてください。
z
n
4. 
DSUB-PH 束線
(所要時間:約 5 分)
4-1. 
ボトム MB Ass y を外します。 (2 項参照)
4-2. 
[50A] のネジ 4 本を外して、基盤保護プレートを外
します。 (図 3)
4-3. 
[50B] のネジ 2 本を外して、アースクランプを外し
ます。 (図 4)
4-4. 
DSUB-PH 束線を外します。 (図 4)
DSUB-PH CONNECTOR ASSEMBLY
Fig. 4  ( 図 4)
MBCL
[30]
m
,
(DSUB-PH 束線)
[50B]
[50B]
EARTH CLAMP