■ UPDATING DANTE MODULE (Brooklyn2)
1)
Equipment and material
PC: 1 unit, Windows XP with Ethernet port, Windows
Vista or Windows 7
Cable: Ethernet (CAT5e) straight cable
2)
Application
Dante Firmware Update Manager
Stored in ¥driver in Updata (CL_updata)
When DanteFirmwarUpdateManager***.msi is executed,
the updata will be installed.
(*** represents the version number)
* Premise: Bonjour is installed and operates properly.
* If the version of the firmware is not the latest one,
update it to the latest.
3)
Connection
Connect the PC and the primary port of CL with the
Ethernet (CAT5e) straight cable.
* Only the above connection is required and nothing
should be connected to any other terminal.
● Updating Procedure
1)
Turning on the power of CL.
Use the normal starting for updating.
2)
Starting Application
Using Firmware Update Manager provided by Audinate,
execute updating of the DANTE fi rmware.
(Started by Start menu – Program –Audinate – Dante
Firmware Update Manager – Dante Firmware Update
Manager)
Immediately after starting, the screen is as shown below.
Start the updating procedure by pressing the [Update
Dante Firmware] button.
3)
Selecting Firmware
Select the fi rmware to be updated. Press the [BROWSE]
button and the fi le selection message will appear. Select
FWUpdate_???_vxxxx_swxxx.dnt in brooklyn2¥ in
Updata (CL_Updata). (xxxx, xxx, represent version
numbers and ??? model name.)
The image here shows that of Rio3224-D but same with
CL except the fi le name/device name to be updated.
1 pc.
4)
Selecting Device
When CL connected to the network is found, it will be
included in the list of items to be updated.
Put a check mark at the left end of CL to be updated.
At this time, do not select more than one CLs. Execute
updating one by one.
5)
Executing updating
When the [START] button is pressed, a pop-up to
confi rm updating will appear.
While updating, use care so that no network disconnection
or CL power interruption occurs.
Pressing the [OK] button will start updating.
While updating, the screen display is as shown below
("Updating (1/1)" is indicated in the Status column.)
CL3/CL1