Freezer Location: Account Name _____________________________________
Street Address: ___________________________ Phone: _________________
City: ________________________________ State: ____ Zip: _____________
Distributor Name __________________________________________________
Dealer or Service Agency Name: _____________________________________
Street Address: ___________________________ Phone: _________________
City: ________________________________ State: ____
IMPORTANT:
This freezer must be installed by a qualified service technician in accordance with the
installation instructions. Contact the factory Service Department for more information
at 800-755-4545.
Installation
A. Position the Unit
1. Inspect freezer for any transit damage. .........
2. Check pulley alignment, belt tension,
set screws and bolt tightness. ........................
3. Install casters or legs. ....................................
4. Place freezer in proper location .....................
5. Level freezer by adjusting legs or casters.
Unit should have ¼" slope to the front. ..........
6. Allow 6" clearance for air flow. .......................
B. Electrical Wiring
Note: All connections must conform to local code requirements
and/or be in compliance with the National Electrical Code.
1. Check and record supply voltage at
disconnect.
2. Check wire condition and record wire size.
Record length of run from supply box.
3. Wire all 2 compressor freezers with
two (2) separate lines and disconnects. .......
4. Connect green ground wire to ground screw
lug in service entrance junction box. ............
5. Fuse freezers between maximum fuse size
and minimum circuit ampacity listed on freezer
data plate. Record fuse size or breaker rating. ____
6. Check beater rotation (Clockwise from front)
7. After installation, check and record voltage
at freezer under load. ....................................
8. After installation, check and record actual
operation amperage. ......................................
C. Water Connections (If applicable)
1. Connect water inlet line (cold water only) ......
3
(
/
" ID for single head, ½" ID for double head).
8
2. Connect drain line. .........................................
3. Turn water on and check for leaks. ................
D. Final Assembly for Freezers with Mix Transfer Systems
1. Unpack all spare parts for inspection. ............
2. Install and check any accessory item
purchased. ......................................................
3. Install refrigeration test gauges. .....................
4. Perform the Test of Installation outlined in
the Service Manual. .......................................
Page 1
INSTALLATION, START-UP AND INSTRUCTION
*For Freezers with Mix Transfer Systems
A
Left
Side
_____ v ______ v
______ GA _______ GA
_____ ft. _____ ft.
____
____
CHECKLIST
Zip: ____________
B
Operator/Owner Training
Right
Side
To avoid electrical shock or contact with
moving parts, make sure all switches are in
the "OFF" position and that the main power
supply is disconnected. Some freezers have
more than one disconnect switch.
1.
Review and explain Operator's Manual and caution
labels to operator/owner. .............................................
2.
Identify model and serial number tag.
Record in manual. .......................................................
3.
Explain and identify all control switches. ....................
4.
Instruct the owner/operator in assembly, lubrication and
disassembly procedures and explain the following: ..
a. Spigot/dispensing rod. ..........................................
b. Dispensing head, spigot and serrated nozzle or
spigot extension. ...................................................
c. Beater shaft, blades, shaft seal and bushing. ......
d. MTS hose assembly .............................................
e. Transfer hose, locating line and life
_____
(30 days maximum) ..............................................
f.
Duckbill check valve and air hose ........................
g. Air meter number identification and care ..............
_____
h. MTS housing and hose installation .......................
5.
Wash all cylinder and dispense head parts per manual
_____
instructions. Let air dry. ..............................................
6.
Wash cylinder with brush. ...........................................
7.
Wash mix inlet tube with brush. ..................................
8.
Explain lubrication points, reassemble and
install cylinder and head parts ....................................
9.
Reassemble and install mix transfer hose assembly.
10.
Before proceeding with demonstration, have
operator/owner disassemble, lubricate and
reassemble all parts. ...................................................
11.
Explain and identify function and cleaning of
drain tube. ...................................................................
12.
Explain and identify spare parts kit. ............................
Model No.: ___________________
Serial No.: ___________________
Voltage: _____________________
Phase: ______________________
Cooling: _____________________
Installation Date: ______________
Assembly & Cleaning
CAUTION