For single-phase power at 208–240V RMS:
CONNECTION
AC neutral
AC line
Ground (earth)
WARNING! It is not recommended to power any Vari-Lite luminaire from a dimmer - even in 'NONDIM' mode.
Dimmer and non-dim modules are not suitable sources of power because their output modifi es the AC wave
form. This may work for a short time, but will eventually result in power problems, luminaire mis-operation and/
or failure and may void the luminaire's warranty.

CURRENT VS. VOLTAGE

Total Luminaire Current is calculated with the LED on and all motors sequencing.
WARNING! It is the responsibility of the user to adequately protect supply source with a correct size and type
circuit breaker and not overload circuits.
AC VOLTAGE AT 60HZ
100V
110V
120V
130V
200V
210V
220V
230V
240V

CONNECTING DATA

A maximum of 32 luminaires may be connected in any one DMX data link.
NOTE: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may require
fewer luminaires on a single data link path. Consult your console documentation for more information.
To connect power and data:
Step 1.
Connect data cable from console to fi rst luminaire in chain at DATA IN connector.
Step 2.
If required, connect additional data cables from DATA THRU connectors to DATA IN
Step 3.
At last luminaire in link, install male termination connector at DATA THRU connector. (Luminaires and
other devices on the same DMX chain may not function properly without termination)
DMX512 CHANNELS
22 Channels
Data in
PIN
X
X
G
Y
G
Y
TOTAL LUMINAIRE CURRENT
(MOTOR + LED CURRENT)
3.03A
2.74A
2.54A
2.30A
1.49A
1.4A
1.36A
1.31A
1.25A
CHANNEL REQUIREMENTS**
DESCRIPTION
16BIT 1 Cell (Default)
Data thru
For three-phase power at 208V RMS:
CONNECTION
Phase 1
Phase 2
Ground (earth)
MENU DISPLAY
22
Data thru
2
QUICK START GUIDE
PIN
X
X
Y
G
Termination**
**DMX terminator required
for last fixture on DMX line
G
Y

Advertisement