Transport path sensor

► CS11D(A,B), CS21D(A,B), CS31D(A,B), CS41D(A,B)
1. Remove two M4 screws at both sides on the Sensor Bracket Assembly as shown in
the figure below.
2. For easy disassembly, cut a couple of connected cable ties around there.
3. Disconnect the connector and remove the cable tie to remove the Sensor Bracket
Assembly. Be careful not to break the connector pin when removing.
4. Remove the Sensor Bracket Assembly.
5. From the removed Sensor Bracket Assembly, remove the M3 screws (1 place each)
of the sensor which will be replaced.
6. Replace the sensor.
7. Assemble the unit in the reverse order of 5∼1
<Note!>
When assembling the Sensor Bracket Assembly, ensure to completely lift Sensor
Bracket Assembly up to have identical position between the face of sensor and
transport path, and then tighten the two bracket screws.
© 2013 Nautilus Hyosung Inc. All Rights Reserved.