Summary of Contents for AIC Caelum

  • Page 1 Caelum Server Motherboard User's Manual UM_Caelum_v1.1_102819...
  • Page 2: Table Of Contents

    Table of Contents Preface ������������������������������������������������������������������������������������������������� i Safety Instructions ������������������������������������������������������������������������������ ii About This Manual ������������������������������������������������������������������������������ iii Chapter 1� Product Features �������������������������������������������������������������� 1 1.1 Components ..................... 1 1.2 Specifications ..................2 1.3 Feature ..................... 3 Chapter 2� Hardware Setup ���������������������������������������������������������������� 4 2.1 Central Processing Unit ................4 2.1.1 Processor Installation ..................4 2.2 System Memory ..................
  • Page 3 4.4.3 NBIO Common Options ................... 24 4.4.4 FCH Common Options ..................25 4.5 Advanced ....................26 4.5.1 USB Configuration ................... 26 4.5.2 CPU Related setting ..................26 4.5.3 PCI SubSystem Setting ................... 26 4.5.4 OEMBOARD Function ..................27 4.5.5 SIO AST2500 ....................27 4.5.6 H2O IPMI Configuration .................
  • Page 4 Document Release History Release Date Version Update Content September User's Manual release to public. 2019 October Hardware spec update. 2019...
  • Page 5 Copyright © 2019 AIC, Inc� All Rights Reserved� This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements.
  • Page 6: Preface

    Disclaimer AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither AIC or its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost;...
  • Page 7: Safety Instructions

    Safety Instructions When installing, operating, or performing maintenance on this equipment, the following safety precautions should always be taken into account in order to reduce the risk of fire, electric shock, and personal injury. Carefully read the safety instructions below before using this product. •...
  • Page 8: About This Manual

    This document pellucidly presents a brief overview of the product design, device installation, and firmware settings for the Caelum motherboard. For the latest version of this user's manual, please refer to the AIC website:https://www.aicipc.com/en/productdetail/51127.
  • Page 9: Chapter 1� Product Features

    Chapter 1� Product Features Caelum User Manual Caelum User Manual Chapter 1. Product Features This section describes the hardware specifications and features of the Caelum motherboard. The fundamental components of the Caelum severboard are provided below. 1�1 Components Caelum Serverboard...
  • Page 10: 1.2 Specifications

    Caelum User Manual Chapter 1. Product Features 1.2 Specifications Single AMD EPYC™ 7000-series processor Processor • 2 x Intel I210 Ethernet Controller support dual (Rome/Naples) Support ports 1GbE with RJ45 connectors on rear I/O Network • Controller Realtek RTL8211E for BMC dedicated...
  • Page 11 Chapter 1. Product Features 1�3 Feature The Caelum server board uniquely features the latest single AMD EPYC™ 7000-series processor (Rome/Naples) and extensive memory capacity of 8 slots up to 2TB. Based on AMD Zen microarchitecture, distinguished for immense number of cores (64 cores for...
  • Page 12: Chapter 2� Hardware Setup

    Chapter 2� Hardware Setup Chapter 2. Hardware Setup Caelum User Manual This section describes a simple instruction guide for installing the hardware components on the serverboard system. Turn off and unplug all system and peripheral devices before proceeding. 2�1 Central Processing Unit The serverboard supports a single AMD EPYC™...
  • Page 13 Caelum User Manual Chapter 2. Hardware Setup Step 2 Lift the carrier frame by the blue metal tab and remove the protective cover as demonstrated in figure 3 and figure 4. Lift carrier frame. Remove protective cover. Front Front Step 3 Insert the CPU package into the carrier frame as demonstrated in figure 5.
  • Page 14 Chapter 2. Hardware Setup Caelum User Manual Step 5 Close the carrier frame with the CPU package as demonstated in figure 7. Check if the frame is properly installed as demonstrated in figure 8. Close carrier frame. Verify installation. Front...
  • Page 15: System Memory

    Caelum User Manual Chapter 2. Hardware Setup 2�2 System Memory This server board supports 8 DIMM memory slots with 1 DIMM per channel. 2�2�1 Installation Step 1 Unlock the DIMM socket by pressing the retaining clips outward. Step 2 Insert the memory module into the slot. Make sure that the DIMM notch is accurately positioned.
  • Page 16: Dimm Population

    Chapter 2. Hardware Setup Caelum User Manual 2�2�2 DIMM Population The DIMMs are displayed on the Spica board as DIMMD0, DIMMC0, DIMMB0, DIMMA0, DIMME0, DIMMF0, DIMMG0, and DIMMH0. To ensure satisfactory performance, you need to:  Verify the DIMM type: DDR4 RDIMM/LRDIMM/NVDIMM/Flash/3DS with ECC up to 2400 MHz ...
  • Page 17: Chapter 3� Motherboard Settings

    Caelum User Manual Chapter 3. Motherboard Settings This section provides illustrations that display the internal jumpers, connectors, and system LED indicators on the Caelum motherboard. The motherboard layout and essential connectors are listed below for your reference. 3�1 Motherboard Block Diagram...
  • Page 18: Content List

    Caelum User Manual Chapter 3. Motherboard Settings 3�2 Content List Connector and Header Location Connector and Header Location JPWR1 Power Connector JPWR2 Chassis Intrusion Header (2x4pin) JPWR3 JPWR4 Slimline x4 slot from Slim2 Remote Thermal Sensor PCIE G1 Slim3 Header...
  • Page 19: Connector And Jumper

    Caelum User Manual Chapter 3. Motherboard Settings 3�3 Connector and Jumper 3�3�1 Placement...
  • Page 20: Connector

    Caelum User Manual Chapter 3. Motherboard Settings 3�3�2 Connector 1a ~ 1d Power Connector 12 UART Header (J47) (JPWR1, JPWR2, JPWR3, JPWR4) SYS_UART_RTS1 2 SYS_UART_TXD1 5 +12V_S0 SYS_UART_DTR1 4 SYS_UART_RXD1 6 +12V_S0 SYS_UART_DSR1 6 SYS_UART_CTS1 7 +12V_S0 8 GND 8 +12V_S0...
  • Page 21 Caelum User Manual Chapter 3. Motherboard Settings Single Motor Fan Connector (JFAN5, JFAN6) 1 GND 2 +12V_S0 3 TACH 4 PWM 21 PMbus Header (J2) 1 SMB_PMBUS_CLK 2 SMB_PMBUS_DATA 3 PMBUS_ALERT_N_Q 4 GND 5 NC...
  • Page 22: Rear I/O

    Caelum User Manual Chapter 3. Motherboard Settings 3�3�3 Rear I/O 26 RJ-45 Ethernet (JLAN12) 24 USB 3.0 Type A Connector (USB1) 27 Serial Port (DSUB1) 25 RJ-45 Ethernet Port (JBMC_LAN2) 3�3�4 Jumper A CPU UART source selection (J48) Setting SYS_PWR_BTN_N come from switch...
  • Page 23: Led Indicator

    Caelum User Manual Chapter 3. Motherboard Settings 3�4 LED Indicator LED4 LED5 SATA_LED1 SATA_LED0 LED1 Blue (Solid) Identity system location. LED1 Chassis ID Blue (Blinking) Undefined. Dark Normal. Control by CPLD P0_PWR_GOOD Solid when Sequence is complete. LED4 Power good Blinking On going.
  • Page 24: Chapter 4. Bios Configuration Settings

    Chapter 4. BIOS Configuration Settings Caelum User Manual Chapter 4. BIOS Configuration Settings This chapter demonstrates how to configure the UEFI BIOS settings in your system device. You can enter the BIOS screen during system startup. To enter BIOS configuration settings, •...
  • Page 25: Bios Setup

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�2 BIOS Setup 4�2�1 Menu Bar Press  and  to select the options of the menu bar. Press Enter to access the option screen. Menu Description Displays system information such as CPU bus...
  • Page 26: Startup

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�2�2 Startup Step 1 Press ESC to run the BIOS setup procedure. Step 2 There will be a message “Entering SETUP” displayed on the diagnostics screen.
  • Page 27 Caelum User Manual Chapter 4. BIOS Configuration Settings Step 3 Identify the BIOS version. NOTE For the official released version, the last digit of the BIOS version must end in a “0.“ Step 4 Load Optimal Default Setting.
  • Page 28: Update

    Caelum User Manual Chapter 4. BIOS Configuration Settings Step 5 Save the setting and exit the BIOS setup utility. 4�2�3 Update To identify the latest BIOS version, please check the BIOS setup.
  • Page 29 Caelum User Manual Chapter 4. BIOS Configuration Settings Update BIOS by INSYDE H2OFFT-D utility under DOS environment If you need to update Flash in the DOS environment, please use H2OFFT-D utility. To use this utility, you must include the flash.bat , H2OFFT-D.exe, and bin file in the same folder.
  • Page 30: Main

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�3 Main 4�3�1 Main Main Option Key: Option Key Description System time Configures current time. System date Configures current date.
  • Page 31: Amd Cbs

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�4 AMD CBS AMD CBS: 4�4�1 Zen Common Options Zen Common Options Core Performance Boost Auto Disable Global C-state Control Auto Enable Disable Custom Core Pstates SEV-ES ASID Step=0x0,Min=0x1,Max=0x10 Space Limit Core/Thread Enablement...
  • Page 32: Umc Common Options

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�4�2 UMC Common Options UMC Common Options DDR4 DRAM Timing I Accept Auto Enable Overclock Common Configuration I Decline Options Common RAS DRAM Auto Configuration Symbol Size DRAM Auto Enable Disable Enable...
  • Page 33: Fch Common Options

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�4�4 FCH Common Options FCH Common Options Ac Power Ac Loss Control Always On Always Off Reserved Previous Loss Options...
  • Page 34: Advanced

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�5 Advanced Advanced Option Key: 4.5.1 USB Configuration USB Configuration USB Hardware SMI support Enable Disable USB Ports Per-Port Disable Enable Disable Control USB 3.0 Port 0~1 Enable Disable USB 2.0 Port 0~1...
  • Page 35: Oemboard Function

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�5�4 OEMBOARD Function OEMBOARD Function Messiah SMBIOS Updated SMBIOS Updated Auto By Utility Function Function 4�5�5 SIO AST2500 SIO AST2500 Serial Port A/B/D Enable Disable Base I/O Address Interrupt IRQ3/IRQ7 IRQ4/IRQ10 4�5�6 H2O IPMI Configuration...
  • Page 36: Console Redirection Setup

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�5�7 Console Redirection Setup Console Redirection Setup Console Serial Redirect Enable Disable Terminal Type VT_100 VT_100+ VT_UTF8 PC_ANSI 1200 2400 4800 9600 Baud Rate 19200 38400 57600 115200 Data Bits 7 bits...
  • Page 37: Security

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�6 Security 4�6�1 Security Security Option Key: Form 1 (Security) Current TPM Device Not Detected TPM2.0 TrEE Protocol Version TPM Availability Available Hidden PCR Bank: SHA1/ SHA256/SHA384/ None SHA512/SM3_256 Clear TPM None...
  • Page 38: Power

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�7 Power Power Option Key: Power Auto Wake on S5 By Everyday By Day of Month Disable Wake on S5 Time HH(0):MM(0):SS(0) Day of Month Min=1,Max=31...
  • Page 39: Boot

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�8 Boot 4�9�1 Boot Boot Option Key: Boot Boot Type Legacy Boot Type UEFI Boot Type Quick Boot Enable Disable Quiet Boot Enable Disable Network Stack Enable Disable PXE Boot to LAN...
  • Page 40: Save And Exit

    Caelum User Manual Chapter 4. BIOS Configuration Settings 4�9 Save and Exit 4�10�1 Save and Exit Save and Exit Option Key: Save and Exit Exit Saving Changes Exit system and save your changes. Save Change without Save your changes without exiting the system.
  • Page 41: Chapter 5. Bmc Configuration Settings

    Chapter 5. BMC Configuration Settings Caelum User Manual Chapter 4. BIOS Configuration Settings This chapter displays the configuration settings of IPMI BMC in your system device. 5�1 Login NOTE This feature works with the html5. Please use a browser that supports html5.
  • Page 42: Web Gui

    Caelum User Manual Chapter 4. BIOS Configuration Settings 5�2 Web GUI 5�2�1 Menu Bar Click to select the options of the menu bar. Menu Description The Dashboard page gives the overall information about the Dashboard status of a device. The Sensor Readings page displays all the sensor related Sensor information.
  • Page 43: User Information And Quick Button

    Caelum User Manual Chapter 4. BIOS Configuration Settings 5�2�2 User Information and Quick Button The user information and quick access buttons are located at the top right corner. It displays the logged-in user, his/her privilege and the four quick buttons allowing you to perform different functions.
  • Page 44 Caelum User Manual Chapter 4. BIOS Configuration Settings 5�2�3 Dashboard The Dashboard page displays device, system information, and assert logs. Click Dashboard on the menu bar to view the overall information of the server. 5�2�4 Sensor The Sensor page displays the status and records on related sensors. Click a record to...
  • Page 45: Fru Information

    Caelum User Manual Chapter 4. BIOS Configuration Settings 5�2�5 FRU Information The FRU Information page displays Basic Information, Chassis Information, Board Information and Product Information of the FRU device. Click FRU Information on the menu bar to view the details of the selected device.
  • Page 46: Logs And Report

    Caelum User Manual Chapter 4. BIOS Configuration Settings 5�2�6 Logs and Report The System Inventory page displays IPMI Event Log and Video Log. Click Logs and Reports from the menu bar and select Event Log or Video Log to view the contents.
  • Page 47: Settings

    Caelum User Manual Chapter 4. BIOS Configuration Settings 5�2�7 Settings The Settings page displays the configuration settings for Date & Time, External User Services, KVM Mouse Setting, Log Settings, Media Redirection Settings, Network Settings, PAM Order Settings, Platform Event Filter, Services, SMTP Settings, SSL...
  • Page 48 Caelum User Manual Chapter 4. BIOS Configuration Settings Settings Menu and Option Key: Settings Description Date and Time LDAP/E-directory Active directory Settings Radius Settings Settings External User General Advanced Services General Role General Role Radius Radius Settings Groups Settings Groups...
  • Page 49: Remote Control

    Caelum User Manual Chapter 4. BIOS Configuration Settings 5�2�8 Remote Control The Remote Control page displays the configuration for remote KVM and SOL. Click Java Console to start the JViewer video redirection.
  • Page 50 Caelum User Manual Chapter 4. BIOS Configuration Settings  Click Launch KVM to open the Remote KVM page.
  • Page 51 Caelum User Manual Chapter 4. BIOS Configuration Settings Procedure to Start KVM Step 1 Click Start KVM to start the H5Viewer video redirection. Step 2 Click Browse to select CD Image. Step 3 Click Start Media to redirect the selected CD image file to the Host.
  • Page 52 Caelum User Manual Chapter 4. BIOS Configuration Settings Remote KVM Menu and Option Key: Remote KVM Description Start KVM Starts the H5Viewer video redirection. Stop KVM Stops the H5Viewer video redirection. Pause Video This option is used for pausing Console Redirection.
  • Page 53 Caelum User Manual Chapter 4. BIOS Configuration Settings This menu item can be used to act Right <Ctrl> as the right-side <CTRL> key during Console Redirection. This menu item can be used to act Right <Alt> as the right-side <ALT> key during Console Redirection.
  • Page 54: Power Control

    Caelum User Manual Chapter 4. BIOS Configuration Settings 5�2�9 Power Control The Power Control page allows you to view and control the power of your server. To open Power Control, click Power Control from the menu bar. The various options of Power Control are given below.
  • Page 55: Chassis Identify Control

    Caelum User Manual Chapter 4. BIOS Configuration Settings 5�2�10 Chassis Identify Control The Chassis Identify Control page displays the BMC’s UID control information. Users can change the Identify LED behavior on this page. Click Chassis Identify Control from the menu bar. Select Off/On to control UID LED.
  • Page 56 Caelum User Manual Chapter 4. BIOS Configuration Settings Maintenance Description 1. Click Check All to backup the selected configuration items. The Backup Configuration page will appear Click Download Config to save the backup Backup file to the client system. Configuration 2.
  • Page 57: Sign Out

    Caelum User Manual Chapter 4. BIOS Configuration Settings 5�2�12 Sign out To log out of the BMC: Method 1: Click Sign out from the menu bar. The Logout dialog box will pop out. Cancel Method 2: Click the root quick button on the top right corner of the screen.
  • Page 58: Chapter 5� Technical Support

    Chapter 5� Technical Support Taiwain, Global Headquarters South California, United States Address: No� 152, Section 4, Address: 21808 Garcia Lane Linghang N� Rd, Dayuan District, City of Industry, CA 91789, Taoyuan City 337, Taiwan United States Tel: +886-3-433-9188 Toll free: +7-4997019998 Fax: +886-3-287-1818 Tel: +1-909-895-8989 Fax: +1-909-895-8989#157...