Kohler ENGLEFIELD K-78221X Installation And Care Manual page 10

Multi point electric shower
Table of Contents

Advertisement

Available languages

Available languages

Electrical Installation (cont.)
Insert the wall embedded cable
¨
through side entry "A" and lead
the cable to cable bracket "B".
Connect the cable as following:
¨
BROWN or RED --LIVE (L)
BLUE or BLACK --NEUTRAL (N)
GREEN or GREEN/YELLOW --EARTH (
BROWN
or RED
Clamp the cable to the correct position. Check if the wiring connection
¨
is correct and replace the cover.
When reinstalling the front cover, please take note of the procedure shown be-
low:
Ensure the position is correct, turn the VR shaft to OFF position (at the heater
¨
base).
Install the front cover, turn the temperature control knob to OFF position
¨
to align with the VR shaft. (at the front cover).
Press the upper part of the front of cover until it locks. Ensure the temperature
¨
control knob fix properly and screw the front cover to the heater base.
1287791-X2-C
BLUE or BLACK
GREEN
or GREEN/YELLOW
This position
10
A
B
)
This position
Kohler Co.